共 50 条
Solid-phase extraction in combination with dispersive liquid-liquid microextraction and ultra-high performance liquid chromatography-tandem mass spectrometry analysis: the ultra-trace determination of 10 antibiotics in water samples
被引:72
|作者:
Liang, Ning
[1
]
Huang, Peiting
[1
]
Hou, Xiaohong
[1
]
Li, Zhen
[1
]
Tao, Lei
[2
]
Zhao, Longshan
[2
]
机构:
[1] Shenyang Pharmaceut Univ, Sch Pharmaceut Engn, Shenyang 110016, Liaoning, Peoples R China
[2] Shenyang Pharmaceut Univ, Sch Pharm, Shenyang 110016, Liaoning, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Antibiotics;
Dispersive liquid-liquid microextraction;
Solid-phase extraction;
Ultra-high performance liquid chromatography-tandem mass spectrometry;
Water samples;
URBAN WASTE-WATER;
PHARMACEUTICALS;
METABOLITES;
OPTIMIZATION;
SULFONAMIDES;
GENOTOXICITY;
QUINOLONES;
RESIDUES;
MILK;
D O I:
10.1007/s00216-015-9284-z
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
A novel method, solid-phase extraction combined with dispersive liquid-liquid microextraction (SPE-DLLME), was developed for ultra-preconcentration of 10 antibiotics in different environmental water samples prior to ultra-high performance liquid chromatography-tandem mass spectrometry detection. The optimized results were obtained as follows: after being adjusted to pH 4.0, the water sample was firstly passed through PEP-2 column at 10 mL min(-1), and then methanol was used to elute the target analytes for the following steps. Dichloromethane was selected as extraction solvent, and methanol/acetonitrile (1:1, v/v) as dispersive solvent. Under optimal conditions, the calibration curves were linear in the range of 1-1000 ng mL(-1) (sulfamethoxazole, cefuroxime axetil), 5-1000 ng mL(-1) (tinidazole), 10-1000 ng mL(-1) (chloramphenicol), 2-1000 ng mL(-1) (levofloxacin oxytetracycline, doxycycline, tetracycline, and ciprofloxacin) and 1-400 ng mL(-1) (sulfadiazine) with a good precision. The LOD and LOQ of the method were at very low levels, below 1.67 and 5.57 ng mL(-1), respectively. The relative recoveries of the target analytes were in the range from 64.16 % to 99.80 % with relative standard deviations between 0.7 and 8.4 %. The matrix effect of this method showed a great decrease compared with solid-phase extraction and a significant value of enrichment factor (EF) compared with dispersive liquid-liquid microextraction. The developed method was successfully applied to the extraction and analysis of antibiotics in different water samples with satisfactory results.
引用
收藏
页码:1701 / 1713
页数:13
相关论文