X-ray detectors for NDE applications

被引:0
作者
Kroening, Michael [1 ]
Melkadze, Revaz G. [2 ]
Lezhneva, Tatiana M. [2 ]
Khvedelidze, Levan B. [2 ]
Kalandadze, Givi D. [2 ]
Baumbach, Tilo [3 ]
Berthold, Axel [1 ]
机构
[1] Fraunhofer Inst Non Destruct Testing, Maria Reiche Str 2, D-01109 Dresden, Germany
[2] Tbilisi State Univ, RPC Electron Technol, GE-0179 Tbilisi, Georgia
[3] Forschungszentrum Karlsruhe, Inst Synchrotron Radiat, D-76344 Eggenstein Leopoldshafen, Germany
来源
SENSOR SYSTEMS AND NETWORKS: PHENOMENA, TECHNOLOGY, AND APPLICATIONS FOR NDE AND HEALTH MONITORING 2007 | 2007年 / 6530卷
关键词
X-ray; detector; gallium arsenide; direct converting;
D O I
10.1117/12.717217
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
A tremendous development in the field of imaging radiation detectors has taken place in the last decade. Conventional X-ray film has been replaced by digital X-ray imaging systems in a number of ways. Such systems mainly consist of silicon charge coupled devices (CCDs) where incident photons create electron-hole pairs in the thin silicon absorption layer near the surface. In contrast to visible light, which is absorbed within a 2 gm layer of silicon, the penetration of X-ray is much deeper due to higher photon energy. This disadvantage is often circumvented by the use of a scintillator absorption layer. Due to scattering of the low energy fluorescence photons, resolution and contrast of the X-ray images decrease. In order to eliminate these disadvantages, hybrid detectors consisting of direct converting semiconductors and readout electronics parts are fabricated. For this configuration, it is advantageous that both parts can be optimized separately and different materials can be used. Because of the well developed technology, the readout chip is fabricated out of silicon. As absorbing material, silicon is less suitable. In a silicon substrate of 500 Lrn thickness, only 15% of a 30 keV radiation is absorbed and converted into charges. In order to increase the absorption, materials with a higher atomic mass have to be used. Several compound semiconductors can be used for this purpose. One of them is GaAs, which is available as high quality semiinsulating wafer material. For detector optimization, GaAs wafers from several manufacturers with different properties were investigated. Test structures with Schottky and PIN diodes were fabricated. The IN curves of the diodes, the spectral response from 5 up to 150 keV, the carrier concentration, and the carrier mobility were measured and compared. A survey of the results and the criteria for material selection resulting from these measurements will be provided in the paper.
引用
收藏
页数:8
相关论文
共 5 条
[1]   A prototype for a mammographic head and related developments [J].
Amendolia, SR ;
Annovazzi, A ;
Bigongiari, A ;
Bisogni, MG ;
Catarsi, F ;
Cesqui, F ;
Cetronio, A ;
Chianella, M ;
Delogu, P ;
Fantacci, ME ;
Galimberti, D ;
Lanzieri, C ;
Lavanga, S ;
Novelli, M ;
Passuello, G ;
Pieracci, M ;
Quattrocchi, M ;
Rosso, V ;
Stefanini, A ;
Testa, A ;
Venturelli, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2) :382-385
[2]   Semiconductor pixel detectors for digital mammography [J].
Novelli, M ;
Amendolia, SR ;
Bisogni, MG ;
Boscardin, M ;
Dalla Betta, GF ;
Delogu, P ;
Fantacci, ME ;
Quattrocchi, M ;
Rosso, V ;
Stefanini, A ;
Venturelli, L ;
Zucca, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3) :283-289
[3]   High resolution X-ray spectroscopy using a GaAs pixel detector [J].
Owens, A ;
Bavdaz, M ;
Peacock, A ;
Andersson, H ;
Nenonen, S ;
Krumrey, M ;
Puig, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 479 (2-3) :531-534
[4]  
SCHRODER DK, 1998, SEMICONDUCTOR MAT CH
[5]   Pixel detectors for particle physics and imaging applications [J].
Wermes, N .