Biomechanical analysis of the fixation systems for anterior column and posterior hemi-transverse acetabular fractures

被引:31
作者
Lei, Jianyin [1 ]
Dong, Pengfei [1 ]
Li, Zhiqiang [1 ]
Zhu, Feng [2 ]
Wang, Zhihua [1 ]
Cai, Xianhua [3 ]
机构
[1] Taiyuan Univ Technol, Inst Appl Mech & Biomed Engn, Taiyuan, Shanxi, Peoples R China
[2] Embry Riddle Aeronaut Univ, Dept Mech Engn, Daytona Beach, FL USA
[3] Wuhan Gen Hosp Guangzhou Command, Dept Orthoped, Wuhan, Hubei, Peoples R China
关键词
Acetabular; Anterior column and posterior hemi-transverse; Finite element analysis; Fixation system; Fracture; FINITE-ELEMENT-ANALYSIS; INTERNAL-FIXATION; WALL; REDUCTION; STABILITY;
D O I
10.1016/j.aott.2017.02.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The aim of this study was to evaluate the biomechanical properties of common fixation systems for complex acetabular fractures. Methods: A finite element (FE) pelvic model with anterior column and posterior hemi-transverse acetabular fractures was created. Three common fixation systems were used to fix the posterior wall acetabular fractures: 1. Anterior column plate combined with posterior column screws (group I), 2. Anterior column plate combined with quadrilateral area screws (group II) and 3. Double-column plates (group III). And 600 N, representing the body weight, was loaded on the upper surface of the sacrum to simulate the double-limb stance. The amounts of total and relative displacements were compared between the groups. Results: The total amount of displacement was 2.76 mm in group II, 2.81 mm in group III, and 2.83 mm in group I. The amount of relative displacement was 0.0078 mm in group II, 0.0093 mm in group III and 0.014 mm in group I. Conclusion: Our results suggested that all fixation systems enhance biomechanical stability significantly. Anterior column plate combined with quadrilateral area screws has quite comparable results to double column plates, they were superior to anterior column plate combined with posterior screws. (C) 2017 Turkish Association of Orthopaedics and Traumatology. Publishing services by Elsevier B.V.
引用
收藏
页码:248 / 253
页数:6
相关论文
共 26 条
[1]   Modified Stoppa Approach for Acetabular Fractures With Anterior and Posterior Column Displacement: Quantification of Radiographic Reduction and Analysis of Interobserver Variability [J].
Andersen, Romney C. ;
O'Toole, Robert V. ;
Nascone, Jason W. ;
Sciadini, Marcus F. ;
Frisch, H. Michael ;
Turen, Clifford W. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (05) :271-278
[2]  
Anderson AE, 2004, P COMP METH BIOM BIO
[3]   Outcomes of acetabular fracture fixation with ten years' follow-up [J].
Briffa, N. ;
Pearce, R. ;
Hill, A. M. ;
Bircher, M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (02) :229-236
[4]   Development of a finite element model of the upper cervical spine and a parameter study of ligament characteristics [J].
Brolin, K ;
Halldin, P .
SPINE, 2004, 29 (04) :376-385
[5]  
COLE JD, 1994, CLIN ORTHOP RELAT R, P112
[6]   DEVELOPMENT AND VALIDATION OF A 3-DIMENSIONAL FINITE-ELEMENT MODEL OF THE PELVIC BONE [J].
DALSTRA, M ;
HUISKES, R ;
VANERNING, L .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (03) :272-278
[7]   LOAD-TRANSFER ACROSS THE PELVIC BONE [J].
DALSTRA, M ;
HUISKES, R .
JOURNAL OF BIOMECHANICS, 1995, 28 (06) :715-724
[8]   Open Treatment of Pelvic and Acetabular Fractures [J].
Gettys, F. Keith ;
Russell, George V. ;
Karunakar, Madhav A. .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2011, 42 (01) :69-+
[9]   Biomechanical Analysis of Acetabular Revision Constructs Is Pelvic Discontinuity Best Treated With Bicolumnar or Traditional Unicolumnar Fixation? [J].
Gililland, Jeremy M. ;
Anderson, Lucas A. ;
Henninger, Heath B. ;
Kubiak, Erik N. ;
Peters, Christopher L. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (01) :178-186
[10]  