NERVE CONDUCTION STUDIES ARE SAFE IN PATIENTS WITH CENTRAL VENOUS CATHETERS

被引:2
作者
London, Zachary N. [1 ]
Mundwiler, Andrew [2 ]
Oral, Hakan [3 ]
Gallagher, Gary W. [1 ]
机构
[1] Univ Michigan, Dept Neurol, 1324 Taubman Ctr,1500 E Med Ctr Dr, Ann Arbor, MI 48109 USA
[2] Spectrum Hlth, Dept Neurol, Grand Rapids, MI USA
[3] Univ Michigan, Dept Internal Med, Div Cardiol, Ann Arbor, MI 48109 USA
关键词
arrhythmia; cardiac conduction; central venous catheters; electromyography; nerve conduction studies; safety; STIMULATION; HAZARDS; DEVICES;
D O I
10.1002/mus.25497
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction: It is unknown if central venous catheters bypass the skin's electrical resistance and engender a risk of nerve conduction study-induced cardiac arrhythmia. The objective of this study is to determine if nerve conduction studies affect cardiac conduction and rhythm in patients with central venous catheters. Methods: Under continuous 12-lead electrocardiogram monitoring, subjects with and without central venous catheters underwent a series of upper extremity nerve conduction studies. A cardiologist reviewed the electrocardiogram tracings for evidence of cardiac conduction abnormality or arrhythmia. Results: Ten control subjects and 10 subjects with central venous catheters underwent the nerve conduction study protocol. No malignant arrhythmias or conduction abnormalities were noted in either group. Conclusions: Nerve conduction studies of the upper extremities, including both proximal stimulation and repetitive stimulation, do not appear to confer increased risk of cardiac conduction abnormality in those patients with central venous catheters who are not critically ill or have a prior history of arrhythmia.
引用
收藏
页码:321 / 323
页数:3
相关论文
共 10 条
  • [1] Iatrogenic complications and risks of nerve conduction studies and needle electromyography
    Al-Shekhlee, A
    Shapiro, BE
    Preston, DC
    [J]. MUSCLE & NERVE, 2003, 27 (05) : 517 - 526
  • [2] [Anonymous], 2014, CANNON TM 2 PLUS
  • [3] Safety of repetitive nerve stimulation in patients with cardiac implantable electronic devices
    Cronin, Edmond M.
    Gray, Jennifer
    Abi-Saleh, Bernard
    Wilkoff, Bruce L.
    Levin, Kerry H.
    [J]. MUSCLE & NERVE, 2013, 47 (06) : 840 - 844
  • [4] LABAN MM, 1988, ARCH PHYS MED REHAB, V69, P358
  • [5] THRESHOLDS OF FIBRILLATING LEAKAGE CURRENTS ALONG INTRACARDIAC CATHETERS - EXPERIMENTAL STUDY
    LEE, WR
    SCOTT, JR
    [J]. CARDIOVASCULAR RESEARCH, 1973, 7 (04) : 495 - 500
  • [6] SAFETY OF NERVE CONDUCTION STUDIES IN PATIENTS WITH PERIPHERAL INTRAVENOUS LINES
    Mellion, Michelle L.
    Buxton, Alfred E.
    Iyer, Venkat
    Almahameed, Soufian
    Lorvidhaya, Peem
    Gilchrist, James M.
    [J]. MUSCLE & NERVE, 2010, 42 (02) : 189 - 191
  • [7] ELECTROCUTION HAZARDS WITH TRANSVENOUS PACEMAKER ELECTRODES
    MERKEL, R
    SOVIE, MD
    [J]. AMERICAN JOURNAL OF NURSING, 1968, 68 (12) : 2560 - 2563
  • [8] A MESSAGE FROM THE GROUND ELECTRODE
    Robinson, Lawrence R.
    Christie, Michael
    Nandedkar, Sanjeev
    [J]. MUSCLE & NERVE, 2016, 54 (06) : 1010 - 1011
  • [9] Safety of nerve conduction studies in patients with implanted cardiac devices
    Schoeck, Andreas P.
    Mellion, Michelle L.
    Gilchrist, James M.
    Christian, Fredric V.
    [J]. MUSCLE & NERVE, 2007, 35 (04) : 521 - 524
  • [10] ELECTRICAL HAZARDS AND CARDIOVASCULAR FUNCTION
    STARMER, CF
    MCINTOSH, HD
    WHALEN, RE
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1971, 284 (04) : 181 - &