Ten to fifteen-year clinical and radiographic follow-up with a third-generation cementless stem in a young patient population

被引:10
|
作者
Studers, Peteris [1 ]
Belajevs, Danils [1 ]
Jurkevics, Vitolds [1 ]
Likums, Peteris [1 ]
机构
[1] Riga Stradins Univ, Latvian State Hosp Traumatol & Orthopaed, Dept Orthopaed Surg, Duntes Iela 12-22, Riga, Latvia
关键词
Osteoarthritis; Total hip replacement; Long-term outcome; Survival analysis; TOTAL HIP-ARTHROPLASTY; OSTEOARTHRITIS OUTCOME SCORE; METAL-ON-METAL; FEMORAL COMPONENT; THREADED CUP; CERAMIC BEARINGS; 10-YEAR; 2ND-GENERATION; REPLACEMENT; REGISTER;
D O I
10.1007/s00264-015-2846-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Outcome data beyond 11 years of follow-up is not available for the third-generation Zweymuller femoral stem in combination with a polyethylene bearing. We report ten to 15-year results with this total hip arthroplasty (THA) combination in a young population. Methods A retrospective, observational, non-randomised, single-centre, clinical observational study was conducted in which 311 primary THAs were performed in 276 patients between 1996 and 2000 using a third-generation Zweymuller stem. The mean age of the patients at operation was 47.4 years (range 18-77 years). Results Stem survival for any reason was 93.5 % after ten years and 89.6 % after 13 years, and the probability of aseptic stem loosening was 98.7 % at both ten and 13 years. The occurrence of femoral radiolucent lines was low, at just 17.2 %. Minor femoral osteolysis was identified in 30 % of patients and was attributed to polyethylene liner wear. Clinical and patient satisfaction outcomes were in line with previous investigations, and the rate of adverse events was low. Conclusions The third-generation Zweymuller stem shows good radiographic and clinical results and good longevity, including in the younger osteoarthritic patient. The use of low-wear bearings may further reduce the rate of osteolysis and wear-related revision in young and active patients.
引用
收藏
页码:465 / 471
页数:7
相关论文
共 50 条
  • [41] Reverse shoulder arthroplasty in young patient with achondroplasia - Ten year follow up: Case report
    van den Broek, M.
    Verborgt, O.
    Declercq, G.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (07) : 1127 - 1130
  • [42] Femoral revision in total hip arthroplasty using a cementless modular stem: clinical and radiological results with a 8-year follow-up
    Spranz, David
    Skrobek, David
    Randoll, Jannis
    Kinkel, Stefan
    Merle, Christian
    Walker, Tilman
    Renkawitz, Tobias
    Reiner, Tobias
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (03) : 1369 - 1377
  • [43] Clinical and radiological outcomes of cervical disc arthroplasty: ten year follow-up study
    Song, Qingpeng
    He, Da
    Han, Xiao
    Zhang, Ning
    Wang, Jinchao
    Tian, Wei
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (10) : 2389 - 2396
  • [44] Long-term clinical and radiographic results of cementless total hip arthroplasty for patients with rheumatoid arthritis: minimal 10-year follow-up
    Matsushita, Isao
    Morita, Yuji
    Ito, Yoshiaki
    Motomura, Hiraku
    Kimura, Tomoatsu
    MODERN RHEUMATOLOGY, 2014, 24 (02) : 281 - 284
  • [45] Cementless titanium tapered-wedge femoral stem - 10-to 15-year follow-up
    Marshall, AD
    Mokris, JG
    Reitman, RD
    Dandar, A
    Mauerhan, DR
    JOURNAL OF ARTHROPLASTY, 2004, 19 (05) : 546 - 552
  • [46] Third-generation posterior-stabilised cemented system for total knee arthroplasty: Survivorship and outcomes after 20-year follow-up
    Contreras, Jose Luis Patino
    Perez, Victoria Sebastian
    Antonio, Checa Garcia
    Jorge, Montejo Sancho
    Javier, Martinez Martin
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [47] Minimum 5-year Follow-up for Primary THA Using a Tapered, Proximally Coated Cementless Stem
    Kolisek, Frank R.
    Issa, Kimona
    Harwin, Steven F.
    Jaggard, Charles
    Naziri, Qais
    Mont, Michael A.
    ORTHOPEDICS, 2013, 36 (05) : E633 - E636
  • [48] Clinical and Radiographic Results for the Richards Modular Hip System Prosthesis in Total Hip Arthroplasty Average 10-Year Follow-Up
    Suehara, Hiroshi
    Fujioka, Mikihiro
    Inoue, Shigehiro
    Takahashi, Kenji
    Ueshima, Keiichiro
    Kubo, Toshikazu
    JOURNAL OF ARTHROPLASTY, 2010, 25 (03) : 369 - 374
  • [49] Clinical and radiographic outcomes after total hip arthroplasty with the NANOS neck preserving hip stem: a 10 to 16-year follow-up study
    De Santis, Vincenzo
    Bonfiglio, Nadia
    Basilico, Mattia
    Germani, Greta Tanzi
    Matrangolo, Maria Rosaria
    Carosini, Angelo
    Malerba, Giuseppe
    Maccauro, Giulio
    BMC MUSCULOSKELETAL DISORDERS, 2022, 22 (SUPPL 2)
  • [50] Straight Tapered Titanium Stem With Alumina Bearing in Cementless Primary Total Hip Arthroplasty A Minimum 5-Year Follow-Up
    Hwang, Bo-Hyun
    Lee, Woo-Suk
    Park, Kwan-Kyu
    Yang, Ick-Hwan
    Han, Chang-Dong
    JOURNAL OF ARTHROPLASTY, 2011, 26 (08) : 1310 - 1317