Ten to fifteen-year clinical and radiographic follow-up with a third-generation cementless stem in a young patient population

被引:10
|
作者
Studers, Peteris [1 ]
Belajevs, Danils [1 ]
Jurkevics, Vitolds [1 ]
Likums, Peteris [1 ]
机构
[1] Riga Stradins Univ, Latvian State Hosp Traumatol & Orthopaed, Dept Orthopaed Surg, Duntes Iela 12-22, Riga, Latvia
关键词
Osteoarthritis; Total hip replacement; Long-term outcome; Survival analysis; TOTAL HIP-ARTHROPLASTY; OSTEOARTHRITIS OUTCOME SCORE; METAL-ON-METAL; FEMORAL COMPONENT; THREADED CUP; CERAMIC BEARINGS; 10-YEAR; 2ND-GENERATION; REPLACEMENT; REGISTER;
D O I
10.1007/s00264-015-2846-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Outcome data beyond 11 years of follow-up is not available for the third-generation Zweymuller femoral stem in combination with a polyethylene bearing. We report ten to 15-year results with this total hip arthroplasty (THA) combination in a young population. Methods A retrospective, observational, non-randomised, single-centre, clinical observational study was conducted in which 311 primary THAs were performed in 276 patients between 1996 and 2000 using a third-generation Zweymuller stem. The mean age of the patients at operation was 47.4 years (range 18-77 years). Results Stem survival for any reason was 93.5 % after ten years and 89.6 % after 13 years, and the probability of aseptic stem loosening was 98.7 % at both ten and 13 years. The occurrence of femoral radiolucent lines was low, at just 17.2 %. Minor femoral osteolysis was identified in 30 % of patients and was attributed to polyethylene liner wear. Clinical and patient satisfaction outcomes were in line with previous investigations, and the rate of adverse events was low. Conclusions The third-generation Zweymuller stem shows good radiographic and clinical results and good longevity, including in the younger osteoarthritic patient. The use of low-wear bearings may further reduce the rate of osteolysis and wear-related revision in young and active patients.
引用
收藏
页码:465 / 471
页数:7
相关论文
共 50 条
  • [1] Ten to fifteen-year clinical and radiographic follow-up with a third-generation cementless stem in a young patient population
    Peteris Studers
    Danils Belajevs
    Vitolds Jurkevics
    Peteris Likums
    International Orthopaedics, 2016, 40 : 465 - 471
  • [2] The C-Stem in Clinical Practice Fifteen-Year Follow-Up of a Triple Tapered Polished Cemented Stem
    Purbach, Bodo
    Kay, Peter R.
    Siney, Paul D.
    Fleming, Patricia A.
    Wroblewski, B. Michael
    JOURNAL OF ARTHROPLASTY, 2013, 28 (08) : 1367 - 1371
  • [3] Cementless Modular Total Hip Arthroplasty in Patients Younger than Fifty with Femoral Head Osteonecrosis: Minimum Fifteen-Year Follow-Up
    Kim, Sang-Min
    Lim, Seung-Jae
    Moon, Young-Wan
    Kim, Yang-Tae
    Ko, Kyung-Rae
    Park, Youn-Soo
    JOURNAL OF ARTHROPLASTY, 2013, 28 (03) : 504 - 509
  • [4] A cementless elastic monoblock socket in young patients: a ten to 18-year clinical and radiological follow-up
    Pakvis, Dean
    Biemond, Liesbeth
    van Hellemondt, Gijs
    Spruit, Maarten
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (10) : 1445 - 1451
  • [5] Accelerated polyethylene wear and early failure of the uncemented Reflection acetabular component: a ten to fifteen-year follow-up study
    Clement, Nicholas D.
    Mitchell, Martin
    Trayner, Morag E.
    Porter, Daniel E.
    Lawson, Graham M.
    Burnett, Richard
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (12) : 2337 - 2343
  • [6] Long-term clinical and radiographic results of the cementless Spotorno stem in Japanese patients: A more than 15-year follow-up
    Zang, Junting
    Uchiyama, Katsufumi
    Moriya, Mitsutoshi
    Li, Zhengwei
    Fukushima, Kensuke
    Yamamoto, Takeaki
    Takahira, Naonobu
    Takaso, Masashi
    Liu, Jianguo
    Feng, Wei
    JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (01):
  • [7] Third-Generation Alumina-on-Alumina Total Hip Arthroplasty: 14 to 16-Year Follow-Up Study
    Kang, Bun-Jung
    Ha, Yong-Chan
    Ham, Dae-Woong
    Hwang, Sun-Chul
    Lee, Young-Kyun
    Koo, Kyung-Hoi
    JOURNAL OF ARTHROPLASTY, 2015, 30 (03) : 411 - 415
  • [8] Accelerated polyethylene wear and early failure of the uncemented Reflection acetabular component: a ten to fifteen-year follow-up study
    Nicholas D. Clement
    Martin Mitchell
    Morag E. Trayner
    Daniel E. Porter
    Graham M. Lawson
    Richard Burnett
    International Orthopaedics, 2013, 37 : 2337 - 2343
  • [9] Ten-year follow-up of a cemented tapered stem
    Klasan, Antonio
    Sen, Ahmet
    Dworschak, Philipp
    El-Zayat, Bilal Farouk
    Ruchholtz, Steffen
    Schuettler, Karl F.
    Schmitt, Jan
    Heyse, Thomas J.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (09) : 1317 - 1322
  • [10] Fifteen-year follow-up of Italian families affected by arginine glycine amidinotransferase deficiency
    Battini, Roberta
    Alessandri, M. Grazia
    Casalini, Claudia
    Casarano, Manuela
    Tosetti, Michela
    Cioni, Giovanni
    ORPHANET JOURNAL OF RARE DISEASES, 2017, 12 : 1 - 9