Whole-Brain Adaptive 70-kVp Perfusion Imaging with Variable and Extended Sampling Improves Quality and Consistency While Reducing Dose

被引:22
作者
Corcuera-Solano, I. [1 ]
McLellan, A. M. [1 ]
Doshi, A. H. [1 ]
Pawha, P. S. [1 ]
Tanenbaum, L. N. [1 ]
机构
[1] Mt Sinai Med Ctr, Dept Neuroradiol, New York, NY 10029 USA
关键词
ACUTE ISCHEMIC-STROKE; TEMPORAL RESOLUTION; CT PARAMETERS; EXPOSURE; VOLUME; HEAD;
D O I
10.3174/ajnr.A4043
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Despite common use of CTP to assess cerebral hemodynamics in the setting of ischemia, concerns over radiation exposure remain. Our aim was to evaluate the efficacy of an adaptive 70-kVp (peak) whole-brain CTP protocol with variable sampling intervals and extended duration against an established fixed-sampling, limited-period protocol at 80 kVp. MATERIALS AND METHODS: A retrospective analysis of 37 patients with stroke scanned with conventional (n = 17) and variant-protocol (n = 20) whole-brain CTP was performed. We compared radiation dose, parametric map quality, and consistency of full-contrast circulation capture between a modified 70-kVp protocol, with 20 whole-brain passes at variable sampling intervals over an extended sampling period, and a conventional 80-kVp CTP examination with 24 passes at fixed-sampling intervals and a more limited scanning window. Mann-Whitney U test analysis was used to compare both protocols. RESULTS: The 70-kVp CTP scan provided superior image quality at a 45% lower CT dose index volume and 13% lower dose-length product/effective dose compared with the conventional 80-kVp scan. With respect to the consistency of contrast-passage capture, 95% of the adaptive, extended protocol continued through the venous return to baseline, compared with only 47% by using the conventional limited-length protocol. Rapid sampling during the critical arterial arrival and washout period was accomplished in nearly 95% with both the variable and fixed-sampling-interval protocols. CONCLUSIONS: Seventy-kilovolt (peak) CTP with variable and extended sampling produces improved image quality at lower radiation doses with greater consistency of full contrast passage capture.
引用
收藏
页码:2045 / 2051
页数:7
相关论文
共 21 条
[1]   CT Perfusion in Acute Ischemic Stroke: A Comparison of 2-Second and 1-Second Temporal Resolution [J].
Abels, B. ;
Klotz, E. ;
Tomandl, B. F. ;
Villablanca, J. P. ;
Kloska, S. P. ;
Lell, M. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (09) :1632-1639
[2]  
Bogartz G., 2004, EUROPEAN GUIDELINES
[3]  
Cohnen M, 2000, AM J NEURORADIOL, V21, P1654
[4]   Dose Exposure of Patients Undergoing Comprehensive Stroke Imaging by Multidetector-Row CT: Comparison of 320-Detector Row and 64-Detector Row CT Scanners [J].
Diekmann, S. ;
Siebert, E. ;
Juran, R. ;
Roll, M. ;
Deeg, W. ;
Bauknecht, H. -C. ;
Diekmann, F. ;
Klingebiel, R. ;
Bohner, G. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (06) :1003-1009
[5]   Deconvolution-Based CT and MR Brain Perfusion Measurement: Theoretical Model Revisited and Practical Implementation Details [J].
Fieselmann, Andreas ;
Kowarschik, Markus ;
Ganguly, Arundhuti ;
Hornegger, Joachim ;
Fahrig, Rebecca .
INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2011, 2011
[6]  
Hirata Masaaki, 2005, Radiat Med, V23, P351
[7]  
Hirata Masaaki, 2005, Radiat Med, V23, P97
[8]   Patient size and x-ray technique factors in head computed tomography examinations. II. Image quality [J].
Huda, W ;
Lieberman, KA ;
Chang, J ;
Roskopf, ML .
MEDICAL PHYSICS, 2004, 31 (03) :595-601
[9]   Radiation-induced temporary hair loss as a radiation damage only occurring in patients who had the combination of MDCT and DSA [J].
Imanishi, Y ;
Fukui, A ;
Niimi, H ;
Itoh, D ;
Nozaki, K ;
Nakaji, S ;
Ishizuka, K ;
Tabata, H ;
Furuya, Y ;
Uzura, M ;
Takahama, H ;
Hashizume, S ;
Arima, S ;
Nakajima, Y .
EUROPEAN RADIOLOGY, 2005, 15 (01) :41-46
[10]   Dynamic perfusion CT Optimizing the temporal resolution for the calculation of perfusion CT parameters in stroke patients [J].
Kaemena, Andreas ;
Streitparth, Florian ;
Grieser, Christian ;
Lehrnkuhl, Lukas ;
Jamil, Basil ;
Wojtal, Katarzyna ;
Ricke, Jens ;
Pech, Maciej .
EUROPEAN JOURNAL OF RADIOLOGY, 2007, 64 (01) :111-118