Performance evaluation and microstructural characterization of GFRP bars in seawater-contaminated concrete

被引:67
作者
El-Hassan, Hilal [1 ]
El-Maaddawy, Tamer [1 ]
Al-Sallamin, Abdelrahman [1 ]
Al-Saidy, Abdullah [2 ]
机构
[1] UAE Univ, Dept Civil & Environm Engn, POB 15551, Al Ain, U Arab Emirates
[2] Sultan Qaboos Univ, Dept Civil & Architectural Engn, POB 33, Muscat, Oman
关键词
Durability performance; GFRP; Tensile strength; Microstructure; Seawater; Concrete; LONG-TERM DURABILITY; REINFORCING BARS; TENSILE PROPERTIES; SEVERE ENVIRONMENTS; REBAR;
D O I
10.1016/j.conbuildmat.2017.04.135
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper aims to investigate the durability performance and microstructure characteristics of two different types of commercially-produced glass fiber-reinforced polymer (GFRP) bars conditioned in moist seawater-contaminated concrete. GFRP bars encased in seawater-contaminated concrete were immersed in tap water for 5, 10, and 15 months at temperatures of 20, 40, and 60 degrees C. Following conditioning, the GFRP bars were retrieved then tested to failure under uniaxial tension. Microstructure analysis was performed by employing differential scanning calorimetry (DSC), Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM), and matrix digestion using nitric acid. Type I GFRP bars, with the lower moisture uptake, exhibited insignificant strength reductions in the range of 2-15% whereas Type II, with the higher moisture uptake, exhibited substantial strength reductions in the range of 19-50%. Type II GFRP bars featured lower matrix retention and developed higher hydroxyl ions during conditioning than those of their Type I counterparts. The extent of degradation was more sensitive to the conditioning temperature rather than conditioning duration. A decrease in the glass transition temperature (T-g) of both types of GFRP bars was recorded, indicating matrix plasticization. Results of SEM highlighted matrix disintegration and fiber debonding after conditioning. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:66 / 78
页数:13
相关论文
共 41 条
  • [1] Aashto (American Association of State Highway and Transportation Officials), 2014, TP95 AASHTO
  • [2] DEGRADATION OF CROSSLINKED RESINS IN WATER AND ELECTROLYTE-SOLUTIONS
    ABEYSINGHE, HP
    EDWARDS, W
    PRITCHARD, G
    SWAMPILLAI, GJ
    [J]. POLYMER, 1982, 23 (12) : 1785 - 1790
  • [3] ACI Committee, 2012, 4403R12 ACI COMM
  • [4] Effect of harsh environmental conditions on the tensile properties of GFRP bars
    Al-Salloum, Yousef A.
    El-Gamal, Sherif
    Almusallam, Tarek H.
    Alsayed, Saleh H.
    Aqel, Mohammed
    [J]. COMPOSITES PART B-ENGINEERING, 2013, 45 (01) : 835 - 844
  • [5] Durability of GFRP rebars in concrete beams under sustained loads at severe environments
    Almusallam, TH
    Al-Salloum, YA
    [J]. JOURNAL OF COMPOSITE MATERIALS, 2006, 40 (07) : 623 - 637
  • [6] [Anonymous], 2020, STANDARD TEST METHOD
  • [7] [Anonymous], 2016, C597 ASTM
  • [8] [Anonymous], 2015, 4401R15 ACI COMM
  • [9] [Anonymous], 2010, D570 ASTM
  • [10] [Anonymous], 2011, Standard Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens, DOI [10.1520/C0496_C0496M-11, DOI 10.1520/C0496_C0496M-17]