Wavelet denoising for quantum noise removal in chest digital tomosynthesis

被引:8
作者
Gomi, Tsutomu [1 ]
Nakajima, Masahiro [2 ]
Umeda, Tokuo [1 ]
机构
[1] Kitasato Univ, Sch Allied Hlth Sci, Sagamihara, Kanagawa 2520373, Japan
[2] Hosoda Clin, Tokyo, Japan
关键词
Digital tomosynthesis; Wavelet; Denoising; Quantum noise; Chest imaging; RADIOGRAPHIC RECONSTRUCTION METHOD; BASIC IMAGING PROPERTIES; OF-PLANE STRUCTURES; DOSE REDUCTION; SYSTEMS; ECTOMOGRAPHY; PERFORMANCE; SIMULATION; SHRINKAGE; DENSITY;
D O I
10.1007/s11548-014-1003-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Quantum noise impairs image quality in chest digital tomosynthesis (DT). A wavelet denoising processing algorithm for selectively removing quantum noise was developed and tested. A wavelet denoising technique was implemented on a DT system and experimentally evaluated using chest phantom measurements including spatial resolution. Comparison was made with an existing post-reconstruction wavelet denoising processing algorithm reported by Badea et al. (Comput Med Imaging Graph 22:309-315, 1998). The potential DT quantum noise decrease was evaluated using different exposures with our technique (pre-reconstruction and post-reconstruction wavelet denoising processing via the balance sparsity-norm method) and the existing wavelet denoising processing algorithm. Wavelet denoising processing algorithms such as the contrast-to-noise ratio (CNR), root mean square error (RMSE) were compared with and without wavelet denoising processing. Modulation transfer functions (MTF) were evaluated for the in-focus plane. We performed a statistical analysis (multi-way analysis of variance) using the CNR and RMSE values. Our wavelet denoising processing algorithm significantly decreased the quantum noise and improved the contrast resolution in the reconstructed images (CNR and RMSE: pre-balance sparsity-norm wavelet denoising processing versus existing wavelet denoising processing, ; post-balance sparsity-norm wavelet denoising processing versus existing wavelet denoising processing, ; CNR: with versus without wavelet denoising processing, ). The results showed that although MTF did not vary (thus preserving spatial resolution), the existing wavelet denoising processing algorithm caused MTF deterioration. A balance sparsity-norm wavelet denoising processing algorithm for removing quantum noise in DT was demonstrated to be effective for certain classes of structures with high-frequency component features. This denoising approach may be useful for a variety of clinical applications for chest digital tomosynthesis when quantum noise is present.
引用
收藏
页码:75 / 86
页数:12
相关论文
共 37 条
  • [11] INVESTIGATION OF BASIC IMAGING PROPERTIES IN DIGITAL RADIOGRAPHY .9. EFFECT OF DISPLAYED GRAY LEVELS ON SIGNAL-DETECTION
    GIGER, ML
    OHARA, K
    DOI, K
    [J]. MEDICAL PHYSICS, 1986, 13 (03) : 312 - 318
  • [12] Numerical performance of block thresholded wavelet estimators
    Hall, P
    Penev, S
    Kerkyacharian, G
    Picard, D
    [J]. STATISTICS AND COMPUTING, 1997, 7 (02) : 115 - 124
  • [13] Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors
    Kasap, Safa
    Frey, Joel B.
    Belev, George
    Tousignant, Olivier
    Mani, Habib
    Greenspan, Jonathan
    Laperriere, Luc
    Bubon, Oleksandr
    Reznik, Alla
    DeCrescenzo, Giovanni
    Karim, Karim S.
    Rowlands, John A.
    [J]. SENSORS, 2011, 11 (05) : 5112 - 5157
  • [14] ECTOMOGRAPHY - A NEW RADIOGRAPHIC RECONSTRUCTION METHOD .1. THEORY AND ERROR ESTIMATES
    KNUTSSON, HE
    EDHOLM, P
    GRANLUND, GH
    PETERSSON, CU
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (11) : 640 - 648
  • [15] A wavelet shrinkage approach to tomographic image reconstruction
    Kolaczyk, ED
    [J]. JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1996, 91 (435) : 1079 - 1090
  • [16] A METHOD FOR SELECTIVE REMOVAL OF OUT-OF-PLANE STRUCTURES IN DIGITAL TOMOSYNTHESIS
    KOLITSI, Z
    PANAYIOTAKIS, G
    PALLIKARAKIS, N
    [J]. MEDICAL PHYSICS, 1993, 20 (01) : 47 - 50
  • [17] INVESTIGATION OF BASIC IMAGING PROPERTIES IN DIGITAL RADIOGRAPHY .10. STRUCTURE MOTTLE OF II-TV DIGITAL IMAGING-SYSTEMS
    KUME, Y
    DOI, K
    OHARA, K
    GIGER, ML
    [J]. MEDICAL PHYSICS, 1986, 13 (06) : 843 - 849
  • [18] Comparison of chest digital tomosynthesis and chest radiography for detection of asbestos-related pleuropulfnonary disease
    Lee, G.
    Jeong, Y. J.
    Kim, K. I.
    Song, J. W.
    Kang, D. M.
    Kim, Y. D.
    Lee, J. W.
    [J]. CLINICAL RADIOLOGY, 2013, 68 (04) : 376 - 382
  • [19] CHARACTERIZATION OF SIGNALS FROM MULTISCALE EDGES
    MALLAT, S
    ZHONG, S
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (07) : 710 - 732
  • [20] Mathworks Inc, 2011, WAV TOOLB