Reliability and validity of measurements of facial swelling with a stereophotogrammetry optical three-dimensional scanner

被引:50
作者
van der Meer, Wicher J. [1 ]
Dijkstra, Pieter U. [2 ,3 ]
Visser, Anita [2 ]
Vissink, Arjan [2 ]
Ren, Yijin [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Orthodont, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Oral & Maxillofacial Surg, NL-9700 RB Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Ctr Rehabil, Dept Rehabil, Groningen, Netherlands
关键词
3dMD DSP400 (R) stereo-optical 3D scanner; 3D stereophotogrammetry; swelling; measurement; reliability; IMAGING-SYSTEMS; SOFT-TISSUE; PRECISION; ACCURACY; REPRODUCIBILITY; SURGERY; IMAGES; BREAST;
D O I
10.1016/j.bjoms.2014.08.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Volume changes in facial morphology can be assessed using the 3dMD DSP400 (R) stereo-optical 3-dimensional scanner, which uses visible light and has a short scanning time. Its reliability and validity have not to our knowledge been investigated for the assessment of facial swelling. Our aim therefore was to assess them for measuring changes in facial contour, in vivo and in vitro. Twenty-four healthy volunteers with and without an artificial swelling of the cheek were scanned, twice in the morning and twice in the afternoon (in vivo measurements). A mannequin head was scanned 4 times with and without various externally applied artificial swellings (in vitro measurements). The changes in facial contour caused by the artificial swelling were measured as the change in volume of the cheek (with and without artificial swelling in place) using 3dMD Vultus (R) software. In vivo and in vitro reliability expressed in intraclass correlations were 0.89 and 0.99, respectively. In vivo and in vitro repeatability coefficients were 5.9 and 1.3 ml, respectively. The scanner underestimated the volume by 1.2 ml (95% CI -0.9 to 3.4) in vivo and 0.2 ml (95% CI 0.02 to 0.4) in vitro. The 3dMD stereophotogrammetry scanner is a valid and reliable tool to measure volumetric changes in facial contour of more than 5.9 ml and for the assessment of facial swelling. (C) 2014 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:922 / 927
页数:6
相关论文
共 26 条
[1]   Precision and error of three-dimensional phenotypic measures acquired from 3dMD photogrammetric images [J].
Aldridge, K ;
Boyadjiev, SA ;
Capone, GT ;
DeLeon, VB ;
Richtsmeier, JT .
AMERICAN JOURNAL OF MEDICAL GENETICS PART A, 2005, 138A (03) :247-253
[2]   BIOSTEREOMETRIC ANALYSIS OF SURGICALLY CORRECTED ABNORMAL FACES [J].
BERKOWITZ, S ;
CUZZI, J .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1977, 72 (05) :526-538
[3]   A PHOTOGRAMMETRIC METHOD OF MEASURING THE VOLUME OF FACIAL SWELLINGS [J].
BJORN, H ;
LUNDQVIST, C ;
HJELMSTROM, P .
JOURNAL OF DENTAL RESEARCH, 1954, 33 (03) :295-308
[4]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[5]   OBJECTIVE MEASUREMENT OF POSTOPERATIVE SWELLING [J].
BREYTENBACH, HS .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1978, 7 (04) :386-392
[6]   REPRODUCIBILITY OF NATURAL HEAD POSITION [J].
CHIU, CSW ;
CLARK, RKF .
JOURNAL OF DENTISTRY, 1991, 19 (02) :130-131
[7]  
Day Christian J, 2006, World J Orthod, V7, P15
[8]  
de Vet HC, 2011, MEASUREMENT MED PRAC
[9]   Evaluation of Precision and Accuracy Assessment of Different 3-D Surface Imaging Systems for Biomedical Purposes [J].
Eder, Maximilian ;
Brockmann, Gernot ;
Zimmermann, Alexander ;
Papadopoulos, Moschos A. ;
Schwenzer-Zimmerer, Katja ;
Zeilhofer, Hans Florian ;
Sader, Robert ;
Papadopulos, Nikolaos A. ;
Kovacs, Laszlo .
JOURNAL OF DIGITAL IMAGING, 2013, 26 (02) :163-172
[10]   Volume Measurement Using the Polhemus FastSCAN 3D Laser Scanning: A Novel Application for Burns Clinical Research [J].
Edgar, Dale ;
Day, Rob ;
Briffa, N. Kathy ;
Cole, Joan ;
Wood, Fiona .
JOURNAL OF BURN CARE & RESEARCH, 2008, 29 (06) :994-1000