Characterization of Inorganic Elements within PM2.5 and PM10 Fractions of Fly Ashes from Coal-Fired Power Plants

被引:25
作者
Li, Zhiyong [1 ]
Ji, Yaqin [2 ]
Ma, Huiqiao [1 ]
Zhao, Peng [1 ]
Zeng, Xiangchao [1 ]
Liu, Songtao [1 ]
Jiang, Yunjun [3 ]
Wang, Lei [1 ,3 ]
Liu, Aiqin [3 ]
Gao, Huiying [1 ]
Liu, Fude [4 ]
Mwangi, John Kennedy [5 ,6 ]
机构
[1] North China Elect Power Univ, Sch Environm Sci & Engn, Baoding 071000, Peoples R China
[2] Nankai Univ, Sch Environm Sci & Engn, Tianjin 300071, Peoples R China
[3] Cent Lab Geol & Mineral Resources Hebei Prov, Baoding 071003, Peoples R China
[4] Tianjin Univ Technol, Sch Environm Sci & Safety Engn, Tianjin 300384, Peoples R China
[5] Hefei Univ Technol, Sch Resources & Environm Engn, Hefei 230009, Peoples R China
[6] Natl Cheng Kung Univ, Dept Environm Engn, Tainan 70101, Taiwan
基金
中国国家自然科学基金;
关键词
Coal-fired power plant; Inorganic elements; Fly ash; PM2.5; PM10; FLUIDIZED-BED COMBUSTION; HEAVY-METALS; TRACE-ELEMENTS; HUMAN HEALTH; URBAN SOILS; SOLID-WASTE; CHINA; DUST; SIZE; RESUSPENSION;
D O I
10.4209/aaqr.2017.02.0071
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study 15 fly ash samples were collected from 15 large-scale coal-fired power plants (CFPPs) in China. The samples were then re-suspended through PM2.5 and PM10 inlets and analyzed for the contents of 39 inorganic elements (IEs) using inductively coupled plasma-mass spectroscopy (ICP-MS) and inductively coupled plasma-optical emission spectrometry (ICP-OES). The results show that the particle size distributions for the 15 FAs samples exhibited bimodal patterns. The Sigma 39IEs (g g(-1)) for the PM2.5 (0.292-0.564) in all the 15 CFPPs were higher than that of PM10 (0.269-0.403). Except for Cu, all the other 38 IEs were more enriched in the PM2.5 with the PM2.5/PM10 ratios being 1.06-1.73. Considering 13 heavy metals, the same orders occurred between PM2.5 and PM10 with Al >> Cr > Zn > Mn > Cu > V > Pb > Sn > Co > As > Sb > Tl > Cd. More attention should be paid to the high contents of Cr in both PM2.5 (1310 mg g(-1)) and for PM10 (1240 mg g(-1)) from all 15 CFPPs. 23 IEs for PM10 and 26 IEs for PM2.5 had the geo-accumulation index (Igeo) values higher than 0, indicating different pollution levels for them. On the other hand, there was moderate to extreme levels of pollution for Cr, Zn, Cu, Pb, Sn, Sb, Tl, Cd and Al based on Igeo values. The element profiles for PM2.5 or PM10 from 15 CFPPs were similar based on low coefficients of divergence for PM2.5 (0.254 +/- 0.038) and PM10 (0.244 +/- 0.054) according to the comparison between any two CFPPs. Most elements with low relative enrichment factors (REF) as less than 0.70 or 0.70-1.30 indicated no or weak condensation occurred for them during coal combustion, while Cr, Cu, Zn, Sn, W and Pb had REF values higher than 1.30 indicated that significant condensation occurred for these elements.
引用
收藏
页码:1105 / 1116
页数:12
相关论文
共 50 条
[31]   The emissions and environmental impact of PM10 and trace elements from a modern coal-fired power plant equipped with ESP and wet FGD [J].
Meij, R ;
Winkel, HT .
FUEL PROCESSING TECHNOLOGY, 2004, 85 (6-7) :641-656
[32]   Characteristics, sources, and health risks of inorganic elements in PM2.5 and PM10 at Tianjin Binhai international airport* [J].
Zhang, Qijun ;
Yang, Lei ;
Peng, Jianfei ;
Wu, Lin ;
Mao, Hongjun .
ENVIRONMENTAL POLLUTION, 2023, 332
[33]   Chemical characterization of PM10 and PM2.5 mass concentrations emitted by heterogeneous traffic [J].
Srimuruganandam, B. ;
Nagendra, S. M. Shiva .
SCIENCE OF THE TOTAL ENVIRONMENT, 2011, 409 (17) :3144-3157
[34]   Influence of traffic on the PM10 and PM2.5 urban aerosol fractions in Madrid (Spain) [J].
Artíñano, B ;
Salvador, P ;
Alonso, DG ;
Querol, X ;
Alastuey, A .
SCIENCE OF THE TOTAL ENVIRONMENT, 2004, 334 :111-123
[35]   Emission Characteristics of PM10 and PM2.5 in Thermal Power Plants Using Different Fuel Types [J].
Park, Hyun-Soo ;
Lee, Duk-An ;
Yang, Jeong-Go ;
Jang, Seong-Guk ;
Kim, Hwan-Beom ;
Kim, Deug-Soo .
JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2018, 34 (04) :534-541
[36]   Field Measurements on the Emission and Removal of PM2.5 from Coal-Fired Power Stations: 4. PM Removal Performance of Wet Electrostatic Precipitators [J].
Xu, Yishu ;
Liu, Xiaowei ;
Cui, Jiang ;
Chen, Dong ;
Xu, Minghou ;
Pan, Siwei ;
Zhang, Kai ;
Gao, Xiangpeng .
ENERGY & FUELS, 2016, 30 (09) :7465-7473
[37]   Characterization of of PM10 and PM2.5 in Cheonan Area Using a Dust Monitor [J].
Lee, Hyunmi ;
Oh, Sewon .
JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2008, 24 (03) :367-375
[38]   Application of PMF and CMB receptor models for the evaluation of the contribution of a large coal-fired power plant to PM10 concentrations [J].
Contini, Daniele ;
Cesari, Daniela ;
Conte, Marianna ;
Donateo, Antonio .
SCIENCE OF THE TOTAL ENVIRONMENT, 2016, 560 :131-140
[39]   Characterization and Mutagenicity Assessment of PM2.5 and PM10 PAH at Agra, India [J].
Singla, Vyoma ;
Pachauri, Tripti ;
Satsangi, Aparna ;
Kumari, K. Maharaj ;
Lakhani, Anita .
POLYCYCLIC AROMATIC COMPOUNDS, 2012, 32 (02) :199-220
[40]   Characterization of PM2.5 Mass in Relation to PM1.0 and PM10 in Megacity Seoul [J].
Han, Jihyun ;
Lim, Seahee ;
Lee, Meehye ;
Lee, Young Jae ;
Lee, Gangwoong ;
Shim, Changsub ;
Chang, Lim-Seok .
ASIAN JOURNAL OF ATMOSPHERIC ENVIRONMENT, 2022, 16 (01)