What's the Control in Studies Measuring the Effect of Computer-Aided Detection (CAD) on Observer Performance?

被引:15
作者
Obuchowski, Nancy A. [1 ]
Meziane, Moulay [1 ]
Dachman, Abraham H. [3 ]
Lieber, Michael L.
Mazzone, Peter J. [2 ]
机构
[1] Cleveland Clin Fdn, Imaging Inst, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Resp Inst, Cleveland, OH 44195 USA
[3] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
CADe; ROC analysis; MRMC study; diagnostic accuracy; SCREENING MAMMOGRAPHY; IMAGING-SYSTEMS; COLONOGRAPHY; ACCURACY; NODULES;
D O I
10.1016/j.acra.2010.01.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: The goal of many multiple-observer computer-aided detection (CADe) studies is to estimate the change in observers' diagnostic performance with CADe from their unaided performance. A key issue in these studies is the method for estimating the observers' unaided performance. The crossover design is considered the most valid. The sequential design takes less time and is less expensive but may be biased. We conducted a study to investigate the differences between these two designs. Materials and Methods: Data from two large CADe studies using both types of unaided reads were analyzed. The first study involved three radiologists examining the chest x-rays of 200 patients for lung nodules. The second study involved 19 observers interpreting the computed tomography colonography images of 100 patients for polyps. Observers' sensitivity, specificity, and receiver operating characteristic areas were estimated while unaided in both designs and compared to their accuracy with CADe. Bias, inter-observer variability, and correlations between unaided and aided results were assessed. Results: Observers tend to perform better while unaided in the sequential design than while unaided in the crossover design, but the differences are small. The inter-observer variability is larger in the sequential design. The correlations between unaided and aided results are larger in the sequential design. 95% CIs for the change with CADe are narrower with the sequential design. Conclusion: The estimated effect of CADe on observer performance is similar regardless of the study design. Use of the sequential design may save investigators time and resources.
引用
收藏
页码:761 / 767
页数:7
相关论文
共 18 条
[11]   Computed tomographic colonography: Assessment of radiologist performance with and without computer-aided detection [J].
Halligan, Steve ;
Altman, Douglas G. ;
Mallett, Susan ;
Taylor, Stuart A. ;
Burling, David ;
Roddie, Mary ;
Honeyfield, Lesley ;
McQuillan, Justine ;
Amin, Hamdan ;
Dehmeshki, Jamshid .
GASTROENTEROLOGY, 2006, 131 (06) :1690-1699
[12]   HYPOTHESIS-TESTING OF DIAGNOSTIC-ACCURACY FOR MULTIPLE READERS AND MULTIPLE TESTS - AN ANOVA APPROACH WITH DEPENDENT OBSERVATIONS [J].
OBUCHOWSKI, NA ;
ROCKETTE, HE .
COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 1995, 24 (02) :285-308
[13]   Nonparametric analysis of clustered ROC curve data [J].
Obuchowski, NA .
BIOMETRICS, 1997, 53 (02) :567-578
[14]   Bias, underestimation of risk, and loss of statistical power in patient-level analyses of lesion detection [J].
Obuchowski, Nancy A. ;
Mazzone, Peter J. ;
Dachman, Abraham H. .
EUROPEAN RADIOLOGY, 2010, 20 (03) :584-594
[15]   Assessing mammographers' accuracy: A comparison of clinical and test performance [J].
Rutter, CM ;
Taplin, S .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2000, 53 (05) :443-450
[16]   Assessment of medical imaging systems and computer aids: A tutorial review [J].
Wagner, Robert F. ;
Metz, Charles E. ;
Campbell, Gregory .
ACADEMIC RADIOLOGY, 2007, 14 (06) :723-748
[17]   CT colonography reporting and data system: A consensus proposal [J].
Zalis, ME ;
Barish, MA ;
Choi, JR ;
Dachman, AH ;
Fenlon, HM ;
Ferrucci, JT ;
Glick, SN ;
Laghi, A ;
Macari, M ;
McFarland, EG ;
Morrin, MM ;
Pickhardt, PJ ;
Soto, J ;
Yee, J .
RADIOLOGY, 2005, 236 (01) :3-9
[18]  
DRAFT GUIDANCE IND F, P12