Assessment of CO2 and aerosol (PM2.5, PM10, UFP) concentrations during the reopening of schools in the COVID-19 pandemic: The case of a metropolitan area in Central-Southern Spain

被引:47
作者
Villanueva, Florentina [1 ,2 ]
Notario, Alberto [1 ,3 ]
Cabanas, Beatriz [1 ,3 ]
Martin, Pilar [1 ,3 ]
Salgado, Sagrario [1 ,3 ]
Gabriel, Marta Fonseca [4 ]
机构
[1] Univ Castilla La Mancha, Inst Invest Combust & Contaminac Atmosfer, Camino Moledores S-N, Ciudad Real 13071, Spain
[2] Parque Cient & Tecnol Castilla La Mancha, Paseo Innovac 1, Albacete 02006, Spain
[3] Univ Castilla La Mancha, Fac Ciencias & Tecnol Quim, Dept Quim Fis, Ave Camilo Jose Cela S-N, Ciudad Real 13071, Spain
[4] Inst Sci & Innovat Mech & Ind Engn, INEGI, Campus FEUP,Rua Dr Roberto Frias 400, P-4200465 Porto, Portugal
关键词
COVID-19; pandemic; Particulate matter; SARS-CoV-2 transmission risk mitigation; School environment; Ventilation conditions; AIRBORNE TRANSMISSION; ULTRAFINE PARTICLES; AIR-POLLUTANTS; INDOOR; VENTILATION; POLLUTION; EXPOSURE; QUALITY;
D O I
10.1016/j.envres.2021.111092
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Public health authorities have been paramount in guaranteeing that adequate fresh air ventilation is promoted in classrooms to avoid SARS-CoV-2 transmission in educational environments. In this work it was aimed to assess ventilation conditions (carbon dioxide, CO2) and suspended particulate matter (PM2.5, PM10 and UFP) levels in 19 classrooms - including preschool, primary and secondary education - located in the metropolitan area of Ciudad Real, Central-Southern Spain, during the school's reopening (from September 30th until October 27th, 2020) after about 7 months of lockdown due to COVID-19 pandemic. The classrooms that presented the worst indoor environmental conditions, according to the highest peak of concentration obtained, were particularly explored to identify the possible influencing factors and respective opportunities for improvement. Briefly, findings suggested that although ventilation promoted through opening windows and doors according to official recommendations is guaranteeing adequate ventilation conditions in most of the studied classrooms, thus minimizing the risk of SARS-CoV-2 airborne transmission, a total of 5 (26%) surveyed classrooms were found to exceed the recommended CO2 concentration limit value (700 ppm). In general, preschool rooms were the educational environments that registered better ventilation conditions, while secondary classrooms exhibited the highest peak and average CO2 concentrations. In turn, for PM2.5, PM10 and UFP, the concentrations assessed in preschools were, on average about 2-fold greater than the levels obtained in both primary and secondary classrooms. In fact, the indoor PM2.5 and PM10 concentrations substantially exceeded the recommended limits of 8hr-exposure, established by WHO, in 63% and 32% of the surveyed classrooms, respectively. Overall, it is expected that the findings presented in this study will assist the establishment of evidence-based measures (namely based on ensuring proper ventilation rates and air filtration) to mitigate preventable environmental harm in public school buildings, mainly at local and national levels.
引用
收藏
页数:10
相关论文
共 47 条
  • [1] Recognizing and controlling airborne transmission of SARS-CoV-2 in indoor environments
    Allen, Joseph G.
    Marr, Linsey C.
    [J]. INDOOR AIR, 2020, 30 (04) : 557 - 558
  • [2] Poor air quality in classrooms related to asthma and rhinitis in primary schoolchildren of the French 6 Cities Study
    Annesi-Maesano, Isabella
    Hulin, Marion
    Lavaud, Francois
    Raherison, Chantal
    Kopferschmitt, Christine
    de Blay, Frederic
    Charpin, Denis Andre
    Denis, Caillaud
    [J]. THORAX, 2012, 67 (08) : 682 - 688
  • [3] [Anonymous], 2020, INDOOR AIR, DOI DOI 10.1111/ina.12766
  • [4] [Anonymous], 2020, LANCET INFECT DIS, DOI DOI 10.1016/S1473-3099(20)30243-7
  • [5] Fine and ultrafine particles in small cities. A case study in the south of Europe
    Aranda, A.
    Diaz-de-Mera, Y.
    Notario, A.
    Rodriguez, D.
    Rodriguez, A.
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2015, 22 (23) : 18477 - 18486
  • [6] Axfors C., 2020, ENVIRON RES, V188, P109890, DOI [10.1016/j.envres.2020.109890, DOI 10.1016/j.envres.2020.109890]
  • [7] Indoor air pollution, physical and comfort parameters related to schoolchildren's health: Data from the European SINPHONIE study
    Baloch, Ramen Munir
    Maesano, Cara Nichole
    Christoffersen, Jens
    Banerjee, Soutrik
    Gabriel, Marta
    Csobod, Eva
    Fernandes, Eduardo de Oliveira
    Annesi-Maesano, Isabella
    Csobod, Eva
    Szuppinger, Peter
    Prokai, Reka
    Farkas, Petur
    Fuzi, Cecilia
    Cani, Eduart
    Draganic, Jasna
    Mogyorosy, Eszter Reka
    Korac, Zorica
    Ventura, Gabriela
    Madureira, Joana
    Paciencia, Ines
    Martins, Anabela
    Pereira, Ricardo
    Ramos, Elisabete
    Rudnai, Peter
    Paldy, Anna
    Dura, Gyula
    Beregszaszi, Timea
    Vaskovi, Eva
    Magyar, Donat
    Pandics, Tamas
    Remeny-Nagy, Zsuzsanna
    Szentmihalyi, Renata
    Udvardy, Orsolya
    Varro, Mihaly J.
    Kephalopoulos, Stylianos
    Kotzias, Dimitrios
    Barrero-Moreno, Josefa
    Mehmeti, Rahmije
    Vilic, Aida
    Maestro, Daniel
    Moshammer, Hanns
    Strasser, Gabriela
    Brigitte, Piegler
    Hohenblum, Philipp
    Goelen, Eddy
    Stranger, Marianne
    Spruy, Maarten
    Sidjimov, Momchil
    Hadjipanayis, Adamos
    Katsonouri-Sazeides, Andromachi
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 739
  • [8] Bi Q, 2020, EPIDEMIOLOGY TRANSMI, DOI 10.1101/2020.03.03.20028423
  • [9] CO2 Concentration and Occupants' Symptoms in Naturally Ventilated Schools in Mediterranean Climate
    Fernandez-Aguera, Jesica
    Angel Campano, Miguel
    Dominguez-Amarillo, Samuel
    Acosta, Ignacio
    Sendra, Juan Jose
    [J]. BUILDINGS, 2019, 9 (09)
  • [10] The ventilation problem in schools: literature review
    Fisk, W. J.
    [J]. INDOOR AIR, 2017, 27 (06) : 1039 - 1051