Head-to-Head Comparison of 11C-PBR28 and 18F-GE180 for Quantification of the Translocator Protein in the Human Brain

被引:50
作者
Zanotti-Fregonara, Paolo [1 ,2 ]
Pascual, Belen [1 ,2 ]
Rizzo, Gaia [3 ,4 ]
Yu, Meixiang [1 ,2 ]
Pal, Neha [1 ,2 ]
Beers, David [1 ,2 ]
Carter, Randall [5 ]
Appel, Stanley H. [1 ,2 ]
Atassi, Nazem [6 ]
Masdeu, Joseph C. [1 ,2 ]
机构
[1] Houston Methodist Res Inst, Nantz Natl Alzheimer Ctr, Houston, TX USA
[2] Weill Cornell Med, Houston, TX USA
[3] Invicro, London, England
[4] Imperial Coll London, Dept Med, Div Brain Sci, London, England
[5] GE Global Res, Schenectady, NY USA
[6] Massachusetts Gen Hosp, Neurol Clin Res Inst, Boston, MA 02114 USA
关键词
C-11-PBR28; F-18-GE180; TSPO; POSITRON-EMISSION-TOMOGRAPHY; VIVO RADIOLIGAND BINDING; ASSESS RADIATION SAFETY; IN-VIVO; 18; KDA; PET RADIOLIGAND; TSPO PET; SUGGESTED PATHWAY; KINETIC-ANALYSIS; MODEL;
D O I
10.2967/jnumed.117.203109
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
F-18-GE180 is a third-generation PET tracer for quantifying the translocator protein (TSPO), a biomarker for inflammation. The aim of this study was to perform a head-to-head comparison of F-18-GE180 and the well-established TSPO tracer C-11-PBR28 by scanning with both tracers during the same day in the same subjects. Methods: Five subjects underwent a 90-min PET scan with C-11-PBR28 in the morning and F-18-GE180 in the afternoon. A metabolite-corrected arterial input function was obtained in each subject for both tracers, and the brain uptake was quantified with a 2-tissue-compartment model. Results: The rate of metabolism of F-18-GE180 in arterial blood was slower than that of C-11-PBR28 (the percentages of non-metabolized parent in plasma at 90 min were 74.9%+/- 4.15%[mean +/- SD] and 11.2% +/- 1.90%, respectively). The plasma free fractions were similar for both tracers: 3.5% +/- 1.1% for F-18-GE180 and 4.1% +/- 1.1% for C-11-PBR28. The average total volume of distribution (VT) of F-18-GE180 was about 20 times smaller than that of C-11-PBR28 (0.15 +/- 0.03 mL/cm(3) for F-18-GE180 and 3.27 +/- 0.66 mL/cm(3) for C-11-PBR28). F-18-GE180 was characterized by poor transfer from the vascular compartment to the brain (its plasma-to-tissue rate constant [K1] was about 10 times smaller than that of C-11-PBR28). Moreover, kinetic modeling was more difficult with F-18-GE180, as its VT values were identified with a lower precision than those of C-11-PBR28 and outlying values were more frequent. Conclusion: The VT of F-18-GE180 was about 20 times smaller than that of C-11-PBR28 because of low penetration into the brain from the vascular compartment. In addition, kinetic modeling of F-18-GE180 was more challenging than that of C-11-PBR28. Therefore, compared with C-11-PBR28, F-18-GE180 had unfavorable characteristics for TSPO imaging of the brain.
引用
收藏
页码:1260 / 1266
页数:7
相关论文
共 50 条
[11]   Comparison of 18F- and 11C-labeled aryloxyanilide analogs to measure translocator protein in human brain using positron emission tomography [J].
Dickstein, Leah P. ;
Zoghbi, Sami S. ;
Fujimura, Yota ;
Imaizumi, Masao ;
Zhang, Yi ;
Pike, Victor W. ;
Innis, Robert B. ;
Fujita, Masahiro .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (02) :352-357
[12]   Flutriciclamide (18F-GE180) PET: First-in-Human PET Study of Novel Third-Generation In Vivo Marker of Human Translocator Protein [J].
Fan, Zhen ;
Calsolaro, Valeria ;
Atkinson, Rebecca A. ;
Femminella, Grazia D. ;
Waldman, Adam ;
Buckley, Christopher ;
Trigg, William ;
Brooks, David J. ;
Hinz, Rainer ;
Edison, Paul .
JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (11) :1753-1759
[13]   Kinetic analysis of the translocator protein positron emission tomography ligand [18F]GE-180 in the human brain [J].
Feeney, Claire ;
Scott, Gregory ;
Raffel, Joel ;
Roberts, S. ;
Coello, Christopher ;
Jolly, Amy ;
Searle, Graham ;
Goldstone, A. P. ;
Brooks, David J. ;
Nicholas, Richard S. ;
Trigg, William ;
Gunn, Roger N. ;
Sharp, David J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (12) :2201-2210
[14]   EVALUATION OF ULTRAFILTRATION FOR THE FREE-FRACTION DETERMINATION OF SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY (SPECT) RADIOTRACERS - BETA-CIT, IBF, AND IOMAZENIL [J].
GANDELMAN, MS ;
BALDWIN, RM ;
ZOGHBI, SS ;
ZEAPONCE, Y ;
INNIS, RB .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1994, 83 (07) :1014-1019
[15]   Neuroinflammation in Temporal Lobe Epilepsy Measured Using Positron Emission Tomographic Imaging of Translocator Protein [J].
Gershen, Leah D. ;
Zanotti-Fregonara, Paolo ;
Dustin, Irene H. ;
Liow, Jeih-San ;
Hirvonen, Jussi ;
Kreisl, William C. ;
Jenko, Kimberly J. ;
Inati, Sara K. ;
Fujita, Masahiro ;
Morse, Cheryl L. ;
Brouwer, Chad ;
Hong, Jinsoo S. ;
Pike, Victor W. ;
Zoghbi, Sami S. ;
Innis, Robert B. ;
Theodore, William H. .
JAMA NEUROLOGY, 2015, 72 (08) :882-888
[16]   A Randomized Trial of Bevacizumab for Newly Diagnosed Glioblastoma [J].
Gilbert, Mark R. ;
Dignam, James J. ;
Armstrong, Terri S. ;
Wefel, Jeffrey S. ;
Blumenthal, Deborah T. ;
Vogelbaum, Michael A. ;
Colman, Howard ;
Chakravarti, Arnab ;
Pugh, Stephanie ;
Won, Minhee ;
Jeraj, Robert ;
Brown, Paul D. ;
Jaeckle, Kurt A. ;
Schiff, David ;
Stieber, Volker W. ;
Brachman, David G. ;
Werner-Wasik, Maria ;
Tremont-Lukats, Ivo W. ;
Sulman, Erik P. ;
Aldape, Kenneth D. ;
Curran, Walter J., Jr. ;
Mehta, Minesh P. .
NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (08) :699-708
[17]   L-(methyl-11C) methionine positron emission tomography for target delineation in resected high-grade gliomas before radiotherapy [J].
Grosu, AL ;
Weber, WA ;
Riedel, E ;
Jeremic, B ;
Nieder, C ;
Franz, M ;
Gumprecht, H ;
Jaeger, R ;
Schwaiger, M ;
Molls, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (01) :64-74
[18]   Translocator protein and new targets for neuroinflammation [J].
Herrera-Rivero M. ;
Heneka M.T. ;
Papadopoulos V. .
Clinical and Translational Imaging, 2015, 3 (6) :391-402
[19]   11C-ER176, a Radioligand for 18-kDa Translocator Protein, Has Adequate Sensitivity to Robustly Image All Three Affinity Genotypes in Human Brain [J].
Ikawa, Masamichi ;
Lohith, Talakad G. ;
Shrestha, Stal ;
Telu, Sanjay ;
Zoghbi, Sami S. ;
Castellano, Sabrina ;
Taliani, Sabrina ;
Da Settimo, Federico ;
Fujita, Masahiro ;
Pike, Victor W. ;
Innis, Robert B. .
JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (02) :320-325
[20]  
Jacobs AH, 2005, J NUCL MED, V46, P1948