The Application Study of Specific Ankle-Foot Orthoses for Stroke Patients by 3D Printing Somos NeXt

被引:3
|
作者
Liu, Zhen [1 ,2 ]
Zhang, Pande [2 ]
Yan, Ming [3 ]
Ren, Xin [4 ]
Xie, Yimin [5 ]
Huang, Guozhi [6 ]
机构
[1] Southern Med Univ, Guangzhou 528000, Guangdong, Peoples R China
[2] First Peoples Hosp Foshan, Dept Rehabil Med, Foshan 528000, Guangdong, Peoples R China
[3] First Peoples Hosp Foshan, Dept Gynecol, Foshan 528000, Guangdong, Peoples R China
[4] Nanjing Tech Univ, Coll Civil Engn, Nanjing 211816, Jiangsu, Peoples R China
[5] RM1T Univ, Ctr Innovat Struct & Mat, Sch Engn, Melbourne, Vic 3001, Australia
[6] Southern Med Univ, Zhujiang Hosp, Dept Rehabil Med, Guangzhou 510280, Guangdong, Peoples R China
关键词
Ankle-Foot Orthoses; Stroke Patients; Somos NeXt; GAIT; DROP; STIMULATION;
D O I
10.1166/jbt.2019.2052
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Objective: To investigate the effects of specific ankle-foot orthoses (AFOs) fabricated by 3D printing Somos NeXt on patients with stroke. Method : The ankle and foot were scanned by Artec 3D scanner. The model was performed with finite element analysis (FEA) using the software Abaqus to optimize the structure. Based on the structural optimization, AFOs were fabricated by 3D printing technique of Somos NeXt. Gait parameters were measured using the Gait Watch system. Seven sensors were bound to the sacrum, anterior side in the middle segment of the bilateral femoral femur, the median side at the proximal end of the bilateral tibia, and dorsal part of the bilateral foot. Results: The AFOs fabricated by 3D printing Somos NeXt significantly improved the temporal-spatial parameters including velocity (20.75 vs. 17.38 cm/s) and stride length (47.88 vs. 43.63 cm), as well as increased cadence (52.5 vs. 48.75 times/min), while slightly decreased gait cycle (2.57 vs. 2.80 cm) and double limb support phase (34.00 vs. 37.13%). The AFOs also improved symmetry parameters such as the step length difference (9.75 vs. 15.25 cm), step length ratio (1.87 vs. 3.98), and swing phase ratio (0.99 vs. 0.75). Conclusion: The AFOs fabricated by 3D printing Somos NeXt have a significant effect on the improvement of velocity and stride length in patients with stroke.
引用
收藏
页码:745 / 750
页数:6
相关论文
共 30 条
  • [1] Tuning the mechanical responses of 3D-printed ankle-foot orthoses: A numerical study
    Peng, Chenxi
    Tran, Phuong
    Lalor, Simon
    Tirosh, Doren
    Rutz, Erich
    INTERNATIONAL JOURNAL OF BIOPRINTING, 2024, 10 (03)
  • [2] Energy expenditure and walking ability in stroke patients: Their improvement by ankle-foot orthoses
    Maeda, Noriaki
    Kato, Junichi
    Azuma, Yuji
    Okuyama, Sou
    Yonei, Satoshi
    Murakami, Masahito
    Shimada, Tomoaki
    ISOKINETICS AND EXERCISE SCIENCE, 2009, 17 (02) : 57 - 62
  • [3] Feasibility of designing, manufacturing and delivering 3D printed ankle-foot orthoses: a systematic review
    Elizabeth Wojciechowski
    Angela Y. Chang
    Daniel Balassone
    Jacqueline Ford
    Tegan L. Cheng
    David Little
    Manoj P. Menezes
    Sean Hogan
    Joshua Burns
    Journal of Foot and Ankle Research, 12
  • [4] Feasibility of designing, manufacturing and delivering 3D printed ankle-foot orthoses: a systematic review
    Wojciechowski, Elizabeth
    Chang, Angela Y.
    Balassone, Daniel
    Ford, Jacqueline
    Cheng, Tegan L.
    Little, David
    Menezes, Manoj P.
    Hogan, Sean
    Burns, Joshua
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2019, 12 (1)
  • [5] Effect of different designs of ankle-foot orthoses on gait in patients with stroke: A systematic review
    Daryabor, Aliyeh
    Arazpour, Mokhtar
    Aminian, Gholamreza
    GAIT & POSTURE, 2018, 62 : 268 - 279
  • [6] Numerical study of patient-specific ankle-foot orthoses for drop foot patients using shape memory alloy
    Sadeghian, Farshid
    Zakerzadeh, Mohammad Reza
    Karimpour, Morad
    Baghani, Mostafa
    MEDICAL ENGINEERING & PHYSICS, 2019, 69 : 123 - 133
  • [7] Mechanical Problem in 3D Printed Ankle-Foot Orthoses with Function of Energy Storage<bold> </bold>
    Yeh, Chien-Hsien
    Tsai, Yi-Chun
    Su, Fong-Chin
    Kuo, Li-Chieh
    Chang, Kai
    Chuang, Ping-Han
    ICNPAA 2018 WORLD CONGRESS: 12TH INTERNATIONAL CONFERENCE ON MATHEMATICAL PROBLEMS IN ENGINEERING, AEROSPACE AND SCIENCES, 2018, 2046
  • [8] Effects of elastic neutral ankle-foot orthoses on 3 dimensional parameters during gait training in patients with stroke: A pilot study
    Hwang, Young-In
    Park, Du-Jin
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2021, 27 : 300 - 306
  • [9] Effect of Ankle-Foot Orthoses on the Sagittal Plane Displacement of the Center of Mass in Patients With Stroke Hemiplegia: A Pilot Study
    Kobayashi, Toshiki
    Leung, Aaron K. L.
    Akazawa, Yasushi
    Hutchins, Stephen W.
    TOPICS IN STROKE REHABILITATION, 2012, 19 (04) : 338 - 344
  • [10] Kinematic Features of Rear-Foot Motion Using Anterior and Posterior Ankle-Foot Orthoses in Stroke Patients With Hemiplegic Gait
    Chen, Chih-Chi
    Hong, Wei-Hsien
    Wang, Chin-Man
    Chen, Chih-Kuang
    Wu, Katie Pei-Hsuan
    Kang, Chao-Fu
    Tang, Simon F.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2010, 91 (12): : 1862 - 1868