Effect of titanium nitride/titanium coatings on the stress corrosion of nickel-titanium orthodontic archwires in artificial saliva

被引:14
作者
Liu, Jia-Kuang [1 ,2 ]
Liu, I-Hua [3 ]
Liu, Cheng [4 ,5 ,6 ]
Chang, Chen-Jung [1 ,2 ]
Kung, Kuan-Chen [1 ]
Liu, Yen-Ting [7 ]
Lee, Tzer-Min [1 ]
Jou, Jin-Long [8 ]
机构
[1] Natl Cheng Kung Univ, Inst Oral Med, Tainan 70101, Taiwan
[2] Natl Cheng Kung Univ Hosp, Dept Stomatol, Div Orthodont, Tainan 70428, Taiwan
[3] Chi Mei Med Ctr, Dept Dent, Div Orthodont, Tainan, Taiwan
[4] Chi Mei Med Ctr, Dept Surg, Div Plast Surg, Tainan, Taiwan
[5] Chia Nan Univ Pharm & Sci, Dept Cosmet Sci, Tainan, Taiwan
[6] Chia Nan Univ Pharm & Sci, Inst Cosmet Sci, Tainan, Taiwan
[7] Natl Cheng Kung Univ, Dept Mat Sci & Engn, Tainan 70101, Taiwan
[8] United Orthoped Corp, Kaohsiung, Taiwan
关键词
TiN/Ti coating; Orthodontic Nickel titanium (NiTi); Stress corrosion; Bending stress; Localized corrosion; SURFACE CHARACTERIZATION; TI INTERLAYER; NITI; BEHAVIOR; RESISTANCE; APPLIANCES; IMPLANTS; BRACKET; ALLOY; FORCE;
D O I
10.1016/j.apsusc.2014.08.132
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The purpose of this investigation was to develop titanium nitride (TiN)/titanium (Ti) coating on orthodontic nickel-titanium (NiTi) wires and to study the stress corrosion of specimens in vitro, simulating the intra-oral environment in as realistic a manner as possible. TiN/Ti coatings were formed on orthodontic NiTi wires by physical vapor deposition (PVD). The characteristics of untreated and TiN/Ti-coated NiTi wires were evaluated by measurement of corrosion potential (E-corr), corrosion current densities breakdown potential (E-b), and surface morphology in artificial saliva with different pH and three-point bending conditions. From the potentiodynamic polarization and SEM results, the untreated NiTi wires showed localized corrosion compared with the uniform corrosion observed in the TiN/Ti-coated specimen under both unstressed and stressed conditions. The bending stress influenced the corrosion current density and breakdown potential of untreated specimens at both pH 2 and pH 5.3. Although the bending stress influenced the corrosion current of the TiN/Ti-coated specimens, stable and passive corrosion behavior of the stressed specimen was observed even at 2.0 V (Ag/AgCl). It should be noted that the surface properties of the NiTi alloy could determine clinical performance. For orthodontic application, the mechanical damage destroys the protective oxide film of NiTi; however, the self-repairing capacity of the passive film of NiTi alloys is inferior to Ti in chloride-containing solutions. In this study, the TiN coating was found able to provide protection against mechanical damage, while the Ti interlayer improved the corrosion properties in an aggressive environment. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:974 / 981
页数:8
相关论文
共 50 条
[21]   Evaluation of nanomechanical properties, surface roughness, and color stability of esthetic nickel-titanium orthodontic archwires [J].
Alsanea, Jamal A. ;
Al Shehri, Hassan .
JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2019, 9 (01) :33-39
[22]   Transition temperature range of thermally activated nickel-titanium archwires [J].
Spini, Tatiana Sobottka ;
Valarelli, Fabricio Pinelli ;
Cancado, Rodrigo Hermont ;
Salvatore de Freitas, Karina Maria ;
Villarinho, Denis Jardim .
JOURNAL OF APPLIED ORAL SCIENCE, 2014, 22 (02) :109-117
[23]   MECHANICAL PERFORMANCE OF DIFFERENT NICKEL-TITANIUM ARCHWIRES USED IN DENTISTRY [J].
Fernandes, Daniel J. ;
Elias, Carlos N. ;
Peres, Rafael V. .
TMS 2014 SUPPLEMENTAL PROCEEDINGS, 2014, :213-215
[24]   A comparative study of the cytotoxicity and corrosion resistance of nickel-titanium and titanium-niobium shape memory alloys [J].
McMahon, Rebecca E. ;
Ma, Ji ;
Verkhoturov, Stanislav V. ;
Munoz-Pinto, Dany ;
Karaman, Ibrahim ;
Rubitschek, Felix ;
Maier, Hans J. ;
Hahn, Mariah S. .
ACTA BIOMATERIALIA, 2012, 8 (07) :2863-2870
[25]   Influence of intraoral application of antiseptics and fluorides during orthodontic treatment on corrosion and mechanical characteristics of nickel-titanium alloy in orthodontic appliances [J].
Belasic, Tihana Zibar ;
Pejova, Biljana ;
Curkovic, Helena Otmacic ;
Kamenar, Ervin ;
Cetenovic, Bojana ;
Spalj, Stjepan .
ANGLE ORTHODONTIST, 2021, 91 (04) :528-537
[26]   Effects of intraoral aging on surface properties of coated nickel-titanium archwires [J].
Rongo, Roberto ;
Ametrano, Gianluca ;
Gloria, Antonio ;
Spagnuolo, Gianrico ;
Galeotti, Angela ;
Paduano, Sergio ;
Valletta, Rosa ;
D'Anto, Vincenzo .
ANGLE ORTHODONTIST, 2014, 84 (04) :665-672
[27]   The effect of different titanium nitride coatings on the adhesion of Candida albicans to titanium [J].
Wang, Jing ;
An, Yanxin ;
Liang, Haifeng ;
Tong, Yu ;
Guo, Tianwen ;
Ma, Chufan .
ARCHIVES OF ORAL BIOLOGY, 2013, 58 (10) :1293-1301
[28]   Load Deflection Characteristics of Orthodontic Gummetal® Wires in Comparison with Nickel-Titanium Wires: An In Vitro Study [J].
Sabbagh, Hisham ;
Janjic Rankovic, Mila ;
Martin, Daniel ;
Mertmann, Matthias ;
Hoetzel, Linus ;
Wichelhaus, Andrea ;
Sfondrini, Maria Francesca .
MATERIALS, 2024, 17 (02)
[29]   A comparative assessment of clinical efficiency between premium heat-activated copper nickel-titanium and superelastic nickel-titanium archwires during initial orthodontic alignment in adolescents: a randomized clinical trial [J].
Atik, Ezgi ;
Gorucu-Coskuner, Hande ;
Akarsu-Guven, Bengisu ;
Taner, Tulin .
PROGRESS IN ORTHODONTICS, 2019, 20 (01)
[30]   Corrosion of orthodontic archwires in artificial saliva in the presence of Lactobacillus reuteri [J].
Trolic, Ines Musa ;
Serdarevic, Nikolina Leona ;
Todoric, Zrinka ;
Budimir, Ana ;
Spalj, Stjepan ;
Curkovic, Helena Otmacic .
SURFACE & COATINGS TECHNOLOGY, 2019, 370 :44-52