Modeling and analysis of static and dynamic characteristics for buck-type three-phase PWM rectifier by circuit DQ transformation

被引:40
作者
Han, SB
Choi, NS
Rim, CT
Cho, GH
机构
[1] Korea Inst Energy Res, Elect Energy Div, Taejon 305343, South Korea
[2] Natl Fisheries Univ, Dept Elect Engn, Yosu 550749, Chonam, South Korea
[3] Korea Adv Inst Sci & Technol, Dept Elect Engn, Taejon 305701, South Korea
关键词
circuit DQ transformation; current-source rectifier; PWM rectifier;
D O I
10.1109/63.662849
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The static and dynamic characteristics of buck-type three-phase pulse-width-modulation (PWM) rectifier are fully analyzed based on the dc and ac circuit models developed by the circuit DQ transformation. Various static converter characteristics such as gain, real and reactive power, power factor, and unity power factor conditions are completely analyzed. Transition characteristics are also analyzed by both exact small-signal model with full set of equations and simplified output model in explicit form. The usefulness of the models is verified through computer simulations and experiments with good agreements.
引用
收藏
页码:323 / 336
页数:14
相关论文
共 9 条
  • [1] A NEW CONTROL ALGORITHM FOR 3-PHASE PWM BUCK RECTIFIER WITH INPUT DISPLACEMENT FACTOR COMPENSATION
    HITI, S
    VLATKOVIC, V
    BOROJEVIC, D
    LEE, FCY
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 1994, 9 (02) : 173 - 180
  • [2] ANALYSES OF STATIC AND DYNAMIC CHARACTERISTICS OF PRACTICAL STEP-UP 9-SWITCH MATRIX CONVERTER
    KWON, WH
    CHO, GH
    [J]. IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1993, 140 (02): : 139 - 146
  • [3] OJO O, 1993, IAS 93, PTS 1-3, P917, DOI 10.1109/IAS.1993.299008
  • [4] TRANSFORMERS AS EQUIVALENT-CIRCUITS FOR SWITCHES - GENERAL PROOFS AND D-Q TRANSFORMATION-BASED ANALYSES
    RIM, CT
    HU, DY
    CHO, GH
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1990, 26 (04) : 777 - 785
  • [5] A COMPLETE DC AND AC ANALYSIS OF 3-PHASE CONTROLLED-CURRENT PWM RECTIFIER USING CIRCUIT D-Q TRANSFORMATION
    RIM, CT
    CHOI, NS
    CHO, GC
    CHO, GH
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 1994, 9 (04) : 390 - 396
  • [6] WANG X, 1992, IEEE POWER ELECTRON, P1376, DOI 10.1109/PESC.1992.254752
  • [7] A PERFORMANCE COMPARISON OF PWM RECTIFIERS AND SYNCHRONOUS LINK CONVERTERS
    ZARGARI, NR
    JOOS, G
    ZIOGAS, PD
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1994, 41 (05) : 560 - 562
  • [8] ZARGARI NR, 1994, IEEE POWER ELECTRON, P363, DOI 10.1109/PESC.1994.349708
  • [9] PWM CONTROL TECHNIQUES FOR RECTIFIER FILTER MINIMIZATION
    ZIOGAS, PD
    KANG, YG
    STEFANOVIC, VR
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1985, 21 (05) : 1206 - 1214