Limited incremental diagnostic values of attenuation-noncorrected gating and ungated attenuation correction to rest/stress myocardial perfusion SPECT in patients with an intermediate likelihood of coronary artery disease

被引:0
|
作者
Lee, DS
So, Y
Cheon, GJ
Kim, KM
Lee, MM
Chung, JK
Lee, MC
机构
[1] Seoul Natl Univ, Coll Med, Dept Nucl Med, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Internal Med, Seoul 110744, South Korea
[3] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul 110744, South Korea
关键词
CAD; gated myocardial SPECT; attenuation-corrected SPECT; ROC analysis; Tc-99m-MIBI;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Either gated myocardial perfusion SPECT or attenuation-corrected SPECT can be used to improve specificity in the diagnosis of coronary artery disease (CAD). We investigated whether attenuation-noncorrected gating and ungated attenuation correction could improve the diagnostic performance of rest/stress perfusion SPECT in patients having an intermediate pretest likelihood of CAD. Methods: Sixty-eight patients (29 men, 39 women; mean age, 59 +/- 12 y) with coronary artery stenosis greater than or equal to 70% (1 vessel, n = 13; 2 vessels, n = 18; 3 vessels, n = 8; normal, n = 29) underwent rest attenuation-corrected Tl-201 SPECT and dipyridamole stress gated attenuation-corrected Tc-99m-methoxyisobutyl isonitrile SPECT with an ADAC vertex camera. Three physicians graded the post-test likelihood of CAD for each arterial territory using a 5-point scale (1, normal; 2, possibly normal; 3, equivocal; 4, possibly abnormal; 5, abnormal). The sensitivity, specificity, and areas under receiver-operating-characteristic curves were compared for each operator by 3 methods: attenuation-noncorrected rest/stress SPECT, gated poststress SPECT plus attenuation-noncorrected rest/stress SPECT, and attenuation-corrected rest/stress SPECT plus gated poststress SPECT plus attenuation-noncorrected rest/stress SPECT Results: When higher than grade 3 was used as the criterion for CAD, no differences in sensitivity and specificity were found among the 3 methods for each operator, Areas under receiver-operating-characteristic curves for the diagnosis of CAD and stenosis revealed no differences for each modality (P > 0.05 for each comparison). Conclusion: In patients with an intermediate risk of CAD, viewing attenuation-noncorrected gated poststress SPECT and ungated attenuation-corrected rest/stress SPECT images did not improve the diagnostic performance for CAD and stenosis.
引用
收藏
页码:852 / 859
页数:8
相关论文
共 50 条
  • [1] Additive diagnostic values of eating and attenuation-correction to usual rest/stress perfusion SPECT in coronary artery disease?
    Lee, DS
    So, Y
    Kim, KM
    Chun, KJ
    Chung, JK
    Lee, MC
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 176A - 176A
  • [2] Attenuation correction and gating synergistically improve the diagnostic accuracy of myocardial perfusion SPECT
    Links, JM
    DePuey, EG
    Taillefer, R
    Becker, LC
    JOURNAL OF NUCLEAR CARDIOLOGY, 2002, 9 (02) : 183 - 187
  • [3] Attenuation correction and gating synergistically improve the diagnostic accuracy of myocardial perfusion SPECT
    Jonathan M. Links
    E. Gordon DePuey
    Raymond Taillefer
    Lewis C. Becker
    Journal of Nuclear Cardiology, 2002, 9 : 183 - 187
  • [4] Attenuation correction myocardial perfusion SPECT in the assessment of ischemia in patients with high prevalence of coronary artery disease
    Pilkington Woll, J. P.
    Poblete Garcia, V. M.
    Cordero Garcia, J. M.
    Garcia Vicente, A. M.
    Leon Martin, A.
    Sanchez Perez, I.
    Talavera Rubio, M. P.
    Lozano Ruiz-Poveda, F.
    Palomar Munoz, A. M.
    Bellon Guardia, M. E.
    Gonzalez Garcia, B.
    Cepedello Boiso, I.
    Fernandez Vallejo, V.
    Soriano Castrejon, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S321 - S321
  • [5] Diagnostic impact of CT attenuation correction on CZT myocardial perfusion SPECT in patients with coronary artery disease compared to cardiac SPECT/CT hybrid imaging
    Fukushima, Y.
    Kumita, S.
    Hashimoto, H.
    Sugihara, Y.
    Iwata, K.
    Hamana, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S558 - S558
  • [6] Attenuation corrected myocardial perfusion SPECT provides powerful risk stratification in patients with coronary artery disease
    Ernest V. Garcia
    Fabio P. Esteves
    Journal of Nuclear Cardiology, 2009, 16 : 490 - 492
  • [7] Attenuation corrected myocardial perfusion SPECT provides powerful risk stratification in patients with coronary artery disease
    Garcia, Ernest V.
    Esteves, Fabio P.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (04) : 490 - 492
  • [8] Attenuation correction of both stress and rest myocardial perfusion SPECT scans using a single transmission scan
    Case, JA
    Cullom, JS
    Bateman, TM
    Galt, JR
    Garcia, EV
    Moutray, KL
    CIRCULATION, 2001, 104 (17) : 612 - +
  • [9] Outcomes Analysis of Stress Only Gated Myocardial Perfusion Imaging With Attenuation Correction in Patients With Suspected Coronary Artery Disease
    Yekta, Arshad
    Ruffin, Richard
    Ahlberg, Alan
    Katten, Deborah
    Heller, Gary
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A296 - A296
  • [10] End-diastolic vs ungated attenuation corrected myocardial perfusion SPECT for the detection of coronary heart disease.
    Ficaro, EP
    Duvernoy, CS
    Fessler, JA
    Corbett, JR
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 74P - 74P