Need for Additional Glaucoma Surgery and Complications Following Glaucoma Drainage Device Surgery

被引:6
作者
Kung, Felix F. [1 ]
Knier, Catherine G. [1 ,2 ]
Garmany, Armin [1 ,2 ]
Mejia, Camilo A. [1 ]
Sargent, Jason M. [1 ]
Dogahe, Sepideh Jamali [3 ]
Sabbagh, Nouran [3 ]
Hodge, David O. [4 ]
Khanna, Cheryl L. [3 ]
机构
[1] Mayo Clin, Alix Sch Med, Rochester, MN 55905 USA
[2] Mayo Clin, Med Scientist Training Program, Grad Sch Biomed Sci, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Ophthalmol, 200 First St SW, Rochester, MN 55905 USA
[4] Mayo Clin, Dept Hlth Sci Res, Jacksonville, FL 32224 USA
关键词
glaucoma drainage device; additional glaucoma surgery; reoperation; corneal graft; POSTOPERATIVE COMPLICATIONS; MEDICARE BENEFICIARIES; TRABECULECTOMY TVT; TREATMENT OUTCOMES; BAERVELDT; TUBE;
D O I
10.1097/IJG.0000000000001827
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Precis: In this longitudinal study of patients with open-angle (OAG), pseudoexfoliative (PXE), or neovascular glaucoma (NVG) receiving glaucoma drainage devices (GDD), posttube cumulative rates of reoperation, corneal graft, and visually threatening complications (VT-complications) increased beyond 5 years and were not significantly affected by glaucoma type. Purpose: To study the need for additional glaucoma surgery and development of complications after first GDD surgery in eyes with primary OAG, PXE, or NVG glaucoma. Patients and Methods: There were 306 eyes with OAG (n=185), PXE (n=60), or NVG (n=61) glaucoma who received a first GDD between 1996 and 2017. Outcomes including glaucoma reoperation, corneal graft procedure, and VT-complications after GDD were measured. Kaplan-Meier analysis was used to compare cumulative rate of reaching outcomes over time after GDD placement among the 3 glaucoma groups. Results: When comparing the OAG, PXE, and NVG groups, there were no significant differences in post-GDD cumulative rates of reoperation (P=0.33), corneal graft (P=0.26), or VT-complications (P=0.65) over time. For all eyes, the overall cumulative rates for each outcome measure increased beyond 5 years, and specific Kaplan-Meier rates (5-y, 10-y) included: reoperation (16%, 25%), corneal graft (6%, 12%), VT-complications (9%, 14%). When comparing specific GDDs, the Ahmed FP7 had a higher cumulative reoperation rate over time compared with the Baerveldt 350 (P=0.019). Conclusion: Glaucoma type did not significantly affect post-GDD cumulative rates of reoperation, corneal graft, and VT-complication among the OAG, PXE, and NVG groups. For all eyes, cumulative rates of reoperation, corneal graft, and VT-complications increased beyond 5 years. The Ahmed FP7 had a significantly higher cumulative reoperation rate compared with the Baerveldt 350 over time.
引用
收藏
页码:508 / 514
页数:7
相关论文
共 50 条
  • [31] Choroidal Effusions after Glaucoma Drainage Implant Surgery
    Ying, Stephanie
    Coulon, Sara J.
    Lidder, Alcina K.
    Labowsky, Mary
    Cheng, Christopher P.
    Vinod, Kateki
    Sidoti, Paul A.
    Panarelli, Joseph F.
    [J]. OPHTHALMOLOGY GLAUCOMA, 2023, 6 (05): : 530 - 540
  • [32] Outcomes of reimplantation of a new Glaucoma Drainage Device after explantation of an older implant from exposure-related complications
    Yaswanth, Tiruveedhi S.
    Roy, Avik K.
    Senthil, Sirisha D.
    Krishnamurthy, Rashmi S.
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (10) : 3352 - 3356
  • [33] Membrane-tube-type glaucoma shunt device for refractory glaucoma surgery
    Han, Jong Chul
    Hwang, Young Hoon
    Ahn, Byung Heon
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (01) : 163 - 169
  • [34] The Effect of Suture Wick Technique on Early Intraocular Pressure Control After Nonvalved (Baerveldt 350) Glaucoma Drainage Device Surgery
    Rothman, Adam L.
    An, Selena J.
    Herndon, Leon W., Jr.
    [J]. JOURNAL OF GLAUCOMA, 2018, 27 (12) : 1145 - 1150
  • [35] Analytical model for managing hypotony after implantation surgery of a glaucoma drainage device
    R. Agujetas
    B. Kudiesh
    J. I. Fernández-Vigo
    Julián García-Feijóo
    J. M. Montanero
    [J]. Biomechanics and Modeling in Mechanobiology, 2021, 20 : 2061 - 2070
  • [36] Concurrent adjacent strabismus surgery with glaucoma drainage device placement in childhood glaucomas
    Jacobson, Adam
    Bohnsack, Brenda L.
    [J]. BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [37] Capsule excision and Ologen™ implantation for revision after glaucoma drainage device surgery
    Rosentreter, Andre
    Mellein, Anne C.
    Konen, Walter W.
    Dietlein, Thomas S.
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (09) : 1319 - 1324
  • [38] Concurrent adjacent strabismus surgery with glaucoma drainage device placement in childhood glaucomas
    Adam Jacobson
    Brenda L. Bohnsack
    [J]. BMC Ophthalmology, 24
  • [39] Capsule excision and Ologen™ implantation for revision after glaucoma drainage device surgery
    André Rosentreter
    Anne C. Mellein
    Walter W. Konen
    Thomas S. Dietlein
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 1319 - 1324
  • [40] Revision surgery in episcleral glaucoma drainage devices
    Rosentreter, A.
    Dietlein, T. S.
    [J]. OPHTHALMOLOGE, 2016, 113 (11): : 906 - 909