Metrology for Dual Taper Total Hip Arthroplasty

被引:3
|
作者
Van Citters, Douglas W. [1 ]
Assael, Dylan J. [1 ]
Currier, John H. [1 ]
机构
[1] Thayer Sch Engn Dartmouth, 14 Engn Dr, Hanover, NH 03755 USA
来源
MODULARITY AND TAPERS IN TOTAL JOINT REPLACEMENT DEVICES | 2015年 / 1591卷
关键词
taper corrosion; metrology; arthroplasty; IN-VIVO CORROSION; ON-METAL BEARINGS; JUNCTION; WEAR;
D O I
10.1520/STP159120140137
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recent hip implant designs have included modular necks to offer surgeons the ability to optimally suit each patient's unique anatomy. Certain designs have experienced high rates of adverse local tissue reactions secondary to suspected corrosion at the additional modular taper of the stem-neck interface. This study used a coordinate measuring machine to determine the volumetric material loss at this interface in a single such design. Because of the unique geometry of this dual-taper design, a computational approach was developed to reverse engineer the as-manufactured geometry and report the amount of material released into the patient's joint space. Approximately 90 % of the total volume loss in the taper interface can be attributed to the male component. Volumetric cobalt-chromium-molybdenum loss rates are estimated to exceed 2.3 mm(3)/year (95 % confidence interval [C.I.]: 1.67-2.96 mm(3)/year) and are of similar magnitude to rates identified for material loss in metal-on-metal hips. The average rate of material loss in vivo is thus of clinical relevance in the context of the observed adverse outcomes.
引用
收藏
页码:164 / 180
页数:17
相关论文
共 50 条
  • [1] Early Outcomes of Revision Surgery for Taper Corrosion of Dual Taper Total Hip Arthroplasty in 187 Patients
    Dimitriou, Dimitris
    Liow, Ming Han Lincoln
    Tsai, Tsung-Yuan
    Leone, William A.
    Li, Guoan
    Kwon, Young-Min
    JOURNAL OF ARTHROPLASTY, 2016, 31 (07): : 1549 - 1554
  • [2] Taper corrosion: a complication of total hip arthroplasty
    Morlock, Michael M.
    Hube, Robert
    Wassilew, Georgi
    Prange, Felix
    Huber, Gerd
    Perka, Carsten
    EFORT OPEN REVIEWS, 2020, 5 (11) : 776 - 784
  • [3] Do Stem Taper Microgrooves Influence Taper Corrosion in Total Hip Arthroplasty? A Matched Cohort Retrieval Study
    Arnholt, Christina M.
    MacDonald, Daniel W.
    Underwood, Richard J.
    Guyer, Eric P.
    Rimnac, Clare M.
    Kurtz, Steven M.
    Mont, Michael A.
    Klein, Gregg R.
    Lee, Gwo-Chin
    Chen, Antonia F.
    Hamlin, Brian R.
    Cates, Harold E.
    Malkani, Arthur L.
    Kraay, Matthew J.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (04): : 1363 - 1373
  • [4] Effect of Taper Design on Trunnionosis in Metal on Polyethylene Total Hip Arthroplasty
    Tan, Sok Chuen
    Teeter, Matthew G.
    Del Balso, Christopher
    Howard, James L.
    Lanting, Brent A.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (07): : 1269 - 1272
  • [5] Evaluation of the Painful Dual Taper Modular Neck Stem Total Hip Arthroplasty: Do They All Require Revision?
    Kwon, Young-Min
    JOURNAL OF ARTHROPLASTY, 2016, 31 (07): : 1385 - 1389
  • [6] Sensitivity and Specificity of Metal Ion Levels in Predicting "Pseudotumors" due to Taper Corrosion in Patients With Dual Taper Modular Total Hip Arthroplasty
    Kwon, Young-Min
    Tsai, Tsung-Yuan
    Leone, William A.
    Liow, Ming Han Lincoln
    JOURNAL OF ARTHROPLASTY, 2017, 32 (03): : 996 - 1000
  • [7] Taper corrosion in total hip arthroplasty - How to assess and which design features are crucial?
    Mueller, Ulrike
    Bormann, Therese
    Schroeder, Stefan
    Renkawitz, Tobias
    Kretzer, J. Philippe
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 133
  • [8] Role of corrosion in taper failure and head disassociation in total hip arthroplasty of a single design
    Martin, Audrey J.
    Jenkins, Derek R.
    van Citters, Douglas W.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2018, 36 (11) : 2996 - 3003
  • [9] Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty
    Mai, Phuong Thao
    Bormann, Therese
    Mueller, Ulrike
    Kretzer, Jan Philippe
    Gibmeier, Jens
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 128
  • [10] Head Taper Corrosion Causing Head Bottoming Out and Consecutive Gross Stem Taper Failure in Total Hip Arthroplasty
    Morlock, Michael M.
    Dickinson, Emilie C.
    Guenther, Klaus-Peter
    Buente, Dennis
    Polster, Valerie
    JOURNAL OF ARTHROPLASTY, 2018, 33 (11): : 3581 - 3590