Preparative separation of monoclonal antibody aggregates by cation-exchange laterally-fed membrane chromatography

被引:19
|
作者
Madadkar, Pedram [1 ]
Sadavarte, Rahul [1 ]
Butler, Michael [2 ]
Durocher, Yves [3 ,4 ]
Ghosh, Raja [1 ]
机构
[1] McMaster Univ, Dept Chem Engn, Hamilton, ON L8S 4L7, Canada
[2] Univ Manitoba, Dept Microbiol, Winnipeg, MB R3T 2N2, Canada
[3] Natl Res Council Canada, Montreal, PQ H4P 2R2, Canada
[4] Univ Montreal, Fac Med, Dept Biochim & Med Mol, Montreal, PQ, Canada
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2017年 / 1055卷
基金
加拿大自然科学与工程研究理事会;
关键词
Monoclonal antibody; Aggregates; Membrane chromatography; Device; Protein purification; Bioseparation; SIZE-EXCLUSION CHROMATOGRAPHY; PROTEIN SEPARATION; POLYETHYLENE-GLYCOL; HIGH-RESOLUTION; PURIFICATION; REMOVAL; FRACTIONATION; EXPRESSION; QUALITY; DESIGN;
D O I
10.1016/j.jchromb.2017.04.036
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cation exchange (CEX) chromatography is widely used for large-scale separation of monoclonal antibody (mAb) aggregates. The aggregates bind more strongly to CEX media and hence elute after the monomeric mAb in a salt gradient. However, monomer-aggregate resolution that is typically obtained is poor, which results in low product recovery. In the current study we address this challenge through the use of cation-exchange laterally-fed membrane chromatography (LFMC). Three different LFMC devices, each containing a bed of strong cation exchange (S) membranes were used for preparative-scale removal of mAb aggregates. Trastuzumab (IgG1) biosimilar derived from human embryonic kidney 293 (293) cells was used as the primary model mAb in our study. The other mAbs investigated were Chinese hamster ovary (CHO) cell line derived Alemtuzumab (Campath-1H) and a heavy chain chimeric mAb EG2-hFc. In each of these case-studies, aggregates were well resolved from the respective monomer. The separated and collected monomer and aggregate fractions were analyzed using techniques such as hydrophobic interaction membrane chromatography (HIMC), native polyacrylamide gel electrophoresis (or PAGE), and size-exclusion high-performance liquid chromatography (SE-HPLC). The high efficiency of separation obtained in each case was due to a combination of the small membrane pore size (3-5 mu m), and the use of LFMC technology, which has been shown to be suitable for high resolution, multi-component protein separations. Also, the LFMC based separation processes reported in this study were more than an order of magnitude faster than equivalent resin-based, cation exchange chromatography.
引用
收藏
页码:158 / 164
页数:7
相关论文
共 50 条
  • [1] Rapid preparative separation of monoclonal antibody charge variants using laterally-fed membrane chromatography
    Sadavarte, Rahul
    Madadkar, Pedram
    Filipe, Carlos D. M.
    Ghosh, Raja
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1073 : 27 - 33
  • [2] On the workings of laterally-fed membrane chromatography
    Ghosh, Raja
    Madadkar, Pedram
    Wu, Qijiayu
    JOURNAL OF MEMBRANE SCIENCE, 2016, 516 : 26 - 32
  • [3] Purification of monoclonal antibody using cation exchange z2 laterally-fed membrane chromatography - A potential alternative to protein A affinity chromatography
    Roshankhah, Roxana
    Chen, Guoqiang
    Xu, Yating
    Butani, Nikhila
    Durocher, Yves
    Pelton, Robert
    Ghosh, Raja
    BIOCHEMICAL ENGINEERING JOURNAL, 2022, 178
  • [4] A laterally-fed membrane chromatography module
    Madadkar, Pedram
    Wu, Qijiayu
    Ghosh, Raja
    JOURNAL OF MEMBRANE SCIENCE, 2015, 487 : 173 - 179
  • [5] High-resolution, preparative purification of PEGylated protein using a laterally-fed membrane chromatography device
    Madadkar, Pedram
    Nino, Sergio Luna
    Ghosh, Raja
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1035 : 1 - 7
  • [6] Computational fluid dynamic (CFD) simulation of laterally-fed membrane chromatography
    Umatheva, Umatheny
    Madadkar, Pedram
    Selvaganapathy, P. Ravi
    Ghosh, Raja
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2018, 137 : 412 - 420
  • [7] High-resolution protein separation using a laterally-fed membrane chromatography device
    Madadkar, Pedram
    Ghosh, Raja
    JOURNAL OF MEMBRANE SCIENCE, 2016, 499 : 126 - 133
  • [8] Performance Comparison of a Laterally-Fed Membrane Chromatography (LFMC) Device with a Commercial Resin Packed Column
    Madadkar, Pedram
    Sadavarte, Rahul
    Ghosh, Raja
    MEMBRANES, 2019, 9 (11)
  • [9] Purification of therapeutic adenoviruses using laterally-fed membrane chromatography
    Kawka, Karina
    Madadkar, Pedram
    Umatheva, Umatheny
    Shoaebargh, Shabnam
    Medina, Maria Fe C.
    Lichty, Brian D.
    Ghosh, Raja
    Latulippe, David R.
    JOURNAL OF MEMBRANE SCIENCE, 2019, 579 : 351 - 358
  • [10] Coupling cation and anion exchange chromatography for fast separation of monoclonal antibody charge variants
    Zimoch-Rumanek, Patrycja
    Antos, Dorota
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1733