Validity of goniometric joint measurements in cats

被引:55
作者
Jaeger, Gayle H.
Marcellin-Little, Denis J.
DePuy, Venita
Lascelles, B. Duncan X.
机构
[1] N Carolina State Univ, Coll Vet Med, Dept Clin Sci, Comparat Pain Res Lab, Raleigh, NC 27606 USA
[2] N Carolina State Univ, Coll Vet Med, Dept Clin Sci, Orthoped Res Lab, Raleigh, NC 27606 USA
[3] Calif Vet Specialists, San Marcos, CA 92069 USA
[4] INC Res, Biostat, Raleigh, NC 27609 USA
关键词
D O I
10.2460/ajvr.68.8.822
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To compare and validate goniometric joint measurements obtained from nonsedated and sedated cats with measurements from radiographic evaluation. Animals-20 adult cats with no evidence of joint disease. Procedures-Measurements of flexion and extension of the carpus, elbow, shoulder, tarsus, stifle, and hip joints and of carpal and tarsal joints during varus and valgus angulation were made by a single investigator before and after sedation of cats. Measurements were made by use of a goniometer with a masked dial. Joint angle measurements were compared between nonsedated and sedated cats and also with measurements from radiographs made while cats were sedated. Each series of measurements was repeated 4 times. To evaluate repeatability, Cronbach alpha values were calculated for repeated measure results of goniometric joint measurements of nonsedated and sedated cats. An intraclass correlation was calculated to determine reliability among the 3 measurement types (ie, measurements from nonsedated and sedated cats and on radiographic evaluation). Results-Joint measurements did not differ significantly by measurement type, when comparing radiographic measurements with goniometric measurements in sedated and nonsedated cats. Cronbach a values were > 0.99 for goniometric joint measurements within individual nonsedated and sedated cats and also for comparison of mean meaurements obtained from sedated cats versus nonsedated cats versus radiographs. An intraclass correlation of 0.999 revealed high reliability among measurement types. Conclusions and Clinical Relevance-Results indicated that goniometric joint measurements in nonsedated and sedated cats are repeatable and valid.
引用
收藏
页码:822 / 826
页数:5
相关论文
共 29 条
[1]   Repeatability of goniometer measurements of the knee in patients wearing an Ilizarov external fixator: a clinic-based study [J].
Barker, KL ;
Lamb, SE ;
Burns, M ;
Simpson, AHRW .
CLINICAL REHABILITATION, 1999, 13 (02) :156-163
[2]   Cronbach's alpha [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1997, 314 (7080) :572-572
[3]   RELIABILITY OF GONIOMETRIC MEASUREMENTS [J].
BOONE, DC ;
AZEN, SP ;
LIN, CM ;
SPENCE, C ;
BARON, C ;
LEE, L .
PHYSICAL THERAPY, 1978, 58 (11) :1355-1360
[4]  
BOUCK GR, 1995, VET COMP ORTHOPAED, V8, P177
[5]   Prevalence of radiographic signs of degenerative joint disease in a hospital population of cats [J].
Clarke, S. P. ;
Mellor, D. ;
Clements, D. N. ;
Gemmill, T. ;
Farrell, M. ;
Carmichael, S. ;
Bennett, D. .
VETERINARY RECORD, 2005, 157 (25) :793-799
[6]   Fluoroscopically guided closed reduction and internal fixation of fractures of the lateral portion of the humeral condyle: Prospective clinical study of the technique and results in ten dogs [J].
Cook, JL ;
Tomlinson, JL ;
Reed, AL .
VETERINARY SURGERY, 1999, 28 (05) :315-321
[7]   EVALUATION OF POLYSULFATED GLYCOSAMINOGLYCAN FOR THE TREATMENT OF HIP-DYSPLASIA IN DOGS [J].
DEHAAN, JJ ;
GORING, RL ;
BEALE, BS .
VETERINARY SURGERY, 1994, 23 (03) :177-181
[8]  
ENWEMEKA CS, 1986, SCAND J REHABIL MED, V18, P47
[9]   CLINICAL MEASUREMENT OF RANGE OF MOTION - REVIEW OF GONIOMETRY EMPHASIZING RELIABILITY AND VALIDITY [J].
GAJDOSIK, RL ;
BOHANNON, RW .
PHYSICAL THERAPY, 1987, 67 (12) :1867-1872
[10]   Osteoarthritis in cats: a retrospective radiological study [J].
Godfrey, DR .
JOURNAL OF SMALL ANIMAL PRACTICE, 2005, 46 (09) :425-429