A new method of studying buried steel corrosion and its inhibition using the wire beam electrode

被引:61
作者
Aung, NN [1 ]
Tan, YJ [1 ]
机构
[1] Nanyang Technol Univ, Sch Mat Engn, Div Mat Sci, Corros & NDT Res Grp, Singapore 639798, Singapore
关键词
localised corrosion; inhibitor; wire bearn electrode; steel; buried steel corrosion;
D O I
10.1016/j.corsci.2004.04.010
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
An electrochemically integrated multi-electrode system namely the wire beam electrode (WBE) has been applied for the first time to study corrosion of mild steel buried in sand, with and without the presence of corrosion inhibitor potassium dichromate (K2Cr2O7)- Measurements of galvanic current distribution maps have been carried out during the exposure of the WBE to dry, damp and chlorinated sand environments. Characteristic changes in galvanic current distribution maps have been observed during the initiation and propagation of localised corrosion. Specifically, during corrosion initiation in damped sand, new anodes were found to initiate and corrosion appeared to be in general form. When the WBE was later exposed to chlorinated sand, massive disappearance of anodic sites was found to occur, resulting in accelerated anodic dissolution of a small number of remaining anodic sites. Addition of corrosion inhibitor K2Cr2O7 to the sand environment was found to significantly reduce galvanic current only after an initial increase in galvanic current. This result suggests that KICI-107 behaved as an anodic inhibitor. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3057 / 3067
页数:11
相关论文
共 20 条
[1]   PRELIMINARY TESTING OF NA2PO3F AS A CURATIVE CORROSION-INHIBITOR FOR STEEL REINFORCEMENTS IN CONCRETE [J].
ANDRADE, C ;
ALONSO, C ;
ACHA, M ;
MALRIC, B .
CEMENT AND CONCRETE RESEARCH, 1992, 22 (05) :869-881
[2]  
*ASTM, 1991, C876 ASTM, P425
[3]  
AUNG NN, UNPUB CORROS SCI
[4]   Ultrasonic study for detection of inner diameter cracking in pipeline girth welds using creeping waves [J].
Baby, S ;
Balasubramanian, T ;
Pardikar, RJ .
INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2003, 80 (02) :139-146
[5]  
BAGHABRA OS, 1993, CEM CONC RES, V23, P139
[6]  
Broomfield J.P., 1997, CORROSION STEEL CONC
[7]   The use of permanent corrosion monitoring in new and existing reinforced concrete structures [J].
Broomfield, JP ;
Kevin, DB ;
Hladky, K .
CEMENT & CONCRETE COMPOSITES, 2002, 24 (01) :27-34
[8]   A STUDY OF REINFORCEMENT BEHAVIOR IN CONCRETE STRUCTURES USING ELECTROCHEMICAL TECHNIQUES [J].
CIGNA, R ;
PROVERBIO, E ;
ROCCHINI, G .
CORROSION SCIENCE, 1993, 35 (5-8) :1579-1584
[9]   CRITICAL SOIL-MOISTURE CONTENT IN THE UNDERGROUND CORROSION OF MILD-STEEL [J].
GUPTA, SK ;
GUPTA, BK .
CORROSION SCIENCE, 1979, 19 (03) :171-178
[10]   ELECTROCHEMICAL IMPEDANCE FOR A LARGE STRUCTURE IN SOIL [J].
HARUYAMA, S ;
SUDO, S .
ELECTROCHIMICA ACTA, 1993, 38 (14) :1857-1865