Stability changes of dental implants according to the simulated peri-implant bone defects

被引:0
|
作者
Park, Chan-Jin [1 ]
Lee, Mi-Ran [1 ]
Cho, Lee-Ra [1 ]
Yi, Yang-Jin [1 ]
Jung, Ho-Nyun [2 ]
机构
[1] Kangnung Natl Univ, Coll Dent, Dept Prosthodont, Jibyun-dong 123, Kangnung, South Korea
[2] Korea Food & Drug Adm, Seoul 122704, South Korea
来源
ASBM7: ADVANCED BIOMATERIALS VII | 2007年 / 342-343卷
关键词
dental implant; gray values; radiography; resonance frequency analysis;
D O I
10.4028/www.scientific.net/KEM.342-343.57
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Twenty implants of 3.75mm in diameter(Neoplant, Neobiotech, Korea) were used to evaluate the correlation between the resonance frequency analysis (RFA) and the radiographic method for perimplant bone change under in vitro conditions. To simulate peri-implant bone change, 2mm-deep 45 degrees range horizontal defect and 2mm-deep 90 degrees range horizontal defect area were serially prepared perpendicular to the X-ray beam after conventional implant insertion. ISQ values and gray values inside threads were measured before and after peri-implant bone defect preparation. ISQ value of resonance frequency analysis was changed according to peri-implant bone (hange and gray value of radiographic method was changed according to peri-implant bone change. In horizontal defect condition, relatively positive correlation were between ISQ and gray values r=0.663).
引用
收藏
页码:57 / +
页数:2
相关论文
共 50 条
  • [41] Finite element analysis of the stress distributions in peri-implant bone in modified and standard-threaded dental implants
    Dundar, Serkan
    Topkaya, Tolga
    Solmaz, Murat Yavuz
    Yaman, Ferhan
    Atalay, Yusuf
    Saybak, Arif
    Asutay, Fatih
    Cakmak, Omer
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2016, 30 (01) : 127 - 133
  • [42] Mineralization and morphology of peri-implant bone around loaded and unloaded dental implants retrieved from the human mandible
    Zamparini, Fausto
    Gandolfi, Maria Giovanna
    Spinelli, Andrea
    Ferri, Mauro
    Iezzi, Giovanna
    Botticelli, Daniele
    Prati, Carlo
    ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2024, 28 (02): : 623 - 637
  • [43] Peri-implant bone changes following tooth extraction, immediate placement and loading of implants in the edentulous maxilla
    Lieven Barbier
    Johan Abeloos
    Calix De Clercq
    Reinhilde Jacobs
    Clinical Oral Investigations, 2012, 16 : 1061 - 1070
  • [44] Treatment of Peri-implant Bone Defects with Platelet-Rich Fibrin
    Hamzacebi, Burak
    Oduncuoglu, Bahar
    Alaaddinoglu, Emine Elif
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2015, 35 (03) : 415 - 422
  • [45] Application of The bFGF and β-TCP Complex to Peri-Implant Bone Defects in Dogs
    Takagi, Masashi
    Kanayama, Keiichi
    Mukai, Keisuke
    Morinaga, Hirotsugu
    Shibatsuji, Atsushi
    Shibutani, Toshiaki
    JOURNAL OF HARD TISSUE BIOLOGY, 2020, 29 (02) : 105 - 110
  • [46] Probing at implants with peri-implantitis and its relation to clinical peri-implant bone loss
    Serino, Giovanni
    Turri, Alberto
    Lang, Niklaus P.
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (01) : 91 - 95
  • [47] Randomized Controlled Study on Effect of Concentrated Growth Factors on Crestal Bone Levels and Peri-implant Bone Density in Dental Implants
    Karthik, V. C.
    Prabhu, K.
    Bharath, N.
    Shobana, P.
    Indhu, K.
    Abraham, Sonia
    Arunalakshmi, K.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2022, 14 : 68 - 77
  • [48] Peri-implant complications for posterior endosteal implants
    Esquivel-Upshaw, Josephine
    Mehler, Alex
    Clark, Arthur
    Neal, Dan
    Gonzaga, Luiz
    Anusavice, Kenneth
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (12) : 1390 - 1396
  • [49] Relationship between dental implant stability determined by resonance frequency analysis measurements and peri-implant vertical defects:: an in vitro study
    Tozum, T. F.
    Turkyilmaz, I.
    McGlumphy, E. A.
    JOURNAL OF ORAL REHABILITATION, 2008, 35 (10) : 739 - 744
  • [50] Osteogenic Ability According to the Decalcified Modality of Auto-Tooth Bone Grafts in Peri-Implant Defects in Dogs
    Jang, Han-Seung
    Kim, Su-Gwan
    Lim, Sung-Chul
    Oh, Ji-Su
    Jeong, Mi-Ae
    Kim, Jin-Son
    IMPLANT DENTISTRY, 2014, 23 (04) : 482 - 488