Stability changes of dental implants according to the simulated peri-implant bone defects

被引:0
作者
Park, Chan-Jin [1 ]
Lee, Mi-Ran [1 ]
Cho, Lee-Ra [1 ]
Yi, Yang-Jin [1 ]
Jung, Ho-Nyun [2 ]
机构
[1] Kangnung Natl Univ, Coll Dent, Dept Prosthodont, Jibyun-dong 123, Kangnung, South Korea
[2] Korea Food & Drug Adm, Seoul 122704, South Korea
来源
ASBM7: ADVANCED BIOMATERIALS VII | 2007年 / 342-343卷
关键词
dental implant; gray values; radiography; resonance frequency analysis;
D O I
10.4028/www.scientific.net/KEM.342-343.57
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Twenty implants of 3.75mm in diameter(Neoplant, Neobiotech, Korea) were used to evaluate the correlation between the resonance frequency analysis (RFA) and the radiographic method for perimplant bone change under in vitro conditions. To simulate peri-implant bone change, 2mm-deep 45 degrees range horizontal defect and 2mm-deep 90 degrees range horizontal defect area were serially prepared perpendicular to the X-ray beam after conventional implant insertion. ISQ values and gray values inside threads were measured before and after peri-implant bone defect preparation. ISQ value of resonance frequency analysis was changed according to peri-implant bone (hange and gray value of radiographic method was changed according to peri-implant bone change. In horizontal defect condition, relatively positive correlation were between ISQ and gray values r=0.663).
引用
收藏
页码:57 / +
页数:2
相关论文
共 50 条
  • [21] Changes in Peri-implant Marginal Bone Level by Jaw Location: A Systematic Review and Meta-Analysis of 4970 Implants
    Ghaly, Mira
    Tarrazzi, Daler
    Xia, Veronica
    Tharrington, Shafer
    Schoenbaum, Todd R.
    JOURNAL OF ORAL IMPLANTOLOGY, 2023, 49 (04) : 444 - 455
  • [22] Stress Related Peri-Implant Bone Loss
    Flanagan, Dennis
    JOURNAL OF ORAL IMPLANTOLOGY, 2010, 36 (04) : 325 - 327
  • [23] Bone formation in peri-implant defects grafted with microparticles: a pilot animal experimental study
    Moest, Tobias
    Koehler, Franz
    Prechtl, Christopher
    Schmitt, Christian
    Watzek, Georg
    Schlegel, Karl Andreas
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2014, 41 (10) : 990 - 998
  • [24] ACCURACY OF HIGH-FREQUENCY ULTRASOUND SCANNER IN DETECTING PERI-IMPLANT BONE DEFECTS
    Bohner, Lauren
    Habor, Daniel
    Gremse, Felix
    Tortamano, Pedro
    Wolfart, Stefan
    Marotti, Juliana
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (03) : 650 - 659
  • [25] Management of extensive peri-implant defects with titanium meshes
    Mahdi Kadkhodazadeh
    Reza Amid
    Anahita Moscowchi
    Oral and Maxillofacial Surgery, 2021, 25 : 561 - 568
  • [26] Management of extensive peri-implant defects with titanium meshes
    Kadkhodazadeh, Mahdi
    Amid, Reza
    Moscowchi, Anahita
    ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2021, 25 (04): : 561 - 568
  • [27] Evaluation of the Peri-Implant Bone Level around Platform-Switched Dental Implants: A Retrospective 3-Year Radiographic Study
    Pan, Yu Hwa
    Lin, His Kuei
    Lin, Jerry C-Y
    Hsu, Yung-Szu
    Wu, Yi-Fan
    Salamanca, Eisner
    Chang, Wei-Jen
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (14)
  • [28] Sonography in the diagnosis of peri-implant bone defects: An in vitro study on native human mandibles
    Bykhovsky, Igor
    Hildner, Alexander
    Kripfgans, Oliver D.
    Mengel, Reiner
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (09) : 1128 - 1137
  • [29] The role of peri-implant strains in dental implant systems: a narrative review
    Weiner, Saul
    Bashiri, Rafiullah
    Wang, Hongjun
    FRONTIERS OF ORAL AND MAXILLOFACIAL MEDICINE, 2023, 5
  • [30] Biomechanical analysis of triply periodic minimal surfaces-based porous dental implants versus solid implants: impact of peri-implant bone density on micromotion
    Sharma, Deepak
    Sharma, Varun
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2025,