Purpose: The aim of this study was to evaluate the clinical fracture rate of crowns fabricated with the pressable, leucite-reinforced ceramic IPS Empress, and relate the results to the type of tooth restored. Materials and Methods: The database SCOPUS was searched for clinical studies involving full-coverage crowns made of IFS Empress. To assess the fracture rate of the crowns in relation to the type of restored tooth and study, Poisson regression analysis was used. Results: Seven clinical studies were identified involving 1,487 adhesively luted crowns (mean observation time: 4.5 +/- 1.7 years) and 81 crowns cemented with zinc-phosphate cement (mean observation time: 1.6 +/- 0.8 years). Fifty-seven of the adhesively luted crowns fractured (3.8%). The majority of fractures (62%) occurred between the third and sixth year after placement. There was no significant influence regarding the test center on fracture rate, but the restored tooth type played a significant role. The hazard rate (per year) for crowns was estimated to be 5 in every 1,000 crowns for incisors, 7 in every 1,000 crowns for premolars, 12 in every 1,000 crowns for canines, and 16 in every 1,000 crowns for molars. One molar crown in the zinc-phosphate group fractured after 1.2 years. Conclusion: Adhesively luted IFS Empress crowns showed a low fracture rate for incisors and premolars and a somewhat higher rate for molars and canines. The sample size of the conventionally luted crowns was too small and the observation period too short to draw meaningful conclusions. Int J Prosthodont 2010;23:129-133.
引用
收藏
页码:129 / 133
页数:5
相关论文
共 32 条
  • [1] Albakry Mohammad, 2004, J Prosthodont, V13, P141, DOI 10.1111/j.1532-849X.2004.04025.x
  • [2] Blatz MB, 2002, QUINTESSENCE INT, V33, P415
  • [3] Boning K., 2006, Dtsch Zahnarztl Z, V61, P604
  • [4] EDELHOFF D, 2000, DTSCH ZAHNARZTL Z, V55, P326
  • [5] El-Mowafy Omar, 2002, J Can Dent Assoc, V68, P233
  • [6] Esquivel-Upshaw JF, 2008, INT J PROSTHODONT, V21, P155
  • [7] Fradeani M, 2005, QUINTESSENCE INT, V36, P105
  • [8] Fradeani M, 2002, QUINTESSENCE INT, V33, P503
  • [9] Clinical evaluation of all-ceramic crowns
    Gemalmaz, D
    Ergin, S
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (02) : 189 - 196
  • [10] Clinical complications in fixed prosthodontics
    Goodacre, CJ
    Bernal, G
    Rungcharassaeng, K
    Kan, JYK
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (01) : 31 - 41