Volume of Preclinical Xenograft Tumors Is More Accurately Assessed by Ultrasound Imaging Than Manual Caliper Measurements

被引:83
作者
Ayers, Gregory D. [2 ]
McKinley, Eliot T. [3 ]
Zhao, Ping
Fritz, Jordan M.
Metry, Rebecca E.
Deal, Brenton C.
Adlerz, Katrina M.
Coffey, Robert J. [5 ]
Manning, H. Charles [1 ,3 ,4 ,6 ,7 ]
机构
[1] Vanderbilt Univ, Sch Med, Inst Imaging Sci, Med Ctr, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Med Ctr, Dept Biostat, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Med Ctr, Dept Biomed Engn, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Med Ctr, Dept Radiol & Radiol Sci, Nashville, TN 37232 USA
[5] Vanderbilt Univ, Med Ctr, Dept Med, Nashville, TN 37232 USA
[6] Vanderbilt Univ, Med Ctr, Dept Neurosurg, Nashville, TN 37232 USA
[7] Vanderbilt Univ, Med Ctr, Program Chem & Phys Biol, Nashville, TN 37232 USA
关键词
colorectal cancer; preclinical mouse models; tumor burden; ultrasound imaging; xenograft; THERAPEUTIC RESPONSE; COLORECTAL-CANCER; NUDE-MICE; GROWTH; MOUSE; MODELS; SYSTEM;
D O I
10.7863/jum.2010.29.6.891
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. The volume of subcutaneous xenograft tumors is an important metric of disease progression and response to therapy in preclinical drug development. Noninvasive imaging technologies suitable for measuring xenograft volume are increasingly available, yet manual calipers, which are susceptible to inaccuracy and bias, are routinely used. The goal of this study was to quantify and compare the accuracy, precision, and inter-rater variability of xenograft tumor volume assessment by caliper measurements and ultrasound imaging. Methods. Subcutaneous xenograft tumors derived from human colorectal cancer cell lines (DLD1 and SW620) were generated in athymic nude mice. Experienced independent reviewers segmented 3-dimensional ultrasound data sets and collected manual caliper measurements resulting in tumor volumes. Imaging- and caliper-derived volumes were compared with the tumor mass, the reference standard, determined after resection. Bias, precision, and inter-rater differences were estimated for each mouse among reviewers. Bootstrapping was used to estimate mean and confidence intervals of variance components, intraclass correlation coefficients (ICCs), and confidence intervals for each source of variation. Results. The average deviation from the true volume and inter-rater differences were significantly lower for ultrasound volumes compared with caliper volumes (P =.0005 and .001, respectively). Reviewer ICCs for ultrasound and caliper measurements were similarly low (1%), yet caliper volume variance was 1.3-fold higher than for ultrasound. Conclusions. Ultrasound imaging more accurately, precisely, and reproducibly reflects xenograft tumor volume than caliper measurements. These data suggest that preclinical studies using the xenograft burden as a surrogate end point measured by ultrasound imaging require up to 30% fewer animals to reach statistical significance compared with analogous studies using caliper measurements.
引用
收藏
页码:891 / 901
页数:11
相关论文
共 15 条
  • [11] Bioluminescent imaging (BLI) to improve and refine traditional murine models of tumor growth and metastasis
    Jenkins, DE
    Oei, Y
    Hornig, YS
    Yu, SF
    Dusich, J
    Purchio, T
    Contag, PR
    [J]. CLINICAL & EXPERIMENTAL METASTASIS, 2003, 20 (08) : 733 - 744
  • [12] Molecular Imaging of Therapeutic Response to Epidermal Growth Factor Receptor Blockade in Colorectal Cancer
    Manning, H. Charles
    Merchant, Nipun B.
    Foutch, A. Coe
    Virostko, John M.
    Wyatt, Shelby K.
    Shah, Chirayu
    McKinley, Eliot T.
    Xie, Jingping
    Mutic, Nathan J.
    Washington, M. Kay
    La Fleur, Bonnie
    Tantawy, Mohammed Noor
    Peterson, Todd E.
    Ansari, M. Sib
    Baldwin, Ronald M.
    Rothenberg, Mace L.
    Bornhop, Darryl J.
    Gore, John C.
    Coffey, Robert J.
    [J]. CLINICAL CANCER RESEARCH, 2008, 14 (22) : 7413 - 7422
  • [13] Mazurchuk R, 1997, CLIN CANCER RES, V3, P1635
  • [14] DETERMINATION OF SUBCUTANEOUS TUMOR SIZE IN ATHYMIC (NUDE) MICE
    TOMAYKO, MM
    REYNOLDS, CP
    [J]. CANCER CHEMOTHERAPY AND PHARMACOLOGY, 1989, 24 (03) : 148 - 154
  • [15] A new three-dimensional ultrasound microimaging technology for preclinical studies using a transgenic prostate cancer mouse model
    Wirtzfeld, LA
    Wu, GJ
    Bygrave, M
    Yamasaki, Y
    Sakai, H
    Moussa, M
    Izawa, JI
    Downey, DB
    Greenberg, NM
    Fenster, A
    Xuan, JW
    Lacefield, JC
    [J]. CANCER RESEARCH, 2005, 65 (14) : 6337 - 6345