Volume of Preclinical Xenograft Tumors Is More Accurately Assessed by Ultrasound Imaging Than Manual Caliper Measurements

被引:83
作者
Ayers, Gregory D. [2 ]
McKinley, Eliot T. [3 ]
Zhao, Ping
Fritz, Jordan M.
Metry, Rebecca E.
Deal, Brenton C.
Adlerz, Katrina M.
Coffey, Robert J. [5 ]
Manning, H. Charles [1 ,3 ,4 ,6 ,7 ]
机构
[1] Vanderbilt Univ, Sch Med, Inst Imaging Sci, Med Ctr, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Med Ctr, Dept Biostat, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Med Ctr, Dept Biomed Engn, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Med Ctr, Dept Radiol & Radiol Sci, Nashville, TN 37232 USA
[5] Vanderbilt Univ, Med Ctr, Dept Med, Nashville, TN 37232 USA
[6] Vanderbilt Univ, Med Ctr, Dept Neurosurg, Nashville, TN 37232 USA
[7] Vanderbilt Univ, Med Ctr, Program Chem & Phys Biol, Nashville, TN 37232 USA
关键词
colorectal cancer; preclinical mouse models; tumor burden; ultrasound imaging; xenograft; THERAPEUTIC RESPONSE; COLORECTAL-CANCER; NUDE-MICE; GROWTH; MOUSE; MODELS; SYSTEM;
D O I
10.7863/jum.2010.29.6.891
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. The volume of subcutaneous xenograft tumors is an important metric of disease progression and response to therapy in preclinical drug development. Noninvasive imaging technologies suitable for measuring xenograft volume are increasingly available, yet manual calipers, which are susceptible to inaccuracy and bias, are routinely used. The goal of this study was to quantify and compare the accuracy, precision, and inter-rater variability of xenograft tumor volume assessment by caliper measurements and ultrasound imaging. Methods. Subcutaneous xenograft tumors derived from human colorectal cancer cell lines (DLD1 and SW620) were generated in athymic nude mice. Experienced independent reviewers segmented 3-dimensional ultrasound data sets and collected manual caliper measurements resulting in tumor volumes. Imaging- and caliper-derived volumes were compared with the tumor mass, the reference standard, determined after resection. Bias, precision, and inter-rater differences were estimated for each mouse among reviewers. Bootstrapping was used to estimate mean and confidence intervals of variance components, intraclass correlation coefficients (ICCs), and confidence intervals for each source of variation. Results. The average deviation from the true volume and inter-rater differences were significantly lower for ultrasound volumes compared with caliper volumes (P =.0005 and .001, respectively). Reviewer ICCs for ultrasound and caliper measurements were similarly low (1%), yet caliper volume variance was 1.3-fold higher than for ultrasound. Conclusions. Ultrasound imaging more accurately, precisely, and reproducibly reflects xenograft tumor volume than caliper measurements. These data suggest that preclinical studies using the xenograft burden as a surrogate end point measured by ultrasound imaging require up to 30% fewer animals to reach statistical significance compared with analogous studies using caliper measurements.
引用
收藏
页码:891 / 901
页数:11
相关论文
共 15 条
  • [1] Three-dimensional ultrasound biomicroscopy for xenograft growth analysis
    Cheung, AMY
    Brown, AS
    Hastie, LA
    Cucevic, V
    Roy, M
    Lacefield, JC
    Fenster, A
    Foster, FS
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (06) : 865 - 870
  • [2] Multiple mouse biological loading and monitoring system for MRI
    Dazai, J
    Bock, NA
    Nieman, BJ
    Davidson, LM
    Henkelman, RM
    Chen, XJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) : 709 - 715
  • [3] Normal splenic volumes estimated using three-dimensional ultrasonography
    De Odorico, I
    Spaulding, KA
    Pretorius, DH
    Lev-Toaff, AS
    Bailey, TB
    Nelson, TR
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 1999, 18 (03) : 231 - 236
  • [4] TUMOR MEASUREMENT IN THE NUDE-MOUSE
    EUHUS, DM
    HUDD, C
    LAREGINA, M
    JOHNSON, FE
    [J]. JOURNAL OF SURGICAL ONCOLOGY, 1986, 31 (04) : 229 - 234
  • [6] Three-dimensional high-frequency ultrasound imaging for longitudinal evaluation of liver metastases in preclinical models
    Graham, KC
    Wirtzfeld, LA
    MacKenzie, LT
    Postenka, CO
    Groom, AC
    MacDonald, IC
    Fenster, A
    Lacefield, JC
    Chambers, AF
    [J]. CANCER RESEARCH, 2005, 65 (12) : 5231 - 5237
  • [7] Magnetic resonance imaging to measure therapeutic response using an orthotopic model of human pancreatic cancer
    He, ZQ
    Evelhoch, JL
    Mohammad, RM
    Adsay, NV
    Pettit, GR
    Vaitkevicius, VK
    Sarkar, FH
    [J]. PANCREAS, 2000, 21 (01) : 69 - 76
  • [8] Apoptosis signaling proteins as prognostic biomarkers in colorectal cancer: A review
    Hector, Suzanne
    Prehn, Jochen H. M.
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-REVIEWS ON CANCER, 2009, 1795 (02): : 117 - 129
  • [9] The accuracy of a new system for estimating organ volume using ultrasound
    Hughes, SW
    DArcy, TJ
    Maxwell, DJ
    Saunders, JE
    Chinn, S
    Sheppard, RJ
    [J]. PHYSIOLOGICAL MEASUREMENT, 1997, 18 (01) : 73 - 84
  • [10] Tumor response assessment is more robust with sequential CT scanning than external caliper measurements
    Ishimori, T
    Tatsumi, M
    Wahl, RL
    [J]. ACADEMIC RADIOLOGY, 2005, 12 (06) : 776 - 781