Application of lactate amperometric sol-gel biosensor to sequential injection determination of L-lactate

被引:24
作者
Gomes, Sofia Piedade
Odlozilikova, Martina
Almeida, M. Gabriela
Araujo, Alberto N.
Couto, Cristina M. C. M.
Montenegro, M. Conceicao B. S. M.
机构
[1] Univ Porto, REQUIMTE, Dept Quim Fis, Fac Farm, P-4099030 Oporto, Portugal
[2] ZENTIVA As, Prague 10237, Czech Republic
[3] Univ Nova Lisboa, Dept Quim, Fac Ciencias & Tecnol, REQUIMTE, P-2829516 Monte De Caparica, Portugal
[4] ISCS, Paredes, Portugal
关键词
LOx amperometric biosensor; sol-gel; SIA; pharmaceutical products;
D O I
10.1016/j.jpba.2006.11.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work describes the construction and evaluation of lactate sol-gel biosensors to accomplish the determination of lactate in pharmaceutical products. Lactate oxidase was incorporated in a porous sol-gel film placed onto a platinum-based electrode. Acid and basic catalysis were assessed. When coupled to a sequential injection system (SIA) the biosensor, based on (3-aminopropyl)trimethoxysilane, 2-(3,4-epoxycyclohexyl)ethyltrimethoxysilane, deionised water, polyethylene glycol 6000 and acid catalyst, presented a range of linearity of 5 x 10(-5) to 5 x 10(-3) M. The analytical usefulness of the developed biosensor was evaluated through analysis of commercial pharmaceutical products containing lactate with a sampling rate of 40 samples h(-1). The enzyme remained active for at least 30 days, enabling about 700 determinations without sensitivity decrease. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1376 / 1381
页数:6
相关论文
共 23 条
[1]  
Brett A. M. O., 1993, ELECTROCHEMISTRY PRI
[2]  
Brinker C.J., 1990, SOL GEL SCI
[3]   Application of a long shelf-life biosensor for the analysis of L-lactate in dairy products and serum samples [J].
Choi, MMF .
FOOD CHEMISTRY, 2005, 92 (03) :575-581
[4]   Application of amperometric sol-gel biosensor to flow injection determination of glucose [J].
Couto, CMCM ;
Araújo, AN ;
Montenegro, MCBSM ;
Rohwedder, J ;
Raimundo, I ;
Pasquini, C .
TALANTA, 2002, 56 (06) :997-1003
[5]   Evaluation of polycation-stabilized lactate oxidase in a silica sol-gel as a biosensor platform [J].
Cox, JA ;
Hensley, PM ;
Loch, CL .
MICROCHIMICA ACTA, 2003, 142 (1-2) :1-5
[6]   Prussian Blue- and lactate oxidase-based amperometric biosensor for lactic acid [J].
Garjonyte, R ;
Yigzaw, Y ;
Meskys, R ;
Malinauskas, A ;
Gorton, L .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 79 (01) :33-38
[7]   Lactate biosensor based on the adsorption of polyelectrolyte stabilized lactate oxidase into porous conductive carbon [J].
Gavalas, VG ;
Chaniotakis, NA .
MIKROCHIMICA ACTA, 2001, 136 (3-4) :211-215
[8]   Flow-through sol-gel optical biosensor for the colorimetric determination of acetazolamide [J].
Jerónimo, PCA ;
Araújo, AN ;
Conceiçao, M ;
Montenegro, BSM ;
Satinsky, D ;
Solich, P .
ANALYST, 2005, 130 (08) :1190-1197
[9]   Properties and applications of proteins encapsulated within sol-gel derived materials [J].
Jin, W ;
Brennan, JD .
ANALYTICA CHIMICA ACTA, 2002, 461 (01) :1-36
[10]   ROTATING-RING-DISK ENZYME ELECTRODE FOR BIOCATALYSIS KINETIC-STUDIES AND CHARACTERIZATION OF THE IMMOBILIZED ENZYME LAYER [J].
KAMIN, RA ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1980, 52 (08) :1198-1205