Intraocular pressure changes following Descemet's stripping with endothelial keratoplasty

被引:32
作者
Espana, Edgar M. [1 ]
Robertson, Zachary M. [1 ]
Huang, Bo [1 ]
机构
[1] Univ Mississippi, Med Ctr, Dept Ophthalmol, Corneal & External Dis Serv, Jackson, MS 39216 USA
关键词
Glaucoma; IOP; Tonometer; Corneal transplant; POSTERIOR LAMELLAR KERATOPLASTY; PENETRATING KERATOPLASTY; TONO-PEN; CORNEAL THICKNESS; EYES; TONOMETER; GLAUCOMA;
D O I
10.1007/s00417-009-1199-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To evaluate the postoperative changes in intraocular pressure (IOP) following Descemet's stripping with endothelial keratoplasty (DSEK). A retrospective chart review of 45 eyes that underwent DSEK for the treatment of corneal edema induced by aphakic or pseudophakic bullous keratopathy (ABK/PBK) and Fuchs' endothelial dystrophy. A mean baseline IOP was obtained at three different preoperative visits using Tono-PenA (R) XL tonometer. This baseline pressure was compared to IOPs obtained at postoperative months 1, 3, 6 and 12. Intraocular pressure increased from a mean preoperative value of 15.6 +/- 4.2 mmHg to 15.9 +/- 5.8 mmHg in the first postoperative month; 17.0 +/- 5.7 mmHg at 3 months; 18.1 +/- 6.2 mmHg at 6 months and 16.8 +/- 4.7 mmHg at 1 year. These pressure differences were considered statistically significant, p = 0.0074 (repeated measures ANOVA). Eyes diagnosed with ABK/PBK (n = 20) showed a significant rise in IOP only noted after the 3(rd) month that peaked at 6 months, p = 0.0001 (repeated measures ANOVA). A subgroup of patients with a diagnosis of Fuchs' endothelial dystrophy (n = 25), showed no statistically significant changes in IOP at 1 year follow-up; p = 0.9103 (repeated measures ANOVA). In a subgroup of eyes with a diagnosis of glaucoma or ocular hypertension (n = 13), a statistically significant increase in IOP was noted after 1 year of follow-up. Mean IOP raised from a preoperative mean value of 16.0 +/- 3.7 mHg to 19.0 +/- 5.3 mmHg at 1 year; p = 0.0074 (repeated measures ANOVA). DSEK induced statistically significant IOP increases in the early postoperative period with a tendency to higher pressures after the 3(rd) month of follow-up. Patients with a preoperative diagnosis of Fuchs' endothelial dystrophy did not show a statistically significant increase in IOP compared to a baseline mean preoperative value. The difference between statistically significant and clinically significant IOP increase is yet to be established.
引用
收藏
页码:237 / 242
页数:6
相关论文
共 28 条
[1]   Penetrating keratoplasty and glaucoma [J].
Ayyala, RS .
SURVEY OF OPHTHALMOLOGY, 2000, 45 (02) :91-105
[2]   Influence of corneal structure, corneal responsiveness, and other ocular parameters on tonometric measurement of Intraocular pressure [J].
Broman, Aimee Teo ;
Congdon, Nathan G. ;
Bandeen-Roche, Karen ;
Quigley, Harry A. .
JOURNAL OF GLAUCOMA, 2007, 16 (07) :581-588
[3]   Post-penetrating keratoplasty glaucoma [J].
Dada, Tanuj ;
Aggarwal, Anand ;
Minudath, K. B. ;
Vanathi, M. ;
Choudhary, Sunil ;
Gupta, Viney ;
Sihota, Ramanjit ;
Panda, Anita .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2008, 56 (04) :269-277
[4]   Corneal Deturgescence after Descemet Stripping Automated Endothelial Keratoplasty Evaluated by Visante Anterior Segment Optical Coherence Tomography [J].
Di Pascuale, Mario A. ;
Prasher, Pawan ;
Schlecte, Charlie ;
Arey, Mark ;
Bowman, R. Wayne ;
Cavanagh, H. Dwight ;
Mcculley, James P. ;
Mootha, V. Vinod .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (01) :32-37
[5]   CORNEAL THICKNESS AND INTRAOCULAR-PRESSURE [J].
EHLERS, N .
EXPERIMENTAL EYE RESEARCH, 1975, 20 (02) :179-179
[6]  
EHLERS N, 1975, ACTA OPHTHALMOL S, V125, P32
[7]   Descemet-stripping automated endothelial keratoplasty [J].
Gorovoy, Mark S. .
CORNEA, 2006, 25 (08) :886-889
[8]   INTRAOCULAR PRESSURE FOLLOWING PENETRATING KERATOPLASTY [J].
IRVINE, AR ;
KAUFMAN, HE .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1969, 68 (05) :835-&
[9]  
Jurgens I, 1997, OPHTHALMIC SURG LAS, V28, P30
[10]   A surgical technique for posterior lamellar keratoplasty [J].
Melles, GRJ ;
Eggink, FAGJ ;
Lander, F ;
Pels, E ;
Rietveld, FJR ;
Beekhuis, WH ;
Binder, PS .
CORNEA, 1998, 17 (06) :618-626