The radiation safety education and the pain physicians' efforts to reduce radiation exposure

被引:26
作者
Kim, Tae Hee [1 ]
Hong, Seung Wan [1 ]
Woo, Nam Sik [1 ]
Kim, Hae Kyoung [1 ]
Kim, Jae Hun [1 ]
机构
[1] Konkuk Univ, Sch Med, Dept Anesthesiol & Pain Med, 120-1 Neungdong Ro, Seoul 05030, South Korea
关键词
Education; Pain procedure; Radiation exposure; Radiation protection; Radiation safety; Surveys and questionnaires;
D O I
10.3344/kjp.2017.30.2.104
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: C-arm fluoroscopy equipment is important for interventional pain management and can cause radiation injury to physicians and patients. We compared radiation safety education and efforts to reduce the radiation exposure of pain specialists. Methods: A survey of 49 pain specialists was conducted anonymously in 2016. The questionnaire had 16 questions. That questionnaire was about radiation safety knowledge and efforts to reduce exposure. We investigated the correlation between radiation safety education and efforts of radiation protection. We compared the results from 2016 and a published survey from 2011. Results: According to the 2016 survey, all respondents used C-arm fluoroscopy in pain interventions. Nineteen respondents (39%) had received radiation safety education. Physicians had insufficient knowledge about radiation safety. When the radiation safety education group and the non-education group are compared, there was no significant difference in efforts to reduce radiation exposure and radiation safety knowledge. When the 2011 and 2016 surveys were compared, the use of low dose mode (P = 0.000) and pulsed mode had increased significantly (P = 0.001). The number checking for damage to radiation protective garments (P = 0.000) and use of the dosimeter had also increased significantly (P = 0.009). But there was no significant difference in other efforts to reduce radiation exposure. Conclusions: Pain physicians seem to lack knowledge of radiation safety and the number of physicians receiving radiation safety education is low. According to this study, education does not lead to practice. Therefore, pain physicians should receive regular radiation safety education and the education should be mandatory.
引用
收藏
页码:104 / 115
页数:12
相关论文
共 22 条
[1]   A Randomized Controlled Trial about the Levels of Radiation Exposure Depends on the Use of Collimation C-arm Fluoroscopic-guided Medial Branch Block [J].
Baek, Seung Woo ;
Ryu, Jae Sung ;
Jung, Cheol Hee ;
Lee, Joo Han ;
Kwon, Won Kyoung ;
Woo, Nam Sik ;
Kim, Hae Kyoung ;
Kim, Jae Hun .
KOREAN JOURNAL OF PAIN, 2013, 26 (02) :148-153
[2]   Radiation risk management during fluoroscopy for interventional pain medicine physicians [J].
Broadman L.M. ;
Navalgund Y.A. ;
Hawkinberry II D.W. .
Current Pain and Headache Reports, 2004, 8 (1) :49-55
[3]   Radiation Safety Program for the Cardiac Catheterization Laboratory [J].
Chambers, Charles E. ;
Fetterly, Kenneth A. ;
Holzer, Ralf ;
Lin, Pei-Jan Paul ;
Blankenship, James C. ;
Balter, Stephen ;
Laskey, Warren K. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 77 (04) :546-556
[4]   A Study to Compare the Radiation Absorbed Dose of the C-arm Fluoroscopic Modes [J].
Cho, Jae Hun ;
Kim, Jae Yun ;
Kang, Joo Eun ;
Park, Pyong Eun ;
Kim, Jae Hun ;
Lim, Jeong Ae ;
Kim, Hae Kyoung ;
Woo, Nam Sik .
KOREAN JOURNAL OF PAIN, 2011, 24 (04) :199-204
[5]   Medical interventional procedures - reducing the radiation risks [J].
Cousins, C ;
Sharp, C .
CLINICAL RADIOLOGY, 2004, 59 (06) :468-473
[6]  
Doerr W., 2015, Annals of the ICRP, V44, P58, DOI 10.1177/0146645314560686
[7]   Radiation safety in pain medicine [J].
Fishman, SM ;
Smith, H ;
Meleger, A ;
Seibert, JA .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2002, 27 (03) :296-305
[8]   Fluoroscopy-induced chronic radiation skin injury -: A disease perhaps often overloohed [J].
Frazier, Thomas H. ;
Richardson, Jeffrey B. ;
Fabre, Vilma C. ;
Callen, Jeffrey P. .
ARCHIVES OF DERMATOLOGY, 2007, 143 (05) :637-640
[9]   Governmental regulations and radiation exposure [J].
Killewich, Lois A. ;
Singleton, Terrell A. .
JOURNAL OF VASCULAR SURGERY, 2011, 53 :44S-46S
[10]   How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions? [J].
Kim, Ah Na ;
Chang, Young Jae ;
Cheon, Bo Kyung ;
Kim, Jae Hun .
KOREAN JOURNAL OF PAIN, 2014, 27 (02) :145-151