Economic impact of contact force sensing in catheter ablation for atrial fibrillation

被引:2
|
作者
Mansour, Moussa [1 ]
Reddy, Vivek Y. [2 ]
Karst, Edward [3 ]
Heist, Edwin Kevin [1 ]
Packer, Douglas L. [4 ]
Dalal, Nirav [3 ]
Agarwal, Rahul [3 ]
Calkins, Hugh [5 ]
Ruskin, Jeremy N. [1 ]
Mahapatra, Srijoy [6 ]
机构
[1] Massachusetts Gen Hosp, Heart Ctr, 55 Fruit St, Boston, MA 02114 USA
[2] Icahn Sch Med Mt Sinai, Helmsley Electrophysiol Ctr, New York, NY 10029 USA
[3] Abbott, Global Data Sci & Analyt, St Paul, MN USA
[4] Mayo Clin, Div Cardiovasc Dis, Rochester, MN USA
[5] Johns Hopkins Univ Hosp, Dept Med, Div Cardiol, Baltimore, MD 21287 USA
[6] Univ Minnesota, Sch Med, Minneapolis, MN 55455 USA
关键词
atrial fibrillation; contact force; economics; MarketScan (R); radiofrequency ablation; TOCCASTAR; PULMONARY VEIN ISOLATION; PREVALENCE;
D O I
10.1111/jce.14189
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation (TOCCASTAR) clinical trial compared clinical outcomes using a contact force (CF) sensing ablation catheter (TactiCath) with a catheter that lacked CF measurement. This analysis links recorded events in the TOCCASTAR study and a large claims database, IBM MarketScan (R), to determine the economic impact of using CF sensing during atrial fibrillation (AF) ablation. Methods and Results Clinical events including repeat ablation, use of antiarrhythmic drugs, hospitalization, perforation, pericarditis, pneumothorax, pulmonary edema, pulmonary vein stenosis, tamponade, and vascular access complications were adjudicated in the year after ablation. CF was characterized as optimal if greater than or equal to 90% lesion was performed with greater than or equal to 10 g of CF. A probabilistic 1:1 linkage was created for subjects in MarketScan (R) with the same events in the year after ablation, and the cost was evaluated over 10 000 iterations. Of the 279 subjects in TOCCASTAR, 145 were ablated using CF (57% with optimal CF), and 134 were ablated without CF. In the MarketScan (R) cohort, 9811 subjects who underwent AF ablation were used to determine events and costs. For subjects ablated with optimal CF, total cost was $19 271 +/- 3705 in the year after ablation. For ablation lacking CF measurement, cost was $22 673 +/- 3079 (difference of $3402, P < .001). In 73% of simulations, optimal CF was associated with lower cost in the year after ablation. Conclusion Compared to ablation without CF, there was a decrease in healthcare cost of $3402 per subject in the first year after the procedure when optimal CF was used.
引用
收藏
页码:2302 / 2309
页数:8
相关论文
共 50 条
  • [41] Effect of respiration on catheter-tissue contact force during ablation of atrial arrhythmias
    Kumar, Saurabh
    Morton, Joseph B.
    Halloran, Karen
    Spence, Steven J.
    Lee, Geoffrey
    Wong, Michael C. G.
    Kistler, Peter M.
    Kalman, Jonathan M.
    HEART RHYTHM, 2012, 9 (07) : 1041 - +
  • [42] Frontier of catheter ablation for atrial fibrillation
    Iesaka, Yoshito
    JOURNAL OF CARDIOLOGY, 2011, 58 (02) : 99 - 107
  • [43] Catheter Ablation of Lone Atrial Fibrillation
    Mujovic, Nebojsa M.
    Marinkovic, Milan M.
    Potpara, Tatjana S.
    Geller, Laszlo
    CURRENT PHARMACEUTICAL DESIGN, 2015, 21 (05) : 591 - 612
  • [44] Impact of pulmonary veins anatomy on the outcomes of radiofrequency ablation for paroxysmal atrial fibrillation in the era of contact force-sensing ablation catheters
    Benali, Karim
    Lai, Van Duc
    Hammache, Nefissa
    Magnin-Poull, Isabelle
    de Chillou, Christian
    Sellal, Jean-Marc
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (04) : 931 - 940
  • [45] Catheter ablation of atrial fibrillation: an update
    Haegeli, Laurent M.
    Calkins, Hugh
    EUROPEAN HEART JOURNAL, 2014, 35 (36) : 2454 - +
  • [46] Impact of pulmonary veins anatomy on the outcomes of radiofrequency ablation for paroxysmal atrial fibrillation in the era of contact force-sensing ablation catheters
    Karim Benali
    Van Duc Lai
    Nefissa Hammache
    Isabelle Magnin-Poull
    Christian de Chillou
    Jean-Marc Sellal
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 931 - 940
  • [47] Feasibility and safety of high-power ablation of atrial fibrillation with contact force-sensing catheter: The lesion size index-guided ablation
    Parwani, Abdul Shokor
    Hohendanner, Felix
    Kluck, Amelie
    Blaschke, Florian
    Pieske, Burkert
    Boldt, Leif-Hendrik
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2022, 31 (07): : 715 - 721
  • [48] Predictors of recurrent atrial fibrillation following catheter ablation
    Mohanty, Sanghamitra
    Della Rocca, Domenico G.
    Gianni, Carola
    Trivedi, Chintan
    Mayedo, Angel Quintero
    MacDonald, Bryan
    Natale, Andrea
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2021, 19 (03) : 237 - 246
  • [49] The impact of catheter ablation for atrial fibrillation in heart failure
    Moschonas, Konstantinos
    Nabeebaccus, Adam
    Okonko, Darlington O.
    McDonagh, Theresa A.
    Murgatroyd, Francis D.
    Dhillon, Para
    Scott, Paul A.
    JOURNAL OF ARRHYTHMIA, 2019, 35 (01) : 33 - 42
  • [50] Hybrid atrial fibrillation ablation in patients with persistent atrial fibrillation or failed catheter ablation
    Al-Jazairi, M. I. H.
    Rienstra, M.
    Klinkenberg, T. J.
    Mariani, M. A.
    van Gelder, I. C.
    Blaauw, Y.
    NETHERLANDS HEART JOURNAL, 2019, 27 (03) : 142 - 151