Safety of a thermal vessel sealer on main pulmonary vessels

被引:26
作者
Lacin, Tunc
Batirel, Hasan Fevzi
Ozer, Kursat
Demirutku, Alper
Ahiskali, Rengin
Yuksel, Mustafa
机构
[1] Marmara Univ Hosp, Dept Thorac Surg, Istanbul, Turkey
[2] Istanbul Univ, Fac Vet Med, Istanbul, Turkey
[3] Marmara Univ, Fac Med, Dept Pathol, Istanbul, Turkey
关键词
pulmonary artery; pulmonary vein; LigaSure; vascular division;
D O I
10.1016/j.ejcts.2006.11.038
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: LigaSure (Valleylab, Tyco Healthcare, Boulder, CO)is a novel instrument with widespread use in various surgical disciplines for vessel seating. It uses heat energy to denature collagen and elastin and achieve vessel seating. We investigated the safety of LigaSure in pulmonary arteries (PA) and veins (PV). Methods: Twelve sheep were anesthetized and endotracheally intubated. Six underwent right lower lobectomy (Group 1) and six right upper lobectomy (Group 2). All of the vessels in both groups were divided with LigaSure. Diameters of vessels were measured. Intraoperatively, pulmonary artery pressures (PAP) were monitored in Group 1. Following vascular division, ephedrine was injected to increase PAP in Group 1. In Group 2, animals were followed and euthanized at 7 days. Both immediate and 7 day samples were obtained from divided vessel stumps. Conventional histology was done. Statistical analysis was performed using t-test and Fisher's exact test. Results: Mean diameter of PAs (n = 9) divided in Group 1 was 8.3 mm (3-11) and of PVs (n = 8) was 10.4 mm (4-15). Mean PAP increased from 18 (27/9) to 27 (45/18) mmHg after ephedrine injection. Dehiscence rate was 2/6 in PAs and 3/6 in PVs larger than 9 mm in diameter. Mean diameter of PAs (n = 8) divided in Group 2 was 5.7 mm (3-7) and of PVs (n = 9) was 4.6 mm (4-6). No early or late (7 days) vascular disruption was seen in Group 2. Bleeding incidence was significantly different between groups (Fisher's exact test p = 0.015). Overall no dehiscence was observed in vessels less than 7 mm in diameter. Histology of intraoperative samples showed thermal injury and necrosis. Seven day samples showed short segment necrosis limited to the vessel watt, fibrosis, thrombus formation without inflammation, and minimal granulation tissue. Conclusions: LigaSure achieves perfect seating in pulmonary vessels less than 7 mm in diameter in sheep intra- and postoperatively even following a pressure challenge. It can safety be used in segmental branches of PAs and PVs during open or thoracoscopic surgery. (c) 2007 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:482 / 485
页数:4
相关论文
共 17 条
[1]   Thoracoscopic lobectomy for prenatally diagnosed lung lesions [J].
Albanese, CT ;
Sydorak, RM ;
Tsao, K ;
Lee, HM .
JOURNAL OF PEDIATRIC SURGERY, 2003, 38 (04) :553-555
[2]   A comparison of laparoscopic bipolar vessel sealing devices in the hemostasis of small-, medium-, and large-sized arteries [J].
Carbonell, AM ;
Joels, CS ;
Kercher, KW ;
Matthews, BD ;
Sing, RF ;
Heniford, BT .
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES-PART A, 2003, 13 (06) :377-380
[3]   Use of the LigaSure vessel sealing device in laparoscopic living-donor nephrectomy [J].
Constant, DL ;
Florman, SS ;
Mendez, F ;
Thomas, R ;
Slakey, DP .
TRANSPLANTATION, 2004, 78 (11) :1661-1664
[4]   Sutureless and stapleless laparoscopic splenectomy using radiofrequency - LigaSure device [J].
Gelmini, R. ;
Romano, F. ;
Quaranta, N. ;
Caprotti, R. ;
Tazzioli, G. ;
Colombo, G. ;
Saviano, M. ;
Uggeri, F. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (06) :991-994
[5]   Comparison of thermal spread after ureteral ligation with the Laparo-sonic™ ultrasonic shears and the Ligasure™ system [J].
Goldstein, SL ;
Harold, KL ;
Lentzner, A ;
Matthews, BD ;
Kercher, KW ;
Sing, RF ;
Pratt, B ;
Lipford, EH ;
Heniford, BT .
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES-PART A, 2002, 12 (01) :61-63
[6]   Randomized clinical trial of Ligasure™ versus conventional surgery for extended gastric cancer resection [J].
Lee, WJ ;
Chen, TC ;
Lai, IR ;
Wang, W ;
Huang, MT .
BRITISH JOURNAL OF SURGERY, 2003, 90 (12) :1493-1496
[7]   Vascular pedicle ligation techniques during laparoscopic colectomy - A prospective randomized trial [J].
Marcello, PW ;
Roberts, PL ;
Rusin, LC ;
Holubkov, R ;
Schoetz, DJ .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (02) :263-269
[8]  
Matthews BD, 2001, AM SURGEON, V67, P901
[9]   Hepatic surgery using the ligasure vessel sealing system [J].
Romano, F ;
Franciosi, C ;
Caprotti, R ;
Uggeri, F ;
Uggeri, F .
WORLD JOURNAL OF SURGERY, 2005, 29 (01) :110-112
[10]   Usefulness of LigaSure for liver resection: analysis by randomized clinical trial [J].
Saiura, Akio ;
Yamamoto, Junji ;
Koga, Rintaro ;
Sakamoto, Yoshihiro ;
Kokudo, Norihiro ;
Seki, Makoto ;
Yamaguchi, Takuhiro ;
Yamaguchi, Toshiharu ;
Muto, Tetsuichiro ;
Makuuchi, Masatoshi .
AMERICAN JOURNAL OF SURGERY, 2006, 192 (01) :41-45