Effects of a pneumatic tube system on the hemolysis of blood samples: a PRISMA-compliant meta-analysis

被引:6
作者
Ding, Xuemei [1 ,2 ]
Wen, Xiulin [1 ]
Wang, Liying [3 ]
Chen, Ting [3 ]
Zhou, Guangxia [4 ]
He, Hairong [5 ]
Xin, Xia [1 ]
机构
[1] Xi An Jiao Tong Univ, Nursing Dept, Affiliated Hosp 1, 277 Yanta West Rd, Xian 710061, Peoples R China
[2] Binzhou Med Coll, Dept Nursing, Yantai, Peoples R China
[3] Yanan Univ, Dept Nursing, Med Coll, Yanan, Peoples R China
[4] Xian Fourth Hosp, Nursing Dept, Xian, Shanxi, Peoples R China
[5] Xi An Jiao Tong Univ, Clin Res Ctr, Affiliated Hosp 1, Xian, Peoples R China
关键词
Specimen handling; blood chemical analysis; pre-analytical phase; quality control; transportation; hemolysis; meta-analysis; DELIVERY-SYSTEM; TRANSPORT; PARAMETERS;
D O I
10.1080/00365513.2021.1930140
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Many studies have explored how using a pneumatic tube system (PTS) is related to the hemolysis of blood samples, but their conclusions have been inconsistent. This meta-analysis was to clarify whether using a PTS induces the hemolysis of blood samples. The PubMed, Embase, Scopus, CNKI, CqVip, SinoMed and WanFang databases were searched for studies published between January 1970 and August 2019. The primary outcomes were the hemolysis rate and hemolysis index of blood samples after applying a PTS and manual transportation. We estimated the pooled risk ratio (RR) and the standardized mean difference (SMD), using random-effects models. This meta-analysis included 29 studies covering 3121 blood samples. No significant differences were found between the PTS and manual-transportation groups in the hemolysis rate [RR: 0.99, 95% confidence interval (CI): 0.57 to 1.70], hemolysis index (SMD: 0.19, 95% CI: -0.00 to 0.38), or level of potassium (SMD: 0.05, 95% CI: -0.03 to 0.12), alanine aminotransferase (SMD: 0.00, 95% CI: -0.10 to 0.11), or aspartate aminotransferase (SMD: 0.04, 95% CI: -0.08 to 0.17). However, lactate dehydrogenase (LDH) level was significantly higher in the PTS group than in the manual-transportation group (SMD: 0.20, 95% CI: 0.06 to 0.34). Subgroup analysis revealed that the LDH level was clearly higher in the PTS group than in the manual-transportation group only when the PTS speed was >= 6 m/s or when the PTS distance was >= 250 m. According to this meta-analysis, PTSs were associated with alterations in LDH measurements, so it is sensible that each hospital validates and monitors their PTSs.
引用
收藏
页码:343 / 352
页数:10
相关论文
共 37 条
  • [1] Andersen IB, 2017, J APPL LAB MED, V1, P376, DOI 10.1373/jalm.2016.021188
  • [2] [Anonymous], 1977, LAB MED
  • [3] [Anonymous], 2015, NED TIJDSCHR KLIN CH
  • [4] THE EFFECT OF PNEUMATIC TUBE SYSTEMS ON THE HEMOLYSIS OF BIOCHEMISTRY BLOOD SAMPLES
    Cakirca, Gokhan
    Erdal, Huseyin
    [J]. JOURNAL OF EMERGENCY NURSING, 2017, 43 (03) : 255 - 258
  • [5] Changes of Serum Lactate Dehydrogenase and Potassium Levels Produced by a Pneumatic Tube System
    Cui, Ming
    Jing, Rongrong
    Wang, Haimin
    [J]. LABMEDICINE, 2009, 40 (12): : 728 - 731
  • [6] Effect of Pneumatic Tube Delivery System Rate and Distance on Hemolysis of Blood Specimens
    Evliyaoglu, Osman
    Toprak, Gulten
    Tekin, Alicem
    Basarali, Mustafa Kemal
    Kilinc, Cumhur
    Colpan, Leyla
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2012, 26 (02) : 66 - 69
  • [7] Pneumatic tube delivery system for blood samples reduces turnaround times without affecting sample quality
    Fernandes, CMB
    Worster, A
    Eva, K
    Hill, S
    McCallum, C
    [J]. JOURNAL OF EMERGENCY NURSING, 2006, 32 (02) : 139 - 143
  • [8] Smartphone Application Monitoring of Acceleration Forces During Pneumatic Tube System Transport of Emergency Department Patient Samples
    Heireman, Laura
    Stroobants, Jan
    Uyttenbroeck, Wim
    Goossens, Yvonne
    Dreezen, Christa
    Luyts, Dave
    Van Den Broeck, Lutgarde
    Delanghe, Joris
    Heylen, Evelien
    Mahieu, Boris
    [J]. CLINICAL LABORATORY, 2018, 64 (7-8) : 1297 - 1304
  • [9] Higgins Julian PT, 2019, COCHRANE HDB SYSTEMA, V1, DOI [DOI 10.1002/9781119536604, 10.1002/9781119536604]
  • [10] Kapoula G, 2015, SCI CHRON, V20, P194