Needle-free connectors catheter-related bloodstream infections: a prospective randomized controlled trial

被引:12
作者
Koeppen, Michael [1 ]
Weinert, Franziska [2 ]
Oehlschlaeger, Sabrina [3 ]
Koerner, Andreas [1 ]
Rosenberger, Peter [1 ]
Haeberle, Helene Anna [1 ]
机构
[1] Univ Klinikum Tubingen, Dept Anesthesiol & Intens Care Med, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
[2] Klinikum Sindelfingen Boblingen, Dept Anesthesiol, Boblingen, Germany
[3] Univ Hosp, Dept Cardiac Surg, Tubingen, Germany
关键词
Needle-free connectors; Catheter-related bloodstream infections; Bionecteur (R); INCREASE;
D O I
10.1186/s40635-019-0277-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background In the critically ill, catheter-related bloodstream infection can result from bacterial contamination of infusion hubs of intravascular catheters. Needle-free connectors (NFC) have been suggested to reduce the rate of bacterial contamination and subsequent catheter-related bloodstream infection (CRBSI), but data remains ambiguous. Thus, we tested if a novel NFC would reduce bacterial contamination and subsequent CRBSI. Results In a prospective, randomized controlled trial, surgical ICU patients were randomized to three-way hubs closed by caps or Bionecteur (R) (Vygon, Inc.) of central venous catheters. Every 72 h, infusion lines were renewed and microbiological samples were taken. Bacterial growth was analyzed by blinded microbiologists. Incidence of bacterial contamination and CRSBI were assessed. Outcome parameters like length of stay on ICU and outcome were retrospectively assessed. Two thousand seven hundred patients were screened, 111 were randomized to the NFC, and 109 into the control group. Finally, 24 patients in the NFC and 23 control patients were analyzed. The majority of samples (NFC 77%; control 70%) found no bacterial growth. Coagulase-negative staphylococci were most commonly detected on CVC samples (NFC 17%; control 21%). We found CRBSI (defined as identical pathogens in blood culture and catheter line tip culture, and clinical manifestations of infection) in two control patients and one patient of the NFC group. Their length of ICU stay did not differ between groups (NFC 19 days; control 23 days). Conclusion The use of NFC does not influence the rate of bacterial contamination of infusion hubs of central venous catheters.
引用
收藏
页数:11
相关论文
共 21 条
  • [1] A prospective clinical trial to evaluate the microbial barrier of a needleless connector
    Casey, A. L.
    Burnell, S.
    Whinn, H.
    Worthington, T.
    Faroqui, M. H.
    Elliott, T. S. J.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2007, 65 (03) : 212 - 218
  • [2] Casey Anna L, 2018, Br J Nurs, V27, pS18, DOI 10.12968/bjon.2018.27.2.S18
  • [3] Nurse staffing, burnout, and health care-associated infection
    Cimiotti, Jeannie P.
    Aiken, Linda H.
    Sloane, Douglas M.
    Wu, Evan S.
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2012, 40 (06) : 486 - 490
  • [4] Leaving More Than Your Fingerprint on the Intravenous Line: A Prospective Study on Propofol Anesthesia and Implications of Stopcock Contamination
    Cole, Devon C.
    Baslanti, Tezcan Ozrazgat
    Gravenstein, Nikolaus L.
    Gravenstein, Nikolaus
    [J]. ANESTHESIA AND ANALGESIA, 2015, 120 (04) : 861 - 867
  • [5] BLOOD-STREAM INFECTIONS ASSOCIATED WITH A NEEDLELESS INTRAVENOUS-INFUSION SYSTEM IN PATIENTS RECEIVING HOME INFUSION THERAPY
    DANZIG, LE
    SHORT, LJ
    COLLINS, K
    MAHONEY, W
    SEPE, S
    BLAND, L
    JARVIS, WR
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 273 (23): : 1862 - 1864
  • [6] Bloodstream infection related to catheter connections: a prospective trial of two connection systems
    Esteve, F.
    Pujol, M.
    Limon, E.
    Saballs, M.
    Argerich, M. J.
    Verdaguer, R.
    Manez, R.
    Ariza, X.
    Gudiol, F.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2007, 67 (01) : 30 - 34
  • [7] A survey in Mexico about ethics dumping in clinical research
    German, Novoa-Heckel
    Rosemarie, Bernabe
    [J]. BMC MEDICAL ETHICS, 2019, 20 (1)
  • [8] Universal Intravenous Access Cleaning Device Fails to Sterilize Stopcocks
    Holroyd, Julie L.
    Paulus, David A.
    Rand, Kenneth H.
    Enneking, F. Kayser
    Morey, Timothy E.
    Rice, Mark J.
    [J]. ANESTHESIA AND ANALGESIA, 2014, 118 (02) : 333 - 343
  • [9] Biocidal Agents Used for Disinfection Can Enhance Antibiotic Resistance in Gram-Negative Species
    Kampf, Guenter
    [J]. ANTIBIOTICS-BASEL, 2018, 7 (04):
  • [10] Lutz P, 2018, INTENSIVMEDUP2DATE, V14, P167