Biosensor based on an oxygen reducing bilirubin oxidase electrode

被引:4
作者
Goebel, G. [1 ]
Dietz, T. [1 ]
Lisdat, F. [1 ]
机构
[1] Univ Appl Sci Wildau, D-15745 Wildau, Germany
来源
PROCEEDINGS OF THE EUROSENSORS XXIII CONFERENCE | 2009年 / 1卷 / 01期
关键词
enzyme sensor; bilirubin oxidase; carbon nanotubes; membran-free; mediator-less; CARBON ELECTRODES; REDUCTION; DIOXYGEN;
D O I
10.1016/j.proche.2009.07.068
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An oxygen reducing electrode made of bilirubin oxidase and multi-walled carbon nanotubes (BOD-MWCNT-Au electrode) is coupled to enzymes catalysing oxygen-consuming reactions such as glucose oxidase (GOD) to result in a membrane-free bienzyme electrode. The feasibility of such a molecularly assembled system stabilized by covalent linkage has been demonstrated. The electrochemical characterisation of the bienzyme electrode reveals sensitivity to the enzyme substrate. The results indicate that the BOD-electrode provides a suitable platform for sensing analytes for which oxidases of high activity are available.
引用
收藏
页码:273 / 276
页数:4
相关论文
共 50 条
[41]   Theoretical Modeling, Facile Fabrication, and Experimental Study of Optimally Bound Bilirubin Oxidase on Palladium Nanoparticles for Enhanced Oxygen Reduction Reaction [J].
Poon, Kee Chun ;
Ma, Xiaohua ;
Tan, Desmond C. L. ;
Su, Haibin ;
Sato, Hirotaka .
ACS CATALYSIS, 2018, 8 (06) :4950-+
[42]   Electrocatalytic reduction of oxygen by bilirubin oxidase in hydrophobic ionic liquids containing a small quantity of water [J].
Kuwahara, Jun ;
Ikari, Ryunosuke ;
Murata, Kenichi ;
Nakamura, Nobuhumi ;
Ohno, Hiroyuki .
CATALYSIS TODAY, 2013, 200 :49-53
[43]   Binder/surfactant-free biocathode with bilirubin oxidase for gas-diffusion-type system [J].
So, Keisei ;
Onizuka, Maki ;
Komukai, Takuji ;
Kitazumi, Yuki ;
Shirai, Osamu ;
Kano, Kenji .
ELECTROCHEMISTRY COMMUNICATIONS, 2016, 66 :58-61
[44]   Poly(lactic acid)-based Nanocomposite for Construction of Efficient Bilirubin Oxidase-Based Biocathodes and Stable Biofuel Cells [J].
Filip, Jaroslav ;
Monosik, Rastislav ;
Tkac, Jan .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (05) :2491-2506
[45]   An Formaldehyde Biosensor Based on Carbon Nanotubes Modified Electrode [J].
Zhang Ren-Yan ;
Zhang Xue-Ao ;
Jia Hong-Hui ;
Li Xin-Hua .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (06) :909-914
[46]   Amperometric catechol biosensor based on polyaniline-polyphenol oxidase [J].
Tan, Yongyan ;
Guo, Xiaoxia ;
Zhang, Jinghui ;
Kan, Jinqing .
BIOSENSORS & BIOELECTRONICS, 2010, 25 (07) :1681-1687
[47]   Amperometric glucose biosensor based on silver nanowires and glucose oxidase [J].
Wang, Lisha ;
Gao, Xia ;
Jin, Lingyan ;
Wu, Qi ;
Chen, Zhichun ;
Lin, Xianfu .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 :9-14
[48]   An electrochemical biosensor with cholesterol oxidase/sol-gel film on a nanoplatinum/carbon nanotube electrode [J].
Shi, QC ;
Peng, TZ ;
Zhu, YN ;
Yang, CF .
ELECTROANALYSIS, 2005, 17 (10) :857-861
[49]   Construction of a bilirubin biosensor based on an albumin-immobilized quartz crystal microbalance [J].
Kocakulak, Mustafa ;
Bayrak, Tuncay ;
Saglam, Sinan .
BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2017, 37 (03) :611-617
[50]   Bilirubin Oxidase-Based Nanobiocathode Working in Serum-Mimic Buffer for Implantable Biofuel Cell [J].
Gutierrez-Sanchez, Cristina ;
Pita, Marcos ;
Toscano, Miguel D. ;
De Lacey, Antonio L. .
ELECTROANALYSIS, 2013, 25 (06) :1359-1362