Study on the effects of runner geometric parameters on the performance of micro Francis turbines used in water supply system of high-rise buildings

被引:12
作者
Du, Jiyun [1 ]
Ge, Zhan [1 ]
Wu, Hao [1 ]
Shi, Xudong [1 ]
Yuan, Fangyang [1 ]
Yu, Wei [1 ]
Wang, Dongxiang [1 ]
Yang, Xinjun [1 ]
机构
[1] Jiangnan Univ, Sch Mech Engn, Jiangsu Key Lab Adv Food Mfg Equipment & Technol, Wuxi 214122, Jiangsu, Peoples R China
关键词
Francis turbine; Energy harvesting; Water supply system; High-rise buildings; POWER-GENERATION; BLADE; EFFICIENCY; DESIGN; ENERGY; METHODOLOGY; NETWORKS;
D O I
10.1016/j.energy.2022.124616
中图分类号
O414.1 [热力学];
学科分类号
摘要
With the increasing emphasis on clean energy, there is growing attention to the use of microturbines or pumps as turbines (PATs) to recover excess hydraulic energy in the water supply system (WSS) of high-rise buildings. In this paper, a micro Francis turbine for WSS in high-rise buildings was presented, and the effects of runner geometric parameters on turbine performance were investigated through computa-tional fluid dynamics (CFD) and lab tests. In the research process, based on the theoretical design results and the numerical optimization of blade exit angle and blade shape, a turbine model was obtained for laboratory testing. The test results show that the Francis turbine has a relatively good performance in both energy generation and water head reduction. In addition, the feasibility of the used runner design method was verified in this special working condition by comparing the experimental performance of turbines with different runner inlet widths. Based on a numerical model that has been validated by experimental results, further optimization for blade thickness and blade number was carried out through CFD simulations. The simulation results show that blade thickness and blade number can affect energy consumption and pressure distribution in the runner and thus affect turbine performance, and there are optimal values to achieve optimal turbine performance. And the optimized model had an output power of 148 W and an efficiency of 21.23% at the design condition.(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页数:14
相关论文
共 35 条
[1]   CFD based design of a 4.3MW Francis turbine for improved performance at design and off-design conditions [J].
Aradag, Selin ;
Akin, Hasan ;
Celebioglu, Kutay .
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2017, 31 (10) :5041-5049
[2]   PAT Design Strategy for Energy Recovery in Water Distribution Networks by Electrical Regulation [J].
Carravetta, Armando ;
del Giudice, Giuseppe ;
Fecarotta, Oreste ;
Ramos, Helena M. .
ENERGIES, 2013, 6 (01) :411-424
[3]   A novel vertical axis water turbine for power generation from water pipelines [J].
Chen, J. ;
Yang, H. X. ;
Liu, C. P. ;
Lau, C. H. ;
Lo, M. .
ENERGY, 2013, 54 :184-193
[4]   Energy efficiency of elevated water supply tanks for high-rise buildings [J].
Cheung, C. T. ;
Mui, K. W. ;
Wong, L. T. .
APPLIED ENERGY, 2013, 103 :685-691
[5]   Efficiency achievement in water supply systems-A review [J].
Coelho, B. ;
Andrade-Campos, A. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 30 :59-84
[6]   Development of an inline vertical cross-flow turbine for hydropower harvesting in urban water supply pipes [J].
Du Jiyun ;
Yang Hongxing ;
Shen Zhicheng ;
Guo Xiaodong .
RENEWABLE ENERGY, 2018, 127 :386-397
[7]   Micro hydro power generation from water supply system in high rise buildings using pump as turbines [J].
Du, Jiyun ;
Yang, Hongxing ;
Shen, Zhicheng ;
Chen, Jian .
ENERGY, 2017, 137 :431-440
[8]   Operation, performance and economic analysis of low head micro-hydropower turbines for rural and remote areas: A review [J].
Elbatran, A. H. ;
Yaakob, O. B. ;
Ahmed, Yasser M. ;
Shabara, H. M. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 43 :40-50
[9]  
Feng J, 2017, ADV MECH ENG, V9
[10]  
Guan X, 2011, Modern pumps theory and design