Biomechanics of reverse total shoulder arthroplasty

被引:133
作者
Berliner, Jonathan L. [1 ]
Regalado-Magdos, Ashton [1 ]
Ma, C. Benjamin [1 ]
Feeley, Brian T. [1 ]
机构
[1] Univ Calif San Francisco, Dept Orthopaed Surg, San Francisco, CA 94143 USA
关键词
Reverse total shoulder arthroplasty; biomechanics; implant design; surgical technique; scapular notching; instability; functional outcomes; HUMERAL COMPONENT RETROVERSION; GLENOID COMPONENT; GLENOHUMERAL JOINT; MOMENT ARMS; CUFF TEAR; PROSTHESIS; MOTION; STABILITY; FIXATION; MUSCLE;
D O I
10.1016/j.jse.2014.08.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Reverse total shoulder arthroplasty is an effective procedure for treatment of glenohumeral joint disease among patients with severe rotator cuff deficiency. Improvements in prosthetic design are the result of an evolved understanding of both shoulder and joint replacement biomechanics. Although modern generations of the reverse shoulder prosthesis vary in specific design details, they continue to adhere to Grammont's core principles demonstrated by his original Delta III prosthesis. This review article discusses the biomechanics of reverse total shoulder arthroplasty with a focus on elements of implant design and surgical technique that may affect stability, postoperative complications, and functional outcomes. (C) 2015 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:150 / 160
页数:11
相关论文
共 85 条
[1]   Axial Rotation Moment Arms of the Shoulder Musculature After Reverse Total Shoulder Arthroplasty [J].
Ackland, David C. ;
Richardson, Martin ;
Pandy, Marcus G. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (20) :1886-1895
[2]   Muscle and Joint-Contact Loading at the Glenohumeral Joint after Reverse Total Shoulder Arthroplasty [J].
Ackland, David C. ;
Roshan-Zamir, Sasha ;
Richardson, Martin ;
Pandy, Marcus G. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (12) :1850-1858
[3]   Moment Arms of the Shoulder Musculature After Reverse Total Shoulder Arthroplasty [J].
Ackland, David C. ;
Roshan-Zamir, Sasha ;
Richardson, Martin ;
Pandy, Marcus G. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (05) :1221-1230
[4]   Contribution of the reverse endoprosthesis to glenohumeral kinematics [J].
Bergmann, Jeroen H. M. ;
de Leeuw, M. ;
Janssen, Thomas W. J. ;
Veeger, DirkJan H. E. J. ;
Willems, W. J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (03) :594-598
[5]   Evaluation of the role of glenosphere design and humeral component retroversion in avoiding scapular notching during reverse shoulder arthroplasty [J].
Berhouet, Julien ;
Garaud, Pascal ;
Favard, Luc .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (02) :151-158
[6]   OPERATIVE TREATMENT OF FAILED REPAIRS OF THE ROTATOR CUFF [J].
BIGLIANI, LU ;
CORDASCO, FA ;
MCILVEEN, SJ ;
MUSSO, ES .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (10) :1505-1515
[7]   Grammont reverse prosthesis: Design, rationale, and biomechanics [J].
Boileau, P ;
Watkinson, DJ ;
Hatzidakis, AM ;
Balg, F .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (01) :147S-161S
[8]   Neer Award 2005: The Grammont reverse shoulder prosthesis: Results in cuff tear arthritis, fracture sequelae, and revision arthroplasty [J].
Boileau, Pascal ;
Watkinson, Duncan ;
Hatzidakis, Armodios M. ;
Hovorka, Istvan .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (05) :527-540
[9]   Bony Increased-offset Reversed Shoulder Arthroplasty: Minimizing Scapular Impingement While Maximizing Glenoid Fixation [J].
Boileau, Pascal ;
Moineau, Gregory ;
Roussanne, Yannick ;
O'Shea, Kieran .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (09) :2558-2567
[10]   Reverse total shoulder arthroplasty after failed rotator cuff surgery [J].
Boileau, Pascal ;
Gonzalez, Jean-Francois ;
Chuinard, Christopher ;
Bicknell, Ryan ;
Walch, Gilles .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (04) :600-606