Performance improvement of a power conversion module by liquid micro-jet impingement cooling

被引:51
作者
Bhunia, Avijit [1 ]
Chandrasekaran, Sriram
Chen, Chung-Lung
机构
[1] Teledyne Sci Co, Thousand Oaks, CA 91360 USA
[2] ColdWatt Inc, Austin, TX 78750 USA
来源
IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES | 2007年 / 30卷 / 02期
关键词
closed loop; impingement cooling; insulated gate bipolar transistor (IGBT) module; inverter; liquid micro-jet; motor drive;
D O I
10.1109/TCAPT.2007.898366
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Liquid micro-jet array impingement cooling of a power conversion module with 12 power switching devices (six insulated gate bipolar transistors and six diodes) is investigated. The 1200-V/150-A module converts dc input power to variable frequency, variable voltage three-phase ac output to drive a 50 HP three-phase induction motor. The silicon devices are attached to a packaging layer [direct bonded copper (DBC)], which in turn is soldered to a metal base plate. DI water micro-jet array impinges on the base plate of the module targeted at the footprint area of the devices. Although the high heat flux cooling capability of liquid impingement is a well-established finding, the impact of its practical implementation in power systems has never been addressed. This paper presents the first one-to-one comparison of liquid micro-jet array impingement cooling (JAIC) with the traditional methods, such as air-cooling over finned heat sink or liquid flow in multi-pass cold plate. Results show that compared to the conventional cooling methods, JAIC can significantly enhance the module output power. If the output power is maintained constant, the device temperature can be reduced drastically by JAIC. Furthermore, jet impingement provides uniform cooling for multiple devices placed over a large area, thereby reducing non-uniformity of temperature among the devices. The reduction in device temperature, both its absolute value and the non-uniformity, implies multi-fold increase in module reliability. The results thus illustrate the importance of efficient thermal management technique for compact and reliable power conversion application.
引用
收藏
页码:309 / 316
页数:8
相关论文
共 15 条
[1]  
*AAVID THERM INC, 2007, LIQ COOL COLD PLAT
[2]  
Bhimia A., 2003, P 41 AIAA AER SCI M
[3]  
Copeland D., 1998, International Journal of Microelectronic Packaging, Materials and Technologies, V1, P105
[4]  
*EBMP INC, 2007, MOT IMP
[5]  
FABBRI M, 2003, P ASME SUMM HEAT TRA
[6]  
*INF TECHN AG, 2007, EUPEC BSM100GD120DN2
[7]  
JIJI LJ, 1987, P INT S COOL TECHN E, P333
[8]  
LIENHARD JH, 1995, ANN REV HEAT TRANSFE, V6, P199, DOI DOI 10.1615/ANNUALREVHEATTRANSFER.V6.60]
[9]  
Mitic G, 2002, THERMAL CHALLENGES IN NEXT GENERATION ELECTRONIC SYSTEMS, P147
[10]   DESCRIBING THE UNCERTAINTIES IN EXPERIMENTAL RESULTS [J].
MOFFAT, RJ .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1988, 1 (01) :3-17