Background. In. the assessment of fluid status after cardiac surgery, we applied bioelectrical impedance analysis (BIA) to measure the total body water (TBW), extracellular fluid (ECF), and intracellular fluid (ICF), and evaluated its validity. Methods. Thirty patients who underwent cardiopulmonary bypass (CPB group) and 19 surgical patients not receiving CPB (non-CPB group). Results. The change of BIA values (Delta TBW, Delta ECF, Delta ICF), body weight and cumulative fluid balance were determined for 120 postoperative hours, and the relationship between BIA values and body weight and fluid balance were evaluated. Postoperative changes in BIA values in the CPB group were compared with those in the non-CPB group. Finally the ECF/ICF ratio and hemodynamic parameters were compared. Delta TBW and Delta ECF correlated with changes in body weight and fluid balance, respectively. Especially there was a high correlation in each case although large deviations in the slope of the regression lines were observed TBW and ECF increased from immediately after operation up to 96 hours (the maximum value was at day 2). On the other hand, ICF decreased from 48 to 72 hours after operation. There were significant high ECF/ICF in the CPB group compared with the non-CPB group from 12 to 72 postoperative hours. We found that ECF/ICF correlated inversely with mean blood pressure, mixed venous oxygen saturation and colloid osmotic pressure, acid positively with central venous pressure and pulmonary artery wedge pressure. Conclusions. It was considered that BIA was useful for evaluating the relative changes in TBW and fluid distribution, and ECF/ICF might be a new parameter for abnormal water metabolism after cardiac surgery.
引用
收藏
页码:559 / 566
页数:8
相关论文
共 50 条
  • [1] Bedside determination of fluid accumulation after cardiac surgery using segmental bioelectrical impedance
    Bracco, D
    Revelly, JP
    Berger, MM
    Chioléro, RL
    CRITICAL CARE MEDICINE, 1998, 26 (06) : 1065 - 1070
  • [2] Evaluation of bioelectrical impedance analysis as an estimator of moose body composition
    Hundertmark, KJ
    Schwartz, CC
    WILDLIFE SOCIETY BULLETIN, 2002, 30 (03) : 915 - 921
  • [3] Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
    Castillo-Martinez, Lilia
    Bernal-Ceballos, Fernanda
    Reyes-Paz, Yunuen
    Hernandez-Gilsoul, Thierry
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (186):
  • [4] Bioelectrical impedance analysis for assessment of fluid status and body composition in neonates—the good, the bad and the unknown
    B E Lingwood
    European Journal of Clinical Nutrition, 2013, 67 : S28 - S33
  • [5] Body fluid overload and bioelectrical impedance analysis in renal patients
    Piccoli, A
    Rossi, B
    Pillon, L
    Bucciante, G
    MINERAL AND ELECTROLYTE METABOLISM, 1996, 22 (1-3) : 76 - 78
  • [6] Bioelectrical impedance analysis to assess changes in body water compartments after digestive surgery
    Hanaki, Norikazu
    Ishikawa, Masashi
    Nishioka, Masanori
    Kashiwagi, Yutaka
    Miki, Hisashi
    Miyake, Hidenori
    Tashiro, Seiki
    HEPATO-GASTROENTEROLOGY, 2006, 53 (71) : 723 - 729
  • [7] Bioelectrical impedance analysis; a new method to evaluate lymphoedema, fluid status, and tissue damage after gynaecological surgery - A systematic review
    Asklof, Madeleine
    Kjolhede, Preben
    Wodlin, Ninnie Borendal
    Nilsson, Lena
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2018, 228 : 111 - 119
  • [8] Bioelectrical impedance analysis for assessment of fluid status and body composition in neonates-the good, the bad and the unknown
    Lingwood, B. E.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2013, 67 : S28 - S33
  • [9] Assessment of Fluid and Nutritional Status Using Multifrequency Bioelectrical Impedance Analysis in Peritoneal Dialysis Patients
    Hyun, Seung-Hyea
    Choi, Ji-Young
    Cho, Jang-Hee
    Park, Sun-Hee
    Kim, Chan-Duck
    Kim, Yong-Lim
    BLOOD PURIFICATION, 2014, 37 (02) : 152 - 162
  • [10] Postoperative Changes in Body Composition After Pancreaticoduodenectomy Using Multifrequency Bioelectrical Impedance Analysis
    Mikamori, Manabu
    Miyamoto, Atsushi
    Asaoka, Tadafumi
    Maeda, Sakae
    Hama, Naoki
    Yamamoto, Kazuyoshi
    Hirao, Motohiro
    Ikeda, Masataka
    Sekimoto, Mitsugu
    Doki, Yuichiro
    Mori, Masaki
    Nakamori, Shoji
    JOURNAL OF GASTROINTESTINAL SURGERY, 2016, 20 (03) : 611 - 618