Rapid multi-residue method for the quantitative determination and confirmation of glucocorticosteroids in bovine milk using liquid chromatography-electrospray ionization-tandem mass spectrometry

被引:47
|
作者
McDonald, Mark
Granelli, Kristina
Sjoberg, Pernilla
机构
[1] Cent Meat Control Lab, Dept Agr, Celbridge, Kildare, Ireland
[2] Natl Food Adm Toxicol Lab, Chem Div 1, SE-75126 Uppsala, Sweden
关键词
synthetic glucocorticosteroids; dexamethasone; betamethasone; prednisolone; 6; alpha-methylprednisolone; flumethasone; milk; liquid chromatography; tandem mass spectrometry; validation; CORTICOSTEROID RESIDUES; URINE; DEXAMETHASONE; EXTRACTION; SAMPLES;
D O I
10.1016/j.aca.2007.01.075
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dexamethasone, betamethasone and prednisolone are synthetic glucocorticosteroids authorised for therapeutic use in bovine animals within the European Union. Dexamethasone and betamethasone are used mainly for the treatment of metabolic and inflammatory diseases. Prednisolone is used to treat bovine mastitis. Maximum residue limits (MRLs) of 0.3 mu g kg(-1) for both dexamethasone and betamethasone and 6.0 mu g kg(-1) for prednisolone in bovine milk have been established. 6 alpha-Methylprednisolone and flumethasone are not authorised for use in bovine animals and are completely banned in bovine milk. The proposed method is based on deprotenisation of milk using 20% (w/v) trichloroacetic acid. Samples are filtered using glass microfibre filters and subject to clean-up using OASIS HLB solid phase extraction. Separation was achieved on a Hypercarb 100 mm x 2.1 mm x 5 mu m column. Mobile phase was: 90/10 acetonitrile/0.1% formic acid in water; flow rate was 600 mu L min(-1). The method allowed the rapid identification and confirmation of the five glucocorticosteroids according to the criteria laid down in Commission Decision 2002/657/EC. Matrix calibration curves for all compounds were linear in the interval 0.0MRL to 2.0MRL with a correlation coefficient (r(2)) higher than 0.96. Relative recoveries ranged from 97% for betamethasone to 111% for prednisolone. Precision at the MRL ranged from 3.8% for prednisolone to 13.8% for betamethasone. Decision limits, CC alpha, and detection capability, CC beta have been calculated for all compounds. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:20 / 25
页数:6
相关论文
共 50 条
  • [41] Multi-residue determination of veterinary drugs in milk by ultra-high-pressure liquid chromatography-tandem mass spectrometry
    Aguilera-Luiz, M. M.
    Martinez Vidal, Jose Luis
    Romero-Gonzalez, Roberto
    Garrido Frenich, Antonia
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1205 (1-2) : 10 - 16
  • [42] Simultaneous Determination of 12 Toxic Alkaloids in Urine and Gastric Juice Using Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry
    Zhang Chun-Hua
    Wu Hui-Qin
    Huang Xiao-Lan
    Zhu Zhi-Xin
    Huang Fang
    Lin Xiao-Shan
    Luo Hui-Tai
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (06) : 862 - 869
  • [43] Steroid and steroid glucuronide profiles in urine during pregnancy determined by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Jantti, Sirkku E.
    Hartonen, Minna
    Hilvo, Mika
    Nygren, Heli
    Hyotylainen, Tuulia
    Ketola, Raimo A.
    Kostiainen, Risto
    ANALYTICA CHIMICA ACTA, 2013, 802 : 56 - 66
  • [44] Non-Invasive Monitoring of Corticosterone Levels in Mouse Urine with Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry
    Howe-Wittek, Laura
    Kroschk, Paul
    Nieschalke, Kai
    Rawel, Harshadrai M.
    Kraemer, Stephanie
    Raila, Jens
    MOLECULES, 2024, 29 (22):
  • [45] Determination of Furaltadone and Nifursol Residues in Poultry Eggs by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry
    Barbosa, Jorge
    Freitas, Andreia
    Mourao, Jose Luis
    Noronha da Silveira, Maria Irene
    Ramos, Fernando
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2012, 60 (17) : 4227 - 4234
  • [46] A sensitive, fast and accurate liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-MS/MS) method for the pharmacokinetic study of cyclobenzaprine tablets
    Li, Jian-Chun
    Chen, Fei-Hu
    Zhang, Jun-Dong
    Dong, Hai-Jun
    Gao, Shu
    AFRICAN JOURNAL OF PHARMACY AND PHARMACOLOGY, 2012, 6 (10): : 708 - 716
  • [47] Screening and Quantitative Confirmatory Method for the Analysis of Glucocorticoids in Bovine Milk Using Liquid Chromatography-Tandem Mass Spectrometry
    Malone, Edward M.
    Elliott, Chris T.
    Kennedy, David G.
    Regan, Liam
    JOURNAL OF AOAC INTERNATIONAL, 2010, 93 (05) : 1656 - 1665
  • [48] Determination of mycotoxins in bovine milk by liquid chromatography tandem mass spectrometry
    Sorensen, LK
    Elbæk, TH
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 820 (02): : 183 - 196
  • [49] Using precursor ion scan of 184 with liquid chromatography-electrospray ionization-tandem mass spectrometry for concentration normalization in cellular lipidomic studies
    Chao, Hsi-Chun
    Chen, Guan-Yuan
    Hsu, Lih-Ching
    Liao, Hsiao-Wei
    Yang, Sin-Yu
    Wang, San-Yuan
    Li, Yu-Liang
    Tang, Sung-Chun
    Tseng, Yufeng Jane
    Kuo, Ching-Hua
    ANALYTICA CHIMICA ACTA, 2017, 971 : 68 - 77
  • [50] Simultaneous determination of 38 phosphodiestrase-5 inhibitors in illicit erectile dysfunction products by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Lee, Eung-Sun
    Lee, Ji Hyun
    Han, Kyoung Moon
    Kim, Ji Won
    Hwang, In Sun
    Cho, Sooyeul
    Han, Soon Young
    Kim, Jinho
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 83 : 171 - 178