Rapid multi-residue method for the quantitative determination and confirmation of glucocorticosteroids in bovine milk using liquid chromatography-electrospray ionization-tandem mass spectrometry

被引:47
作者
McDonald, Mark
Granelli, Kristina
Sjoberg, Pernilla
机构
[1] Cent Meat Control Lab, Dept Agr, Celbridge, Kildare, Ireland
[2] Natl Food Adm Toxicol Lab, Chem Div 1, SE-75126 Uppsala, Sweden
关键词
synthetic glucocorticosteroids; dexamethasone; betamethasone; prednisolone; 6; alpha-methylprednisolone; flumethasone; milk; liquid chromatography; tandem mass spectrometry; validation; CORTICOSTEROID RESIDUES; URINE; DEXAMETHASONE; EXTRACTION; SAMPLES;
D O I
10.1016/j.aca.2007.01.075
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dexamethasone, betamethasone and prednisolone are synthetic glucocorticosteroids authorised for therapeutic use in bovine animals within the European Union. Dexamethasone and betamethasone are used mainly for the treatment of metabolic and inflammatory diseases. Prednisolone is used to treat bovine mastitis. Maximum residue limits (MRLs) of 0.3 mu g kg(-1) for both dexamethasone and betamethasone and 6.0 mu g kg(-1) for prednisolone in bovine milk have been established. 6 alpha-Methylprednisolone and flumethasone are not authorised for use in bovine animals and are completely banned in bovine milk. The proposed method is based on deprotenisation of milk using 20% (w/v) trichloroacetic acid. Samples are filtered using glass microfibre filters and subject to clean-up using OASIS HLB solid phase extraction. Separation was achieved on a Hypercarb 100 mm x 2.1 mm x 5 mu m column. Mobile phase was: 90/10 acetonitrile/0.1% formic acid in water; flow rate was 600 mu L min(-1). The method allowed the rapid identification and confirmation of the five glucocorticosteroids according to the criteria laid down in Commission Decision 2002/657/EC. Matrix calibration curves for all compounds were linear in the interval 0.0MRL to 2.0MRL with a correlation coefficient (r(2)) higher than 0.96. Relative recoveries ranged from 97% for betamethasone to 111% for prednisolone. Precision at the MRL ranged from 3.8% for prednisolone to 13.8% for betamethasone. Decision limits, CC alpha, and detection capability, CC beta have been calculated for all compounds. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:20 / 25
页数:6
相关论文
共 21 条
[1]  
[Anonymous], OFF J EUR COMM
[2]   Multi-residue extraction-purification procedure for corticosteroids in biological samples for efficient control of their misuse in livestock production [J].
Antignac, JP ;
Le Bizec, B ;
Monteau, F ;
Poulain, F ;
Andre, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 757 (01) :11-19
[3]  
ANTIGNAC JP, 2004, CHROMATOGRAPHIA, P59
[4]   Determination of flumethasone in calf urine and serum by liquid chromatography-tandem mass spectrometry [J].
Brambilla, G ;
Buiarelli, F ;
Cartoni, GP ;
Coccioli, F ;
Colamonici, C ;
Fagiolo, A ;
Giannini, C ;
Neri, B .
JOURNAL OF CHROMATOGRAPHY B, 2001, 755 (1-2) :265-278
[5]   Quantitative determination of dexamethasone in bovine milk by liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry [J].
Cherlet, M ;
De Baere, S ;
De Backer, P .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (01) :57-65
[6]  
DeWasch K., 1994, ANALYST, V119, P2557
[7]   Accelerated solvent extraction and liquid chromatography-tandem mass spectrometry quantitation of corticosteroid residues in bovine liver [J].
Draisci, R ;
Marchiafava, C ;
Palleschi, L ;
Cammarata, P ;
Cavalli, S .
JOURNAL OF CHROMATOGRAPHY B, 2001, 753 (02) :217-223
[8]  
*EEC, 1999, OFF J EUR COMM, pL315
[9]  
*EEC, 1990, OFF J EUR COMM, pL224
[10]   DEXAMETHASONE BOVINE PHARMACOKINETICS [J].
GAIGNAGE, P ;
LOGNAY, G ;
BOSSON, D ;
VERTONGEN, D ;
DREZE, P ;
MARLIER, M ;
SEVERIN, M .
EUROPEAN JOURNAL OF DRUG METABOLISM AND PHARMACOKINETICS, 1991, 16 (03) :219-221