Accuracy of an oscillometric blood pressure monitor in anesthetized pigs

被引:7
作者
Reed, Rachel [1 ]
Barletta, Michele [1 ]
Grimes, Janet [2 ]
Mumaw, Jennifer [3 ]
Park, Hea Jin [4 ]
Giguere, Steeve [1 ]
Azain, Michael [5 ]
Fang, Xi [4 ]
Quandt, Jane [2 ]
机构
[1] Univ Georgia, Coll Vet Med, Dept Large Anim Med, Athens, GA 30602 USA
[2] Univ Georgia, Coll Vet Med, Dept Small Anim Med & Surg, Athens, GA 30602 USA
[3] Univ Georgia, Coll Vet Med, Dept Populat Hlth, Athens, GA 30602 USA
[4] Univ Georgia, Coll Family & Consumer Sci, Dept Foods & Nutr, Athens, GA 30602 USA
[5] Univ Georgia, Coll Agr & Environm Sci, Dept Anim & Dairy Sci, Athens, GA 30602 USA
关键词
pig; blood pressure; oscillometric; anesthesia; monitoring; SURGIVET V9203; DOGS; ISOFLURANE; CATS; DEFINITION; GUIDELINES; AGREEMENT;
D O I
10.1177/0023677218763686
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The purpose of this study is to evaluate the accuracy of an oscillometric blood pressure monitor in anesthetized pigs. Invasive blood pressure (IBP) and noninvasive blood pressure (NIBP) measurements were taken using a DRE Waveline Pro multiparameter monitor at four different time points in 17 pigs undergoing injectable anesthesia. NIBP measurements were taken on both the thoracic and pelvic limbs. Bland Altman analysis was used to assess agreement between methods and a linear mixed-effects model was used to evaluate the effect of cuff position and blood pressure on bias. Invasive systolic arterial pressure (SAP) ranged between 112 and 161mmHg (meanSD: 138.813.3; median: 139.5). Invasive diastolic arterial pressure (DAP) ranged between 60 and 104mmHg (meanSD: 86.0 +/- 9.1; median: 87.0). Invasive mean arterial pressure (MAP) ranged between 79 and 121mmHg (mean +/- SD: 103.2 +/- 9.3; median 103.0). Only the diastolic and mean measurements obtained from the pelvic limb met criteria outlined by the American College of Internal Medicine for required accuracy of NIBP monitors. Bias was significantly higher in the thoracic limb in comparison to the pelvic limb and was significantly higher at blood pressures above median. In general, NIBP measurements underestimated IBP measurements. In conclusion, the use of the DRE Waveline Pro to assess NIBP in anesthetized pigs may be useful in monitoring trends in mean and diastolic blood pressure and is most accurate when used on the pelvic limb.
引用
收藏
页码:490 / 496
页数:7
相关论文
共 31 条
[1]  
Aarnes TK, 2012, CAN VET J, V53, P881
[2]   Comparison between invasive blood pressure and a non-invasive blood pressure monitor in anesthetized sheep [J].
Almeida, Daniel ;
Barletta, Michele ;
Mathews, Lindsey ;
Graham, Lynelle ;
Quandt, Jane .
RESEARCH IN VETERINARY SCIENCE, 2014, 97 (03) :582-586
[3]  
[Anonymous], 2009, ANSIAAMIISO81602
[4]   Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive? [J].
Araghi, Ali ;
Bander, Joseph J. ;
Guzman, Jorge A. .
CRITICAL CARE, 2006, 10 (02)
[5]   Blood Pressure Monitoring for the Anesthesiologist: A Practical Review [J].
Bartels, Karsten ;
Esper, Stephen A. ;
Thiele, Robert H. .
ANESTHESIA AND ANALGESIA, 2016, 122 (06) :1866-1879
[6]   The pig as an animal model for human pathologies: A proteomics perspective [J].
Bassols, Anna ;
Costa, Cristina ;
David Eckersall, P. ;
Osada, Jesus ;
Sabria, Josefa ;
Tibau, Joan .
PROTEOMICS CLINICAL APPLICATIONS, 2014, 8 (9-10) :715-731
[7]   DOPPLER ULTRASONOGRAPHIC, OSCILLOMETRIC SPHYGMOMANOMETRIC, AND PHOTOPLETHYSMOGRAPHIC TECHNIQUES FOR NONINVASIVE BLOOD-PRESSURE MEASUREMENT IN ANESTHETIZED CATS [J].
BINNS, SH ;
SISSON, DD ;
BUOSCIO, DA ;
SCHAEFFER, DJ .
JOURNAL OF VETERINARY INTERNAL MEDICINE, 1995, 9 (06) :405-414
[8]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[9]   Ischaemic distal limb necrosis and Klebsiella pneumoniae infection associated with arterial catheterisation in a cat [J].
Bowlt, Kelly L. ;
Bortolami, Elisa ;
Harley, Ross ;
Murison, Pamela ;
Wallace, Adrian .
JOURNAL OF FELINE MEDICINE AND SURGERY, 2013, 15 (12) :1165-1168
[10]  
Brown S, 2007, J VET INTERN MED, V21, P542, DOI 10.1892/0891-6640(2007)21[542:GFTIEA]2.0.CO