Apparatus for measurements of physiological parameters in fish

被引:0
|
作者
Radovan, S
Vidmar, A
Suhadolnik, A
机构
[1] Clin Ctr Ljubljana, Clin Dept Cardiol, Ljubljana 1000, Slovenia
[2] ITIS DOO, Ctr Implantable Technol & Sensors, Ljubljana 1000, Slovenia
[3] Fac Mech Engn, Ljubljana 1000, Slovenia
来源
INFORMACIJE MIDEM-JOURNAL OF MICROELECTRONICS ELECTRONIC COMPONENTS AND MATERIALS | 2004年 / 34卷 / 02期
关键词
fish physiology; in vivo experiments; apparatus; ECG; water flow pressure; gill movement;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A special apparatus for simultaneous recording of a fish gill movement, ECG and water flow through a fish mouth was designed, developed and experimentally tested. A pair of single channel force transducers with linear dependence of the output voltage upon the load 0.5 mV/mN over the nominal range of 0-70 mN at a bridge excitation of 5V was used for recording the curves of gill movements. Wires fixed with the fishing hooks into the fish body and on the other side connected to the amplifier were used for ECG recordings. A pressure transducer recorded a water flow through a fish mouth. We recommend our set up as a simple and useful tool for recording the described physiological parameters in experiments with fish.
引用
收藏
页码:118 / 120
页数:3
相关论文
共 45 条
  • [1] Automated apparatus for gas solubility measurements
    Fonseca, I. M. A.
    Almeida, J. P. B.
    Fachada, H. C.
    JOURNAL OF CHEMICAL THERMODYNAMICS, 2007, 39 (10) : 1407 - 1411
  • [2] Improved Design of a Tubular Electrochemical Membrane Apparatus and a Method for Calculating the Apparatus Parameters
    S. V. Kovalev
    O. A. Kovaleva
    Chemical and Petroleum Engineering, 2022, 58 : 179 - 184
  • [3] Improved Design of a Tubular Electrochemical Membrane Apparatus and a Method for Calculating the Apparatus Parameters
    Kovalev, S. V.
    Kovaleva, O. A.
    CHEMICAL AND PETROLEUM ENGINEERING, 2022, 58 (3-4) : 179 - 184
  • [4] The technical possibilities in telemonitoring of physiological parameters
    Bolz A.
    Braecklein M.
    Moor C.
    Gmelin M.
    Herzschrittmachertherapie & Elektrophysiologie, 2005, 16 (3): : 134 - 142
  • [5] A VARIABLE VOLUME APPARATUS FOR THE MEASUREMENTS OF PVTX PROPERTIES OF FLUIDS
    GUO, JX
    ZHAO, ZY
    YIN, JM
    TAN, LC
    FLUID PHASE EQUILIBRIA, 1993, 88 (pt 5) : 151 - 157
  • [6] Do fishways stress fish? Assessment of physiological and hydraulic parameters of rainbow trout navigating a novel W-weir fishway
    Shahabi, Maryam
    Ghomeshi, Mehdi
    Ahadiyan, Javad
    Mohammadian, Takavar
    Katopodis, Christos
    ECOLOGICAL ENGINEERING, 2021, 169
  • [7] Forecasting Technological Parameters of Electrodialysis Apparatus for Solution Separation
    Shestakov, K., V
    Lazarev, S., I
    Khokhlov, P. A.
    Lazarev, D. S.
    CHEMICAL AND PETROLEUM ENGINEERING, 2022, 58 (1-2) : 111 - 118
  • [8] Geophysical technology for determining the ground parameters (methods and apparatus)
    Bondarenko, M. S.
    Yevstakhevych, Z. M.
    Kulyk, V. V.
    Diachenko, S. I.
    Kamilova, O. V.
    GEOFIZICHESKIY ZHURNAL-GEOPHYSICAL JOURNAL, 2023, 45 (01): : 72 - 86
  • [9] Forecasting Technological Parameters of Electrodialysis Apparatus for Solution Separation
    K. V. Shestakov
    S. I. Lazarev
    P. A. Khokhlov
    D. S. Lazarev
    Chemical and Petroleum Engineering, 2022, 58 : 111 - 118
  • [10] Physiological Mechanisms of Acute Upper Thermal Tolerance in Fish
    Ern, Rasmus
    Andreassen, Anna H.
    Jutfelt, Fredrik
    PHYSIOLOGY, 2023, 38 (03) : 141 - 158