Intra-rater and inter-rater reliability of cervical active range of movement in young asymptomatic adults using inertial sensors

被引:11
作者
Anoro-Hervera, Alejandro [1 ]
Lafuente-Perez, Adrian [1 ]
Navarro-Fernandez, Gonzalo [1 ,2 ]
Munoz-Garcia, Daniel [3 ]
Lerma-Lara, Sergio [1 ,3 ]
Beltran-Alacreu, Hector [1 ,2 ]
机构
[1] Univ Autonoma Madrid, Ctr Super Estudios Univ La Salle, Dept Fisioterapia, Madrid, Spain
[2] Univ Autonoma Madrid, Ctr Super Estudios Univ La Salle, CranioSPain Res Grp, Madrid, Spain
[3] Univ Autonoma Madrid, Ctr Super Estudios Univ La Salle, Mot Brains Res Grp, Inst Neurociencias & Ciencias Movimiento, Madrid, Spain
关键词
Cervical aROM; inertial sensor; reliability; diagnosis; assessment; SAMPLE-SIZE REQUIREMENTS; NECK-DISABILITY-INDEX; CORRELATION-COEFFICIENT; SMARTPHONE APPLICATIONS; CONCURRENT VALIDITY; MOTION; SPINE; PAIN; SYSTEM; HEAD;
D O I
10.1080/17434440.2019.1696675
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives: Current literature is scarce about the use of an inertial sensor to measure cervical active range of motion (aROM). The objective of the present study is to determine inter- and intra-reliability in the measurement of cervical aROM using inertial sensors in asymptomatic individuals. Materials and methods: Twenty asymptomatic individuals participated in the study. Two different physiotherapists measured each participant for cervical aROM (6 movements). The sequence of movements and the explanations given were standardized. The rater's order of measurement was randomized. Results: For the intra-rater results, the intraclass correlation coefficient (ICC) values for all cervical movements were good for Rater A (ICC >0.90) and Rater B (ICC >0.90). For the inter-rater results, the ICC values were above 0.75 for all movements, indicating a good level of reliability. Also, values obtained in SEM, MDC90 and LOA indicate good agreement. Conclusion: The data obtained in this study suggest that inertial sensors can be used in clinics due to their high intra- and inter-rater ICC (>0.80). Also, its low economic cost, easy handling, and various utilities make this tool a useful alternative in the measurement of cervical aROM.
引用
收藏
页码:1071 / 1077
页数:7
相关论文
共 59 条
[41]   A technical support tool for joint range of motion determination in functional diagnostics - an inter-rater study [J].
Schiefer, Christoph ;
Kraus, Thomas ;
Ellegast, Rolf P. ;
Ochsmann, Elke .
JOURNAL OF OCCUPATIONAL MEDICINE AND TOXICOLOGY, 2015, 10
[42]   Standardized initial head position in cervical range-of-motion assessment: Reliability and error analysis [J].
Solinger, AB ;
Chen, J ;
Lantz, CA .
JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2000, 23 (01) :20-26
[43]   To What Degree Does Active Cervical Range of Motion Differ Between Patients With Neck Pain, Patients With Whiplash, and Those Without Neck Pain? A Systematic Review and Meta-Analysis [J].
Stenneberg, Martijn S. ;
Rood, Michiel ;
de Bie, Rob ;
Schmitt, Maarten A. ;
Cattrysse, Erik ;
Scholten-Peeters, Gwendolijne G. .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2017, 98 (07) :1407-1434
[44]   Cervical spine ROM measurements: optimizing the testing protocol by using a 3D ultrasound-based motion analysis system [J].
Strimpakos, N ;
Sakellari, V ;
Gioftsos, G ;
Papathanasiou, M ;
Brountzos, E ;
Kelekis, D ;
Kapreli, E ;
Oldham, J .
CEPHALALGIA, 2005, 25 (12) :1133-1145
[45]   Normal Values for Cervical Range of Motion [J].
Swinkels, Raymond A. H. M. ;
Swinkels-Meewisse, Ilse E. J. C. M. .
SPINE, 2014, 39 (05) :362-367
[46]   Do inertial sensors represent a viable method to reliably measure cervical spine range of motion? [J].
Theobald, Peter S. ;
Jones, Michael D. ;
Williams, Jonathan M. .
MANUAL THERAPY, 2012, 17 (01) :92-96
[47]   Validity study for the cervical range of motion device used for lateral flexion in patients with neck pain [J].
Tousignant, M ;
Duclos, E ;
Laflèche, S ;
Mayer, A ;
Tousignant-Laflamme, Y ;
Brosseau, L ;
O'Sullivan, JP .
SPINE, 2002, 27 (08) :812-817
[48]   Reliability and criterion validity of two applications of the iPhone™ to measure cervical range of motion in healthy participants [J].
Tousignant-Laflamme, Yannick ;
Boutin, Nicolas ;
Dion, Alexandre M. ;
Vallee, Carol-Anne .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2013, 10
[49]  
VERNON H, 1991, J MANIP PHYSIOL THER, V14, P409
[50]   The Neck Disability Index: State-of-the-art, 1991-2008 [J].
Vernon, Howard .
JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2008, 31 (07) :491-502