Intra-rater and inter-rater reliability of cervical active range of movement in young asymptomatic adults using inertial sensors

被引:11
作者
Anoro-Hervera, Alejandro [1 ]
Lafuente-Perez, Adrian [1 ]
Navarro-Fernandez, Gonzalo [1 ,2 ]
Munoz-Garcia, Daniel [3 ]
Lerma-Lara, Sergio [1 ,3 ]
Beltran-Alacreu, Hector [1 ,2 ]
机构
[1] Univ Autonoma Madrid, Ctr Super Estudios Univ La Salle, Dept Fisioterapia, Madrid, Spain
[2] Univ Autonoma Madrid, Ctr Super Estudios Univ La Salle, CranioSPain Res Grp, Madrid, Spain
[3] Univ Autonoma Madrid, Ctr Super Estudios Univ La Salle, Mot Brains Res Grp, Inst Neurociencias & Ciencias Movimiento, Madrid, Spain
关键词
Cervical aROM; inertial sensor; reliability; diagnosis; assessment; SAMPLE-SIZE REQUIREMENTS; NECK-DISABILITY-INDEX; CORRELATION-COEFFICIENT; SMARTPHONE APPLICATIONS; CONCURRENT VALIDITY; MOTION; SPINE; PAIN; SYSTEM; HEAD;
D O I
10.1080/17434440.2019.1696675
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives: Current literature is scarce about the use of an inertial sensor to measure cervical active range of motion (aROM). The objective of the present study is to determine inter- and intra-reliability in the measurement of cervical aROM using inertial sensors in asymptomatic individuals. Materials and methods: Twenty asymptomatic individuals participated in the study. Two different physiotherapists measured each participant for cervical aROM (6 movements). The sequence of movements and the explanations given were standardized. The rater's order of measurement was randomized. Results: For the intra-rater results, the intraclass correlation coefficient (ICC) values for all cervical movements were good for Rater A (ICC >0.90) and Rater B (ICC >0.90). For the inter-rater results, the ICC values were above 0.75 for all movements, indicating a good level of reliability. Also, values obtained in SEM, MDC90 and LOA indicate good agreement. Conclusion: The data obtained in this study suggest that inertial sensors can be used in clinics due to their high intra- and inter-rater ICC (>0.80). Also, its low economic cost, easy handling, and various utilities make this tool a useful alternative in the measurement of cervical aROM.
引用
收藏
页码:1071 / 1077
页数:7
相关论文
共 59 条
[1]   Reliability of the Spin-T cervical goniometer in measuring cervical range of motion in an asymptomatic Indian population [J].
Agarwal, S ;
Allison, GT ;
Singer, KP .
JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2005, 28 (07) :487-492
[2]   Validation of the Spanish Version of the Neck Disability Index [J].
Andrade Ortega, Juan Alfonso ;
Delgado Martinez, Alberto Damian ;
Almecija Ruiz, Remedios .
SPINE, 2010, 35 (04) :E114-E118
[3]  
[Anonymous], STAT METHODS MED RES
[4]   Interobserver reliability of neck-mobility measurement by means of the flock-of-birds electromagnetic tracking system [J].
Assink, N ;
Bergman, GJD ;
Knoester, B ;
Winters, JC ;
Dijkstra, PU ;
Postema, K .
JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2005, 28 (06) :408-413
[5]   Assessment of the cervical range of motion over time, differences between results of the Flock of Birds and the EDI-320: A comparison between an electromagnetic tracking system and an electronic inclinometer [J].
Assink, Nienke ;
Bergman, Gert J. D. ;
Knoester, Bianca ;
Winters, Jan C. ;
Dijkstra, Pieter U. .
MANUAL THERAPY, 2008, 13 (05) :450-455
[6]   Validity and Between-Day Reliability of the Cervical Range of Motion (CROM) Device [J].
Audette, Isabel ;
Dumas, Jean-Pierre ;
Cote, Julie N. ;
De Serres, Sophie J. .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2010, 40 (05) :318-323
[7]   Neck motion kinematics: an inter-tester reliability study using an interactive neck VR assessment in asymptomatic individuals [J].
Bahat, Hilla Sarig ;
Sprecher, Elliot ;
Sela, Itamar ;
Treleaven, Julia .
EUROPEAN SPINE JOURNAL, 2016, 25 (07) :2139-2148
[8]  
Beltran-Alacreu H, 2019, FISIOTERAPIA, V41, P123, DOI [10.1016/j. ft.2019.02.008, DOI 10.1016/J.FT.2019.02.008]
[9]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[10]  
Blanpied Peter R, 2017, J Orthop Sports Phys Ther, V47, pA1, DOI 10.2519/jospt.2017.0302