Dynamic Stray Current Evaluations on Cut-and-Cover Sections of DC Metro Systems

被引:69
|
作者
Charalambous, Charalambos A. [1 ,3 ]
Aylott, Pete [2 ,4 ]
机构
[1] Univ Cyprus, Dept Elect & Comp Engn, CY-1687 Nicosia, Cyprus
[2] Intertek, Manchester M1 7DP, Lancs, England
[3] Univ Manchester, Sch Elect & Elect Engn, Elect Energy & Power Syst Grp, Manchester M13 9PL, Lancs, England
[4] CAPCIS Ltd, Manchester, Lancs, England
关键词
Cut-and-cover systems; DC transit systems; dynamic modeling; stray current design and control; TRANSIT SYSTEMS;
D O I
10.1109/TVT.2014.2304522
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The tunneling construction in underground DC Metro Systems is mainly based on the bored tunnel method and the cut-and-cover method. Therefore, the stray current assessments and mitigation actions should be tailored according to which method of tunnel construction is used. This paper presents a topologically accurate model for assessing the dynamic stray current picture in cut-and-cover sections of DC metro systems. The dynamic stray current evaluation can provide an indication to the extent of the corrosion problem in the supporting and third-party infrastructures of the system. In this paper, the dynamic evaluations are based on a combination of various ideal and realistic train operation scenarios.
引用
收藏
页码:3530 / 3538
页数:9
相关论文
共 50 条
  • [31] Diffusion Model of DC Dynamic Stray Current in Layered Soil
    Liu W.
    Yin Y.
    Pan W.
    Yang L.
    Zhang H.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2021, 36 (23): : 4864 - 4873
  • [32] Effects of earthing systems on stray current for corrosion and safety behaviour in practical metro systems
    Alamuti, M. M.
    Nouri, H.
    Jamali, S.
    IET ELECTRICAL SYSTEMS IN TRANSPORTATION, 2011, 1 (02) : 69 - 79
  • [33] The investigation of Cut-and-cover, top-down construction method for a metro underground station; case study: 'Naghsh-e-Jahan Metro Station, Esfahan, Iran'
    Cambyse, Behniya
    Amir, Tavallaie Nejad
    Hossein, Salari Rad
    JOURNAL OF MATERIALS AND ENGINEERING STRUCTURES, 2021, 8 (04): : 491 - 504
  • [34] Research on corrosion rate assessment of buried pipelines under dynamic metro stray current
    Du, Yanxia
    Qin, Huimin
    Liu, Jie
    Tang, Dezhi
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2021, 72 (06): : 1038 - 1050
  • [35] Modeling and Influencing Factors Analysis of Dynamic Potential Distribution Caused by Metro Stray Current
    Ni Y.
    Zeng X.
    Yu K.
    Cheng X.
    Tang Y.
    Zhuo C.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (23): : 9059 - 9071
  • [36] Evaluation and Control of Stray Current in DC-Electrified Railway Systems
    Zaboli, Aydin
    Vahidi, Behrooz
    Yousefi, Sasan
    Hosseini-Biyouki, Mohammad Mahdi
    IEEE TRANSACTIONS ON VEHICULAR TECHNOLOGY, 2017, 66 (02) : 974 - 980
  • [37] RECOMMENDED MAINTENANCE PRACTICES FOR STRAY CURRENT CORROSION ON DC ELECTRIFIED SYSTEMS
    Zan, Kelvin
    Mawley, Vish
    Ramos, Moises
    Singh, Sarvjit
    PROCEEDINGS OF THE ASME JOINT RAIL CONFERENCE, 2014, 2014,
  • [38] Stray Current Calculation and Monitoring in DC Mass-Transit Systems
    Charalambous, Charalambos A.
    Aylott, Pete
    Buxton, David
    IEEE VEHICULAR TECHNOLOGY MAGAZINE, 2016, 11 (02): : 24 - 31
  • [39] DC Stray Current in Rail Transit Systems and Cathodic Protection [History]
    Paul D.
    Paul, Dev, 2016, Institute of Electrical and Electronics Engineers Inc., United States (22) : 8 - 13
  • [40] Accelerated corrosion of pipeline steel under dynamic DC stray current interference
    Qin, Huimin
    Du, Yanxia
    Lu, Minxu
    Liu, Jie
    Zhu, Xiangjian
    CORROSION ENGINEERING SCIENCE AND TECHNOLOGY, 2020, 55 (08) : 670 - 680