Reliability of fibres in solid-phase microextraction for routine analysis of the headspace of aromatic and medicinal plants

被引:52
作者
Bicchi, Carlo [1 ]
Cordero, Chiara [1 ]
Liberto, Erica [1 ]
Sgorbini, Barbara [1 ]
Rubiolo, Patrizia [1 ]
机构
[1] Univ Turin, Dipartimento Sci & Tecnol Farmaco, I-10125 Turin, Italy
关键词
headspace solid phase microextraction; PDMS; CAR/DVB/PDMS; repeatability; fibre-life; chamomile flower heads; sage leaves;
D O I
10.1016/j.chroma.2007.02.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This article evaluates the HS-SPME recovery repeatability, intermediate precision and their performance over time when applied to HS-SPME sampling for quality control of medicinal and aromatic plants. Experiments were carried out on two sets of fibres coated with two different coatings and belonging to different lots (i.e 100 mu m polyclimethylsyloxane (PDMS) and Carboxen/divinylbenzene/PDMS 50/30 mu m, 1: 1 cm (CAR/DVB/PDMS)) and on chamomile (Matricaria chamomilla L.), sage (Salvia lavandulifolia Vahl.) and a standard solution containing 3-hexanol, isoamyl acetate, 1,8-cineole and menthol in diisobutyl phthalate. The performance of each set of fibres was evaluated by determining a group of complementary statistical parameters including: (i) repeatability of the absolute areas of each marker from each matrix with each fibre; (ii) intra-fibre repeatability of the total absolute areas of the markers of each matrix obtained with each fibre of each set; (iii) inter-fibre intermediate precision of the total absolute areas of the markers of each matrix obtained with all fibres of each set; and (iv) analysis of variance by one-way ANOVA with Fisher and Tukey tests. The influence of the number of analyses on fibre effectiveness (fibre life-time) was studied by linear regression analysis (LRA). The results proved that HS-SPME can successfully be used for routine control analysis of aromatic ad medicinal plants since both types of fibres showed good repeatability and intermediate precision of analytes recovery and consistency over time. Unlike data previously reported by other authors, CAR/DVB/PDMS coated fibres gave better results than those coated with PDMS. The fibre-life seemed mainly to be influenced by the number and conditions of samplings and nature of the matrix investigated. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 149
页数:12
相关论文
共 20 条
  • [11] Preparation and characteristics of sol-gel-coated calix[4]arene fiber for solid-phase microextraction
    Li, XJ
    Zeng, ZR
    Gao, SZ
    Li, HB
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1023 (01) : 15 - 25
  • [12] Headspace solid-phase microextraction analysis of aroma compounds in vinegar -: Validation study
    Marín, RN
    Mejías, RC
    Moreno, WDG
    Rowe, FG
    Barroso, CG
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 967 (02) : 261 - 267
  • [13] Optimisation of headspace solid-phase microextraction for analysis of aromatic compounds in vinegar
    Mejías, RC
    Marín, RN
    Moreno, MD
    Barroso, CG
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 953 (1-2) : 7 - 15
  • [14] Headspace solid-phase microextraction of sulphides and disulphides using Carboxen-polydimethylsiloxane fibers in the analysis of wine aroma
    Mestres, M
    Sala, C
    Martí, MP
    Busto, O
    Guasch, J
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 835 (1-2) : 137 - 144
  • [15] Solid phase microextraction of volatile organic compounds using carboxen-polydimethylsiloxane fibers
    Popp, P
    Paschke, A
    [J]. CHROMATOGRAPHIA, 1997, 46 (7-8) : 419 - 424
  • [16] Headspace-solid-phase microextraction fast GC in combination with principal component analysis as a tool to classify different chemotypes of chamomile flower-heads (Matricaria recutita L.)
    Rubiolo, Patrizia
    Belliardo, Flavio
    Cordero, Chiara
    Liberto, Erica
    Sgorbini, Barbara
    Bicchi, Carlo
    [J]. PHYTOCHEMICAL ANALYSIS, 2006, 17 (04) : 217 - 225
  • [17] From CGC-MS to MS-based analytical decision makers
    Sandra, P
    David, F
    Tienpont, B
    [J]. CHROMATOGRAPHIA, 2004, 60 (Suppl 1) : S299 - S302
  • [18] High-performance polyethylene glycol-coated solid-phase microextraction fibers using sol-gel technology
    Wang, ZY
    Xiao, CH
    Wu, CY
    Han, HM
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 893 (01) : 157 - 168
  • [19] HEADSPACE SOLID-PHASE MICROEXTRACTION
    ZHANG, ZY
    PAWLISZYN, J
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (14) : 1843 - 1852
  • [20] Optimization of solid-phase microextraction conditions for gas chromatographic determination of ethanol and other volatile compounds in blood
    Zuba, D
    Parczewski, A
    Reichenbächer, M
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (01): : 75 - 82