Flow-induced noise analysis for natural gas manifolds using LES and FW-H hybrid method

被引:32
作者
Han, Tao [1 ]
Wang, Lei [1 ]
Cen, Kang [1 ]
Song, Bin [2 ]
Shen, Ruiqing [3 ]
Liu, Hongbo [1 ]
Wang, Qingsheng [3 ]
机构
[1] Southwest Petr Univ, Sch Civil Engn & Architecture, Chengdu 610500, Sichuan, Peoples R China
[2] Harbin Inst Technol, Sch Architecture, Harbin 150090, Heilongjiang, Peoples R China
[3] Texas A&M Univ, Artie McFerrin Dept Chem Engn, Mary Kay OConnor Proc Safety Ctr, College Stn, TX 77843 USA
基金
中国国家自然科学基金;
关键词
Natural gas manifolds; Flow-induced noise; Acoustic source characteristics; Impact factors; Noise reduction measures; GREY RELATIONAL ANALYSIS; EQUATION-OF-STATE; VIBRATION;
D O I
10.1016/j.apacoust.2019.107101
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this paper, the flow-induced noise generated by natural gas manifolds is analyzed. A noise experiment is carried out to validate the present numerical model. The characteristics of the flow-induced noise, including sound source distribution, sound directivity and frequency spectra, are investigated numerically. The effects of relevant parameters on overall sound pressure level are also analyzed quantitatively, including gas outlet pressure, inlet velocity, and the section area ratio of distribution pipe to inlet/outlet pipes. The main impact factors are evaluated using the orthogonal experimental design and the grey relational analysis method. Furthermore, proper noise reduction measures are also proposed. The results show that the manifold noise is middle and low frequency noise, and the energy of manifold noise is mainly concentrated in the range of 50-1150 Hz. The peak noise dominantly radiates at the directions of 75-105 along the gas flow. The gas inlet velocity should be controlled below 25 m/s. The optimal section area ratio of distribution pipe to outlet pipes should be below 2, while the section area ratio of distribution pipe to inlet pipes should be greater than 4. Gas inlet velocity and the section area ratio of distribution pipe to outlet pipes are the most important impact factors. In addition, some passive measures like noise absorption cover, and isolation hoods or walls, are recommended to reduce the flowinduced noise. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:12
相关论文
共 28 条
[1]  
[Anonymous], 2007, Z22 GB
[2]  
[Anonymous], 2008, 12348 GB
[3]  
[Anonymous], ANSYS FLUENT SOLV TH
[4]  
Cen K., 2017, MATH PROBL ENG, V2017, P1
[5]  
Editorial Committee of Design Manual for Petroleum and Chemical Engineering, 2010, DES MAN PETR CHEM EN
[6]   A finite element LES for high-Re flow in a short-elbow pipe with undisturbed inlet velocity [J].
Eguchi, Yuzuru ;
Murakami, Takahiro ;
Tanaka, Masaaki ;
Yamano, Hidemasa .
NUCLEAR ENGINEERING AND DESIGN, 2011, 241 (11) :4368-4378
[7]   Using Lee-Kesler equation of state to compute the compressibility factor of CO2-content natural gas [J].
Jia, Wenlong ;
Li, Zhuoran ;
Liao, Kexi ;
Li, Changjun .
JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2016, 34 :650-656
[8]  
Jiang HQ, 2008, DRILL PRODUCT TECHNO, V31, P146
[9]   Grey relational analysis for comparative assessment of different cathode materials in microbial electrolysis cells [J].
Kadier, Abudukeremu ;
Abdeshahian, Peyman ;
Simayi, Yibadatihan ;
Ismail, Manal ;
Hamid, Aidil Abdul ;
Kalil, Mohd Sahaid .
ENERGY, 2015, 90 :1556-1562
[10]   Effect of ultrasonic noise generated by pressure control valves on ultrasonic gas flowmeters [J].
Kang, Woong ;
Lee, Saeng-Hee ;
Lee, Seung-Jun ;
Ha, Young-Cheol ;
Jung, Sung-Soo .
FLOW MEASUREMENT AND INSTRUMENTATION, 2018, 60 :95-104