Major element analysis of natural silicates by laser ablation ICP-MS

被引:50
作者
Humayun, Munir [1 ]
Davis, Fred A. [2 ]
Hirschmann, Marc M. [2 ]
机构
[1] Florida State Univ, Natl High Magnet Field Lab, Dept Earth Ocean & Atmospher Sci, Tallahassee, FL 32310 USA
[2] Univ Minnesota, Dept Geol & Geophys, Minneapolis, MN 55455 USA
基金
美国国家科学基金会;
关键词
PLASMA-MASS SPECTROMETRY; MATRIX-MATCHED CALIBRATION; 193; NM; MINERALS; GLASSES; IRON; MICROANALYSIS; ALUMINUM; HAWAII; RATIO;
D O I
10.1039/c001391a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The complete chemical analysis of natural silicates has previously been accomplished only by combining laser ablation ICP-MS with electron microprobe (EMP) analysis to provide complementary information on major element constituents. Here, we present a method for laser ablation ICP-MS analysis of major elements in silicate glasses and minerals that, when applied using a 193 nm laser system coupled to an ICP-MS, provides precision and accuracy comparable to that of EMP techniques. Replicate analyses of USGS glass reference materials BCR-2G and BHVO-2G have internal precision of 1-4%, and are accurate to better than 5%. Further, the LA-ICP-MS method was applied to volume-averaged analysis of a heterogeneous silicate to yield compositions that are more precise than EMP and more accurate for minor elements, particularly MnO.
引用
收藏
页码:998 / 1005
页数:8
相关论文
共 30 条
[1]   Forensic analysis of float glass using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS): validation of a method [J].
Berends-Montero, Shirly ;
Wiarda, Wim ;
de Joode, Peter ;
van der Peijl, Gerard .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (11) :1185-1193
[2]   Non-matrix matched calibration of major and minor concentrations of Zn and Cu in brass, aluminium and silicate glass using NIR femtosecond laser ablation inductively coupled plasma mass spectrometry [J].
Bian, QZ ;
Garcia, CC ;
Koch, J ;
Niemax, K .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (02) :187-191
[3]   Siderophile element constraints on the formation of metal in the metal-rich chondrites Bencubbin, Weatherford, and Gujba [J].
Campbell, AJ ;
Humayun, M ;
Weisberg, MK .
GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (04) :647-660
[4]   Trace element microanalysis in iron meteorites by laser ablation ICPMS [J].
Campbell, AJ ;
Humayun, M .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :939-946
[5]   The composition of KLB-1 peridotite [J].
Davis, Fred A. ;
Tangeman, Jean A. ;
Tenner, Travis J. ;
Hirschmann, Marc M. .
AMERICAN MINERALOGIST, 2009, 94 (01) :176-180
[6]   Evaluation of infrared femtosecond laser ablation for the analysis of geomaterials by ICP-MS [J].
Freydier, R. ;
Candaudap, F. ;
Poitrasson, F. ;
Arbouet, A. ;
Chatel, B. ;
Dupre, B. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (05) :702-710
[7]   Elemental fractionation during LA-ICP-MS analysis of silicate glasses: implications for matrix-independent standardization [J].
Gaboardi, Mabry ;
Humayun, Munir .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (09) :1188-1197
[8]   Laser ablation inductively coupled plasma mass spectrometry-current shortcomings, practical suggestions for improving performance, and experiments to guide future development [J].
Garcia, Carmen C. ;
Lindner, Helmut ;
Niemax, Kay .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (01) :14-26
[9]   Comparison of 193, 213 and 266 nm laser ablation ICP-MS [J].
Gonzalez, J ;
Mao, XL ;
Roy, J ;
Mao, SS ;
Russo, RE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (09) :1108-1113
[10]   Preliminary characterisation of new glass reference materials (GSA-1G, GSC-1G, GSD-1G and GSE-1G) by laser ablation-inductively coupled plasma-mass spectrometry using 193 nm, 213 nm and 266 nm wavelengths [J].
Guillong, M ;
Hametner, K ;
Reusser, E ;
Wilson, SA ;
Günther, D .
GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2005, 29 (03) :315-331